--- layout: documentation title: MH-S513 - ZWave --- {% include base.html %} # MH-S513 Touch Panel Switch 3-Way This describes the Z-Wave device *MH-S513*, manufactured by *[McoHome Technology Co., Ltd](http://www.mcohome.com/)* with the thing type UID of ```mcohome_mhs513_00_000```. This version of the device is limited to firmware versions below 4.255 The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![MH-S513 product image](https://opensmarthouse.org/zwavedatabase/952/image/) The MH-S513 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Touch Panel Switch is a wall panel built-in with Z-Wave Plus module. With its stylish design and stable performance, the panel can be used to control house-hold electrical appliances like lamp, motor, coffee machine, TV set etc. It supports basic command class,multi channel command class and multi channel association command class, also works as a repeater in a Z-Wave network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. ### Inclusion Information INCLUDING the device into Z-Wave network: 1. Set controller into INCLUSION mode. Follow instructions provided by controller manufacturer. 2. Press and hold any key on the panel for 8 seconds or 3 clicks in quick succession. Note: If inclusion is successful, all INDICATION LEDs on the panel will flash 4 times.  ### Exclusion Information EXCLUDING the device from Z-Wave network: 1. Set controller into EXCLUSION mode. Follow instructions provided by controller manufacturer. 2. Press and hold any key on the panel for 8 seconds or 3 clicks in quick succession. Note: If the exclusion is successful, all INDICATION LEDs on the panel will flash 4 times. The exclusion will delete all association data. ### General Usage Information ## Channels The following table summarises the channels available for the MH-S513 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | scene_number | | Number | | Switch 1 | switch_binary1 | switch_binary | Switch | Switch | | Switch 2 | switch_binary2 | switch_binary | Switch | Switch | | Switch 3 | switch_binary3 | switch_binary | Switch | Switch | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 3 Switch the power on and off. The ```switch_binary3``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 5 configuration parameters available in the MH-S513. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Switch state saved or not when power failure | Switch state saved or not when power failure | | 3 | ALL ON/ALL OFF | ALL ON/ALL OFF | | 4 | LED Backlit brightness level | LED Backlit brightness level | | 5 | Key Mode | Key Mode | | 6 | Key On duration | Key On duration | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 2: Switch state saved or not when power failure Switch state saved or not when power failure 0=not saved,switch will be off when powered again 1=saved,switch will keep the same state when powered again Values in the range 0 to 1 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: ALL ON/ALL OFF ALL ON/ALL OFF

0=forbid ALL ON, forbid ALL OFF

1=forbid ALL ON, allow ALL OFF

2=allow ALL ON, forbid ALL OFF

255=allow ALL ON, allow ALL OFF

Values in the range 0 to 255 may be set. The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: LED Backlit brightness level LED Backlit brightness level 0 LED disabled 1-10 Min level-Max level >10 same level as 10 Values in the range 0 to 10 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Key Mode Key Mode 0=single click to switch on/off status 1=Key default as off state. When it is turned on, then it will be turned off automatically after a time period , which can be set in item 5 2=Key default as on state. When it is turned off, then it will be turned on automatically after a time period , which can be set in item 5 3=hold >3s then key is on, and off once released 4=single click to switch on/off status +hold >3s then key is on, and off once released Values in the range 0 to 4 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Key On duration Key On duration 0x00 infinite 1~65535 unit "sec" Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_6_2``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The MH-S513 supports 4 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Associate with gateway Send unsolicited reports to the gateway Association group 1 supports 1 node. ### Group 2: Associate with Key 1 Associate with Key 1 send Basic Set Command to associated devices Association group 2 supports 5 nodes. ### Group 5: Associate with Key 2 if any Associate with Key 2 if any send Basic Set Command to associated devices Association group 5 supports 5 nodes. ### Group 8: Associate with Key 3 if any Associate with Key 3 if any send Basic Set Command to associated devices Association group 8 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V2| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 3 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | ### Documentation Links * [Device Manual](https://opensmarthouse.org/zwavedatabase/952/reference/20180227145212.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/952).