--- layout: documentation title: GE/Jasco 14285 - ZWave --- {% include base.html %} # GE/Jasco 14285 Direct Wire Indoor/Outdoor Smart Switch This describes the Z-Wave device *GE/Jasco 14285*, manufactured by *Jasco Products* with the thing type UID of ```ge_14285_00_000```. The device is in the category of *Remote Control*, defining Any portable or hand-held device that controls the status of something, e.g. remote control, keyfob etc.. ![GE/Jasco 14285 product image](https://opensmarthouse.org/zwavedatabase/897/image/) The GE/Jasco 14285 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview **SPECIFICATIONS ZW4007** * Power: 120-277 VAC, 60Hz, Single Phase * Range: Up to 150 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module. * Operating Temperature Range: -22 to 104° F (-30 to 40° C) * For outdoor use in dry, damp or wet locations. * Contact Ratings: 120-277 VAC, 40A Resistive Single Phase 120-277 VAC, 20A Ballast load (Inductive) Single phase 125 VAC, 15 A Tungsten 250 VAC, 5 A Tungsten 1HP@120VAC, 2HP @ 240VAC **Features** * Operation mode switch allows operation without requiring Z-Wave network * Remote ON/OFF control via the Z-Wave controller, on mobile devices * Manual override ON/OFF control with the exterior-mounted pushbutton * Weather-resistant, rainproof housing; suitable for use outdoors in damp or wet conditions * Lockable tamper-resistant metal case ensures secure connection and keeps dirt & debris out * Energy monitoring capability allows remote monitoring of watts and kilowatt hours with compatible systems  Device Reset To return your device to factory defaults 1. Place device into ON mode (upper position of Operating Mode Switch) 2. Press and hold the programming button. 3. While holding programming button, place device into OFF mode (middle position of Operating Mode Switch). 4. While holding programming button, place device back into ON mode (upper position of Operating Mode Switch). 5. After three (3) seconds, release programming button. Green LED will flash 5 times when completed successfully. ### Inclusion Information Once the controller is ready to add your device, press and release the programming button to add it to the network.  ### Exclusion Information Once the controller is ready to remove your device press and release the programming button to remove it from the network. ## Channels The following table summarises the channels available for the GE/Jasco 14285 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | | Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | | Electric meter (amps) | meter_current | meter_current | Energy | Number | | Scene Number | scene_number | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (power factor) Indicates the instantaneous power factor. The ```meter_powerfactor``` channel is of type ```meter_powerfactor``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ## Device Configuration The following table provides a summary of the 4 configuration parameters available in the GE/Jasco 14285. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Product State after Power Reset | Product State after Power Reset | | 2 | Energy Report Mode | Energy Report Mode | | 3 | Energy Report Frequency | Energy Report Frequency | | 19 | Alternate Exclusion | Alternate Exclusion | ### Parameter 1: Product State after Power Reset Product State after Power Reset The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Return to last state | | 1 | Return to off | | 2 | Return to on | The manufacturer defined default value is ```0``` (Return to last state). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Energy Report Mode Energy Report Mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Once monthly | | 1 | Reports based on Parameter 3 setting | | 2 | Once daily | The manufacturer defined default value is ```0``` (Once monthly). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Energy Report Frequency Energy Report Frequency Values in the range 5 to 60 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 19: Alternate Exclusion Alternate Exclusion This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Default | | 1 | Alternate Exclusion (3 button presses) | The manufacturer defined default value is ```0``` (Default). This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The GE/Jasco 14285 supports 3 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ### Group 2: Basic Set, controlled by local load Association group 2 supports 5 nodes. ### Group 3: Basic Set, controlled by pressing the On or Off button Basic Set, controlled by pressing the On or Off button Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [14285 Manual](https://opensmarthouse.org/zwavedatabase/897/reference/14285-QSG-V1.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/897).