--- layout: documentation title: DSI-101 binary switch - ZWave --- {% include base.html %} # DSI-101 binary switch DSI-101 binary switch This describes the Z-Wave device *DSI-101 binary switch*, manufactured by *[Defaro](http://defaro.ru)* with the thing type UID of ```defaro_dsi101_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![DSI-101 binary switch product image](https://opensmarthouse.org/zwavedatabase/835/image/) The DSI-101 binary switch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The DSI-101 binary switch does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview https://defaro.ru/index.php/support/instructions/208-dsi-101 ### Inclusion Information 1. Set controller in inclusion mode 2. Press button on the device for three seconds ### Exclusion Information 1. Set controller in exclusion mode 2. Press button on the device for three seconds ### Wakeup Information The DSI-101 binary switch does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. Press button on the device once. ## Channels The following table summarises the channels available for the DSI-101 binary switch -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Scene Number | scene_number | scene_number | | Number | | Central scene number | meter_current | meter_current | Energy | Number | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. ### Central scene number Never fired off due to the firmware bug, had to add SCENE_ACTIVATION manually Indicates the instantaneous current consumption. The ```meter_current``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The following table provides a summary of the 23 configuration parameters available in the DSI-101 binary switch. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | B1 operation mode | B1 operation mode | | 2 | B2 operation mode | B2 operation mode | | 3 | B3 operation mode | B3 operation mode | | 4 | B4 operation mode | B4 operation mode | | 5 | B5 operation mode | B5 operation mode | | 6 | B6 operation mode | B6 operation mode | | 7 | B7 operation mode | B7 operation mode | | 8 | B8 operation mode | B8 operation mode | | 9 | Long press delay | Delay for long press detection | | 10 | B1 value for AG 11 | B1 value to send for AG 11 | | 11 | B2 value to send | B2 value to send for AG 12 | | 12 | B3 value to send for AG 13 | B3 value to send for AG 13 | | 13 | B4 value to send | B4 value to send for AG 14 | | 14 | B5 value to send | B5 value to send for AG 15 | | 15 | B6 value to send | B6 value to send for AG 16 | | 16 | B7 value to send | B7 value to send for AG 17 | | 17 | B8 value to send | B8 value to send for AG 18 | | 20 | Sensor 1 turn on value | Sensor 1 turn on value for AG 19 | | 21 | Sensor 1 command off value | Sensor 1 command off value for AG19 | | 22 | Sensor 1 conversion rules | Sensor 1 conversion rules | | 23 | Sensor 2 command on value | Sensor 2 command on value for AG 20 | | 24 | Sensor 2 command off value | Sensor 2 command off value for AG 20 | | 25 | Sensor 2 conversion rules | Sensor 2 conversion rules | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | ### Parameter 1: B1 operation mode B1 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 3 or 11 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 3 or 11 (only first device from this AG is supported!) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: B2 operation mode B2 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 4 or 12 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 4 or 12 (only first device from this AG is supported) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: B3 operation mode B3 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 5 or 13 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 5 or 13 (only first device from this AG is supported) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: B4 operation mode B4 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 4 or 12 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 4 or 12 (only first device from this AG is supported) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: B5 operation mode B5 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 7 or 15 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 7 or 15 (only first device from this AG is supported) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: B6 operation mode B6 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 8 or 16 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 8 or 16 (only first device from this AG is supported) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: B7 operation mode B7 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 9 or 17 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 9 or 17 (only first device from this AG is supported) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: B8 operation mode B8 operation mode 0 - Turn off for short press/Dim down for hold (monostable switch) 1 - Turn on for short press/Dim up for hold (monostable switch) 2 - Bistable switch 3 - Scene activation mode 4 - Monostable switch. Each press/hold switches on/off/sends dim up/down state for devices from AG 10 or 18 (only first device from this AG is supported!) 5 - Bistable switch for devices from AG 10 or 18 (only first device from this AG is supported) Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Long press delay Delay for long press detection In 1/10 of sec Values in the range 1 to 50 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: B1 value for AG 11 B1 value to send for AG 11 Value to send to AG 11  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: B2 value to send B2 value to send for AG 12 Value to send to AG 12  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: B3 value to send for AG 13 B3 value to send for AG 13 Value to send to AG 13  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: B4 value to send B4 value to send for AG 14 Value to send to AG 14  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: B5 value to send B5 value to send for AG 15 Value to send to AG 15  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: B6 value to send B6 value to send for AG 16 Value to send to AG 16  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 16: B7 value to send B7 value to send for AG 17 Value to send to AG 17  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_16_1``` and is of type ```INTEGER```. ### Parameter 17: B8 value to send B8 value to send for AG 18 Value to send to AG 18  (0 - disable this functionality) Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_17_1``` and is of type ```INTEGER```. ### Parameter 20: Sensor 1 turn on value Sensor 1 turn on value for AG 19 Values in the range -60 to 1000 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_20_2``` and is of type ```INTEGER```. ### Parameter 21: Sensor 1 command off value Sensor 1 command off value for AG19 Values in the range -60 to 1000 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_21_2``` and is of type ```INTEGER```. ### Parameter 22: Sensor 1 conversion rules Sensor 1 conversion rules All commands are sent to devices in AG 19 0 - ignore sensor value 1 - send ON if Value <= Param20 and send OFF if Value >= Param21 2 - send OFF if Value <= Param21 and send ON if Value >= Param20 3 - send ON if Value <= Param20 4 - send ON if Value >= Param20 5 - send OFF if Value >= Param21 6 - send OFF if Value <= Param21 Values in the range 0 to 6 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_22_1``` and is of type ```INTEGER```. ### Parameter 23: Sensor 2 command on value Sensor 2 command on value for AG 20 Values in the range -60 to 1000 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_23_2``` and is of type ```INTEGER```. ### Parameter 24: Sensor 2 command off value Sensor 2 command off value for AG 20 Values in the range -60 to 1000 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_24_2``` and is of type ```INTEGER```. ### Parameter 25: Sensor 2 conversion rules Sensor 2 conversion rules All commands are sent to devices in AG 20 0 - ignore sensor value 1 - send ON if Value <= Param23 and send OFF if Value >= Param24 2 - send OFF if Value <= Param24 and send ON if Value >= Param23 3 - send ON if Value <= Param23 4 - send ON if Value >= Param23 5 - send OFF if Value >= Param24 6 - send OFF if Value <= Param24 Values in the range 0 to 6 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_25_1``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSI-101 binary switch supports 20 association groups. ### Group 1: Battery level Association group 1 supports 3 nodes. ### Group 2: Scene activation set Scene Ids:
Button B1 B2 B3 B4 B5 B6 B7 B8
SceneID 10 20 30 40 50 60 70 80
Association group 2 supports 3 nodes. ### Group 3: On/Off command for switch 1 Association group 3 supports 10 nodes. ### Group 4: On/Off command for switch 2 Association group 4 supports 10 nodes. ### Group 5: On/Off command for switch 3 Association group 5 supports 10 nodes. ### Group 6: On/Off command for switch 4 Association group 6 supports 10 nodes. ### Group 7: On/Off command for switch 5 Association group 7 supports 10 nodes. ### Group 8: On/Off command for switch 6 Association group 8 supports 10 nodes. ### Group 9: On/Off command for switch 7 Association group 9 supports 10 nodes. ### Group 10: On/Off command for switch 8 Association group 10 supports 10 nodes. ### Group 11: Dim command for switch 1 Association group 11 supports 10 nodes. ### Group 12: Dim command for switch 2 Association group 12 supports 10 nodes. ### Group 13: Dim command for switch 3 Association group 13 supports 10 nodes. ### Group 14: Dim command for switch 4 Association group 14 supports 10 nodes. ### Group 15: Dim command for switch 5 Association group 15 supports 10 nodes. ### Group 16: Dim command for switch 6 Association group 16 supports 10 nodes. ### Group 17: Dim command for switch 7 Association group 17 supports 10 nodes. ### Group 18: Dim command for switch 8 Association group 18 supports 10 nodes. ### Group 19: Sensor 1 group Association group 19 supports 5 nodes. ### Group 20: Sensor 2 group Association group 20 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2| | ### Documentation Links * [User Manual (Russian)](https://opensmarthouse.org/zwavedatabase/835/reference/dsi-101-manual-ru.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/835).