--- layout: documentation title: ZW3011/14322/46565 - ZWave --- {% include base.html %} # ZW3011/14322/46565 In-Wall Smart Toggle Dimmer This describes the Z-Wave device *ZW3011/14322/46565*, manufactured by *Jasco Products* with the thing type UID of ```ge_zw3011_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![ZW3011/14322/46565 product image](https://opensmarthouse.org/zwavedatabase/1219/image/) The ZW3011/14322/46565 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview In-Wall Smart Toggle Dimmer with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever! ### Inclusion Information Adding your device to a Z-Wave network: 1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. 2. Once the controller is ready to add your device, press up and release the toggle. ### Exclusion Information To remove and reset the device: 1. Follow the instructions for your Z-Wave certified controller to remove a device from the network. 2. Once the controller is ready to remove your device, press up and release the toggle. ### General Usage Information Button Press Functions * Cycle LED= Press 3 up then 1 down to cycle through LED status * Switch Mode = Press 5 up then 5 down if done successfully the LED will blink 5 times * Min Threshold = Press 4 down then 1 up, if done successfully the device will turn to 1% and the LED will start to blink signaling the device is in setup mode. Press and hold up or down to adjust the device to the desired minimum threshold. * Max Threshold = Press 4 up then 1 down, if done successfully the device will turn to 99% and the LED will start to blink signaling the device is in setup mode. Press and hold down or up to adjust the device to the desired maximum threshold.  ## Channels The following table summarises the channels available for the ZW3011/14322/46565 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | scene_number | | Number | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ## Device Configuration The following table provides a summary of the 7 configuration parameters available in the ZW3011/14322/46565. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | LED Mode | LED Indication Configuration | | 6 | Dim up/down rate | Adjust the speed at which the ramps to a specific value other than 0 and FF | | 16 | Switch Mode | Turn your dimmer into an On/Off switch with switch mode | | 19 | Alternate Exclusion | Never accidentally remove a device during with alternate exclusion | | 30 | Minimum Dim Threshold | Set the minimum dimmer threshold | | 31 | Maximum Brightness Threshold | Set the brightness threshold | | 32 | Default Brightness Level | Set the default brightness level for manual turn on | ### Parameter 3: LED Mode LED Indication Configuration Adjust the LED status to default, invert, always OFF or always ON The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Device is ON, LED is OFF; device is OFF, LED is ON | | 1 | Device is ON, LED is ON; device is OFF, LED is OFF | | 2 | LED always OFF | | 3 | LED always ON | The manufacturer defined default value is ```2``` (LED always OFF). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 6: Dim up/down rate Adjust the speed at which the ramps to a specific value other than 0 and FF 0 means "Dim up/down the light to the specified level quickly by command except value 0 and FF" 1 means "Dim up/down the light to the specified level slowly by command except value 0 and ff" The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Fast | | 1 | Slow | The manufacturer defined default value is ```0``` (Fast). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 16: Switch Mode Turn your dimmer into an On/Off switch with switch mode 0 for normal dimmer operation, 1 enables switch mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Dimmer Mode | | 1 | Switch Mode | The manufacturer defined default value is ```0``` (Dimmer Mode). This parameter has the configuration ID ```config_16_1``` and is of type ```INTEGER```. ### Parameter 19: Alternate Exclusion Never accidentally remove a device during with alternate exclusion 0: Normal operation, press any button on the device 1: Press two times ON button and two times OFF button, LED will flash 5 times if exclusion is successfulThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal exclusion | | 1 | Alternate Exclusion | The manufacturer defined default value is ```0``` (Normal exclusion). This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ### Parameter 30: Minimum Dim Threshold Set the minimum dimmer threshold Set the minimum dimmer threshold when manually or remotely controlled Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_30_1``` and is of type ```INTEGER```. ### Parameter 31: Maximum Brightness Threshold Set the brightness threshold Set the maximum brightness threshold when manually or remotely controlled Values in the range 0 to 99 may be set. The manufacturer defined default value is ```99```. This parameter has the configuration ID ```config_31_1``` and is of type ```INTEGER```. ### Parameter 32: Default Brightness Level Set the default brightness level for manual turn on Set the default brightness level that the dimmer will turn on when being controlled manually Ex. 1= 1% and 99 = 99% Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_32_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ZW3011/14322/46565 supports 3 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Association group 1 supports 5 nodes. ### Group 2: Single Press Supports Basic Set and is controlled by pressing the ON or OFF button with the local load Association group 2 supports 5 nodes. ### Group 3: Double Press Supports Basic Set and is controlled by double pressing the ON or OFF button Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_APPLICATION_STATUS_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1219/reference/14322-46565-Binder1.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1219).