--- layout: documentation title: YRD216 - ZWave --- {% include base.html %} # YRD216 Yale Real Living Assure Lock Push Button Deadbolt This describes the Z-Wave device *YRD216*, manufactured by *ASSA ABLOY* with the thing type UID of ```yale_yrd216_00_000```. The device is in the category of *Lock*, defining Devices whose primary pupose is locking something. ![YRD216 product image](https://opensmarthouse.org/zwavedatabase/1037/image/) The YRD216 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. ## Overview Yale Assure Lock * Push Button keypad with backlit numbers that won’t wear off * Mechanical key override * Manage up to 25 unique codes to share with friends and family * Weather Protection Gasket * One-touch locking and keypad wake-up * Privacy Mode – privacy button located on the interior side of the lock enables users to temporarily disable user codes * Tamper Resistant Battery Cover * Tamper Alert – audible alarm sounds if there is an attempt to forcibly remove the lock * Automatically relocks after 30 seconds * Simple to install on standard doors and replaces your existing deadbolt in minutes with just a screwdriver * Certified ANSI/BHMA A156.36, Grade 2 * Lifetime limited warranty for finish and mechanical, one year electronics ### Inclusion Information To join the lock in a Z-Wave Network (taken from the installation manual) 1. Enter the master pin and press # 2. Press 7, then # 3. Press 1, then # The lock will now be in inclusion mode. ### Exclusion Information To exit the Z-Wave Network (taken from the installation manual) 1. Enter the master pin and press # 2. Press 7, then # 3. Press 3, then # The lock will now be in exclusion mode. ## Channels The following table summarises the channels available for the YRD216 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Door Lock | lock_door | lock_door | Door | Switch | | Alarm | alarm_general | alarm_general | Alarm | Switch | | Alarm (raw) | alarm_raw | alarm_raw | | String | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Door Lock Lock and unlock the door. The ```lock_door``` channel is of type ```lock_door``` and supports the ```Switch``` item and is in the ```Door``` category. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Locked | | OFF | Unlocked | ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Alarm (raw) Provides alarm parameters as json string. The ```alarm_raw``` channel is of type ```alarm_raw``` and supports the ```String``` item. This is a read only channel so will only be updated following state changes from the device. This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The following table provides a summary of the 11 configuration parameters available in the YRD216. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Silent mode | Silent mode on/off | | 2 | Auto Relock | Auto Relock on/off | | 3 | Auto Relock Time | Auto Relock Time | | 4 | Wrong code Entry Limit | Wrong code Entry Limit | | 5 | Language | Language | | 7 | Shut down time | Shut down time after wrong code entries | | 8 | Operating mode | Operating mode | | 11 | One touch locking | One touch locking | | 12 | Privacy button | Privacy button | | 13 | Lock status LED | Lock status LED | | 15 | Reset to factory default | Reset to factory default | | | Lock Timeout | Sets the time after which the door will auto lock | ### Parameter 1: Silent mode Silent mode on/off Default is 1 or High Volume The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Loud | | 2 | Quiet | | 3 | Off | The manufacturer defined default value is ```1``` (Loud). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Auto Relock Auto Relock on/off default is 0x00 or OFF The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Auto relock off | | 255 | Auto relock on | The manufacturer defined default value is ```0``` (Auto relock off). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Auto Relock Time Auto Relock Time 10 to 180 seconds (default is 30 seconds) Values in the range 10 to 180 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Wrong code Entry Limit Wrong code Entry Limit 3 to 10 (default is 5 times) Values in the range 3 to 10 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Language Language 1=English, 2=Spanish, 3=French (default is 1= English) The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | English | | 2 | Spanish | | 3 | French | The manufacturer defined default value is ```1``` (English). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: Shut down time Shut down time after wrong code entries 10 to 180 seconds (default is 60 seconds) Values in the range 10 to 180 may be set. The manufacturer defined default value is ```60```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Operating mode Operating mode 00 = normal mode (this is the default mode) 01 = vacation mode, keypad lockout 02 = privacy mode, no keypad. RF Unlock will work The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal | | 1 | Vacation | | 2 | Privacy | The manufacturer defined default value is ```0``` (Normal). This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 11: One touch locking One touch locking 0x00 = OFF, 0xFF = ON (default) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Privacy button Privacy button 0x00 = OFF (default), 0xFF = ON Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Lock status LED Lock status LED 0x00 = OFF (default), 0xFF = ON Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 15: Reset to factory default Reset to factory default 01 = Lock will execute Reset To Factory. Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Lock Timeout Sets the time after which the door will auto lock. This parameter has the configuration ID ```doorlock_timeout``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The YRD216 supports 1 association group. ### Group 1: Association group Lifeline Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_DOOR_LOCK_LOGGING_V1| | | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2| | | COMMAND_CLASS_DOOR_LOCK_V2| | | COMMAND_CLASS_USER_CODE_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| Linked to BASIC| | COMMAND_CLASS_TIME_V2| | | COMMAND_CLASS_TIME_PARAMETERS_V1| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [YRD216 manual](https://opensmarthouse.org/zwavedatabase/1037/reference/YRD216.pdf) * [YRD216 Deadbolt lock](https://opensmarthouse.org/zwavedatabase/1037/reference/YRD216.pdf) * [Yale Z-Wave plus system integrators guide](https://opensmarthouse.org/zwavedatabase/1037/reference/Yale-Real-Living-ZWave-Plus-System-Integrators-Guide-YRL-deadbolts-Rev-4.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1037).