--- layout: documentation title: HS-FS100-L - ZWave --- {% include base.html %} # HS-FS100-L Homeseer Z-Wave Indicator Light Sensor This describes the Z-Wave device *HS-FS100-L*, manufactured by *[HomeSeer Technologies](http://www.homeseer.com/)* with the thing type UID of ```homeseer_hsfs100l_00_000```. This version of the device is limited to firmware versions below 5.17 The device is in the category of *Sensor*, defining Device used to measure something. ![HS-FS100-L product image](https://opensmarthouse.org/zwavedatabase/1026/image/) The HS-FS100-L supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview HS-FS100-L is a sensor designed to monitor indicator lights on appliances and other equipment in your home. It will send Z-Wave commands to your smart home system when things turn on, turn off or change their status. **Main Features** * Indicator Light Sensor * Temperature Sensor * Z-Wave Controllable Buzzer * Acts as a Z-Wave repeater when used on line power ### Inclusion Information 1. Attach the included light or water sensor cable. Put your home automation controller into Z-Wave ‘inclusion’ mode. 2. Press the Z-Wave network button on the front of the unit one time. Wait for the inclusion process to finish. This may take some time. ### Exclusion Information 1. Put your home automation controller into Z-Wave ‘exclusion’ mode. 2. Press the Z-Wave network button on the front of the unit one time. Wait for the exclusion process to finish. This may take some time. ## Channels The following table summarises the channels available for the HS-FS100-L -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Binary Sensor | sensor_binary | sensor_binary | | Switch | | Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature | | Alarm | alarm_general | alarm_general | Alarm | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Binary Sensor Indicates if a sensor has triggered. The ```sensor_binary``` channel is of type ```sensor_binary``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Triggered | | OFF | Untriggered | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 4 configuration parameters available in the HS-FS100-L. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Light Sensitvity | Light Sensitvity | | 2 | Water Detecton beep frequency | Water Detecton beep frequency | | 3 | Temperature reportng interval when on line power | Temperature reportng interval when on line power | | 4 | Enable Notfcaton Buzzer | Enable Notfcaton Buzzer | ### Parameter 1: Light Sensitvity Light Sensitvity 0=high sensitvity 1=medium sensitvity 2=low sensitvity Values in the range 0 to 2 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Water Detecton beep frequency Water Detecton beep frequency 0=every 10 minutes (approx batery life of 3 months in this mode) 1=every 5 minutes 2=every 30 minutes Values in the range 0 to 2 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Temperature reportng interval when on line power Temperature reportng interval when on line power 30-255 seconds, default=60 Values in the range 30 to 255 may be set. The manufacturer defined default value is ```60```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Enable Notfcaton Buzzer Enable Notfcaton Buzzer 0 = Disabled 1 = Enabled (Default) Values in the range 0 to 1 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The HS-FS100-L supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Flex Sensor supports Group 1 association. Group 1 reports the sensor’s status and battery if running on batteries. Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SENSOR_BINARY_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V10| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V8| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [HS-FS100-L.pdf](https://opensmarthouse.org/zwavedatabase/1026/reference/HS-FS100-Manual-4.pdf) * [HS-FS100Plus Manual](https://opensmarthouse.org/zwavedatabase/1026/reference/HS-FS100Plus-Manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1026).