--- layout: documentation title: STZ1-345 - ZWave --- {% include base.html %} # STZ1-345 2GIG Z-Wave Plus Programmable Thermostat (2GIG-STZ1-345) This describes the Z-Wave device *STZ1-345*, manufactured by *2gig Technologies Inc.* with the thing type UID of ```2gig_stz1345_00_000```. The device is in the category of *HVAC*, defining Air condition devices, Fans. ![STZ1-345 product image](https://opensmarthouse.org/zwavedatabase/1426/image/) The STZ1-345 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The 2GIG-STZ-1 Thermostat is a programmable, Z-Wave communicating thermostat. It can be powered using 24VAC (if both “R”&”C”wires are available at the thermostat) or using four (4) AA batteries. Using Z-Wave technology, you have the ability to use most compatible Z-Wave hubs/controllers to operate the thermostat, configure programming settings as well as displaying current conditions in the home or office. ### Inclusion Information 1. Set your primary controller to Include, add or Install mode, to add the thermostat as a node on your network (see your controller’s user manual for detailed instructions). 2. Touch any button to take the thermostat out of sleep mode. 3. Touch and hold MODE button for 5 seconds. SETUP will be displayed in the status display line. 4. Scroll to “Z-Wave” using Up/Down buttons. Touch FAN (Select). 5. When prompted by your Z-Wave controller, select YES in the Z-Wave Install screen. 6. Touch FAN (Select) to add thermostat to network. 7. The display line should flash WAIT and then SUCCESS if Z-Wave connection is made. 8. If Z-Wave does not connect to controller, WAIT, then FAIL will flash in status display line. 9. If thermostat fails to connect, repeat Steps three (3) through (7) to re-try connecting. ### Exclusion Information 1. Set your primary controller to exclude or remove mode to remove the thermostat as a node on your network (see your controller’s user manual for detailed instructions). 2. Touch any button to take the thermostat out of sleep mode. 3. Touch and hold the MODE button for 5 seconds. SETUP will be displayed in the status display line. 4. Scroll to “Z-Wave” using Up/Down buttons. Touch FAN (Select). 5. When prompted by your Z-Wave controller, select YES in the Z-Wave exclude screen. 6. Touch FAN (Select) to remove thermostat to network. 7. The display line should flash WAIT then SUCCESS if the thermostat is removed from the network. 8. If the removal operation is not successful, WAIT will flash, then FAIL will flash in status display line. Repeat Steps three (3) through (7) to re-try ### General Usage Information ## Channels The following table summarises the channels available for the STZ1-345 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature | | Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number | | Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number | | Operating State | thermostat_state | thermostat_state | Temperature | Number | | Setpoint (auto changeover) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (moist air) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (furnace) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (dry air) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | | | | Thermostat fan state | thermostat_fanstate | thermostat_fanstate | | | | Battery Level | battery-level | system.battery_level | Battery | Number | | Clock Time Offset | time_offset | time_offset | Time | Number | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Sensor (relative humidity) Indicates the current relative humidity. The ```sensor_relhumidity``` channel is of type ```sensor_relhumidity``` and supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device. ### Thermostat mode Sets the thermostat. The ```thermostat_mode``` channel is of type ```thermostat_mode``` and supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Operating State Sets the thermostat operating state. The ```thermostat_state``` channel is of type ```thermostat_state``` and supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Idle | | 1 | Heating | | 2 | Cooling | | 3 | Fan Only | | 4 | Pending Heat | | 5 | Pending Cool | | 6 | Vent / Economiser | ### Setpoint (auto changeover) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (moist air) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (cooling) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (heating) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (furnace) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (dry air) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Thermostat fan mode Channel type information on this channel is not found. ### Thermostat fan state Channel type information on this channel is not found. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ### Clock Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel is of type ```time_offset``` and supports the ```Number``` item and is in the ```Time``` category. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The STZ1-345 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 2 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V6| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_SCHEDULE_V1| | | COMMAND_CLASS_TRANSPORT_SERVICE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_SUPERVISION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_INDICATOR_V3| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_SECURITY_V1| | | COMMAND_CLASS_SECURITY_2_V1| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/1426/reference/10028238_Rev-E_-_2GIG-STZ-1_User_Guide_PRINT.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1426).