--- layout: documentation title: 50x5xx - ZWave --- {% include base.html %} # 50x5xx Roller shutter push-button This describes the Z-Wave device *50x5xx*, manufactured by *Merten* with the thing type UID of ```merten_50x5xx_00_000```. This version of the device is limited to firmware versions below 1.5 The device is in the category of *Blinds*, defining Roller shutters, window blinds, etc.. ![50x5xx product image](https://opensmarthouse.org/zwavedatabase/1416/image/) The 50x5xx supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The roller shutter push-button contains a radio receiver for the Merten CONNECT radio system. If you use the blind control inserts 580699 or 580698, you can operate the connected roller shutter drive remotely using a Merten CONNECT radio transmitter. You can also operate the roller shutters using the rocker on the roller shutter push-button. You can use the Merten CONNECT radio button, the Merten CONNECT radio remote control or the Merten CONNECT radio central unit as the transmitter. ### Inclusion Information Program (transmits Node info frame) Triple click on operating surface. Used for include/exclude the device by the primary ### Exclusion Information Reset to the factory settings; exclude Triple click on operating surface. Used for include/exclude the device by the primary ### General Usage Information ## Channels The following table summarises the channels available for the 50x5xx -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | | switch_binary | switch_binary | Switch | Switch | | Blinds control | blinds_control | blinds_control | Blinds | Rollershutter | ### Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Blinds control Provides start / stop control of blinds. The ```blinds_control``` channel is of type ```blinds_control``` and supports the ```Rollershutter``` item and is in the ```Blinds``` category. ## Device Configuration The following table provides a summary of the 11 configuration parameters available in the 50x5xx. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 176 | Changeover delay (motor protection) | Changeover delay (motor protection) | | 177 | Raising time (Input 1) | Raising time (Input 1) | | 178 | Raising time (Input 2) | Raising time (Input 1) | | 179 | Lowering time (input 1) | Lowering time (input 1) | | 180 | Lowering time (input 2) | Lowering time (input 2) | | 181 | Inclusion of light sensor | Inclusion of light sensor | | 182 | Brightness threshold | Brightness threshold | | 183 | Reaction threshold for raising shutter (Input 1) | Reaction threshold for raising shutter (Input 1) | | 184 | Reaction threshold for raising shutter (Input 2) | Reaction threshold for raising shutter (Input 2) | | 185 | Reaction threshold for lowering shutter (Input 1) | Reaction threshold for lowering shutter (Input 1) | | 186 | Reaction threshold for lowering shutter (Input 1) | Reaction threshold for lowering shutter (Input 1) | ### Parameter 176: Changeover delay (motor protection) Changeover delay (motor protection) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_176_1``` and is of type ```INTEGER```. ### Parameter 177: Raising time (Input 1) Raising time (Input 1) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_177_1``` and is of type ```INTEGER```. ### Parameter 178: Raising time (Input 2) Raising time (Input 1) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_178_1``` and is of type ```INTEGER```. ### Parameter 179: Lowering time (input 1) Lowering time (input 1) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_179_1``` and is of type ```INTEGER```. ### Parameter 180: Lowering time (input 2) Lowering time (input 2) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_180_1``` and is of type ```INTEGER```. ### Parameter 181: Inclusion of light sensor Inclusion of light sensor The following option values may be configured, in addition to values in the range 0 to 255 -: | Value | Description | |--------|-------------| | 0 | Auto | | 1 | Enable | | 2 | Disable | The manufacturer defined default value is ```0``` (Auto). This parameter has the configuration ID ```config_181_1``` and is of type ```INTEGER```. ### Parameter 182: Brightness threshold Brightness threshold Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_182_1``` and is of type ```INTEGER```. ### Parameter 183: Reaction threshold for raising shutter (Input 1) Reaction threshold for raising shutter (Input 1) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_183_1``` and is of type ```INTEGER```. ### Parameter 184: Reaction threshold for raising shutter (Input 2) Reaction threshold for raising shutter (Input 2) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_184_1``` and is of type ```INTEGER```. ### Parameter 185: Reaction threshold for lowering shutter (Input 1) Reaction threshold for lowering shutter (Input 1) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_185_1``` and is of type ```INTEGER```. ### Parameter 186: Reaction threshold for lowering shutter (Input 1) Reaction threshold for lowering shutter (Input 1) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_186_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 50x5xx supports 1 association group. ### Group 1: Other device to be switched Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_BASIC_WINDOW_COVERING_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1416/reference/merten-roller-shutter-web.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1416).