--- layout: documentation title: EN00 - ZWave --- {% include base.html %} # EN00 Engie Meter Adapter This describes the Z-Wave device *EN00*, manufactured by *Quby* with the thing type UID of ```quby_en00_00_000```. The device is in the category of *Sensor*, defining Device used to measure something. ![EN00 product image](https://opensmarthouse.org/zwavedatabase/1070/image/) The EN00 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The meter adapter measures gas and electricity usage of analog meters. The analog meters are read by means of optical sensors that can be placed on the meter to monitor the rotating disc or the blinking LED. The meter adapter measures the cumulative and instantaneous gas and electricity consumption. ### Inclusion Information To add the Meter Module into a Z-Wave network, the inclusion process should be started on the controller. In factory default mode, the Meter Module will try to join a Z-Wave network automatically after being plugged into a power socket. If the Meter Module was previously included in a Z-Wave network, or was not just plugged into a power socket, one needs to triple-press the button (quickly). ### Exclusion Information The button on the Meter Module should be triple-pressed (quickly). ## Channels The following table summarises the channels available for the EN00 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Gas meter (cubic meters) | meter_gas_cubic_meters | meter_gas_cubic_meters | Energy | Number | | Clock Time Offset | time_offset | time_offset | Time | Number | ### Gas meter (cubic meters) Indicates the gas use in cubic meters. The ```meter_gas_cubic_meters``` channel is of type ```meter_gas_cubic_meters``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Clock Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel is of type ```time_offset``` and supports the ```Number``` item and is in the ```Time``` category. ## Device Configuration The following table provides a summary of the 6 configuration parameters available in the EN00. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Analog gas/heat port mode | Analog gas/heat port mode | | 2 | Analog gas/heat port resolution | Analog gas/heat port resolution | | 3 | Analog electricity port mode | Analog electricity port mode | | 4 | Analog electricity port resolution | Analog electricity port resolution | | 5 | Digital port mode | Digital port mode | | 255 | Restart device | Restart device | ### Parameter 1: Analog gas/heat port mode Analog gas/heat port mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Gas Enabled | | 2 | Heat Enabled | The manufacturer defined default value is ```1``` (Gas Enabled). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Analog gas/heat port resolution Analog gas/heat port resolution Analog gas/heat port resolution (pulses per cubic meter / pulses per MJ; in Q14.2 notation) Values in the range 120 to 40000 may be set. The manufacturer defined default value is ```400```. This parameter has the configuration ID ```config_2_4``` and is of type ```INTEGER```. ### Parameter 3: Analog electricity port mode Analog electricity port mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Electricity import enabled | | 2 | Electricity export enabled | The manufacturer defined default value is ```1``` (Electricity import enabled). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Analog electricity port resolution Analog electricity port resolution Analog electricity port resolution (pulses per kWh; in Q14.2 notation) Values in the range 120 to 40000 may be set. The manufacturer defined default value is ```400```. This parameter has the configuration ID ```config_4_4``` and is of type ```INTEGER```. ### Parameter 5: Digital port mode Digital port mode Values in the range 0 to 2 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 255: Restart device Restart device The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Restart entire device | | 2 | Restart metering chip | The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_255_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The EN00 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_APPLICATION_STATUS_V1| | | COMMAND_CLASS_METER_V2| | | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_CRC_16_ENCAP_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_TIME_PARAMETERS_V1| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 3 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 4 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 5 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 6 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 7 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 8 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 9 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_METER_TBL_CONFIG_V1| | | COMMAND_CLASS_METER_TBL_MONITOR_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1070/reference/MM-documentation.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1070).