--- layout: documentation title: TH8320ZW - ZWave --- {% include base.html %} # TH8320ZW Touchscreen Programmable Thermostat This describes the Z-Wave device *TH8320ZW*, manufactured by *Honeywell* with the thing type UID of ```honeywell_th8320zw_00_000```. The device is in the category of *HVAC*, defining Air condition devices, Fans. ![TH8320ZW product image](https://opensmarthouse.org/zwavedatabase/182/image/) The TH8320ZW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Touchscreen Thermostat, precise comfort control, easy to use touch screen display, extra large backlit display. ### Inclusion Information Press UP/DOWN arrows, select option 1 for inclusion. ### Exclusion Information Press UP/DOWN arrows, select option 0 for exclusion. ## Channels The following table summarises the channels available for the TH8320ZW -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature | | Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number | | Operating State | thermostat_state | thermostat_state | Temperature | Number | | Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | | | | Thermostat fan state | thermostat_fanstate | thermostat_fanstate | | | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat mode Sets the thermostat. The ```thermostat_mode``` channel is of type ```thermostat_mode``` and supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Operating State Sets the thermostat operating state. The ```thermostat_state``` channel is of type ```thermostat_state``` and supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Idle | | 1 | Heating | | 2 | Cooling | | 3 | Fan Only | | 4 | Pending Heat | | 5 | Pending Cool | | 6 | Vent / Economiser | ### Setpoint (heating) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (cooling) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Thermostat fan mode Channel type information on this channel is not found. ### Thermostat fan state Channel type information on this channel is not found. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The TH8320ZW supports 1 association group. ### Group 1: Relationship of devices in the network Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V3| | | COMMAND_CLASS_THERMOSTAT_MODE_V2| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Operating Manual](https://opensmarthouse.org/zwavedatabase/182/reference/69-2485EFS.pdf) * [Installation Manual](https://opensmarthouse.org/zwavedatabase/182/reference/69-2486.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/182).