--- layout: documentation title: JWZH-O-2015-14 - ZWave --- {% include base.html %} # JWZH-O-2015-14 Gas Water Valve Controller This describes the Z-Wave device *JWZH-O-2015-14*, manufactured by *Shenzhen iSurpass Technology Co. ,Ltd* with the thing type UID of ```isurpass_jwzho201514_00_000```. The device is in the category of *Valve*, defining Valves used to control water or gas. e.g. a flow stop valve.. ![JWZH-O-2015-14 product image](https://opensmarthouse.org/zwavedatabase/1207/image/) The JWZH-O-2015-14 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Valve controller with on/off operation. Can be mounted on various valve handles (water, gas or other) for remote control.  Specifications: * Power Voltage : DC12V/1A * Communication Technology : Z-WAVE PLUS  EU868.42MHz * Wireless Distance(Outdoor) : 30 Meters * Valve Pressure : 1.6MPa * Time Off Valve Auto : 5~10 sencod * Time Off Valve Electric : 5~10 sencod * Torque : 30~60 Kg.cm ### Inclusion Information With controller in inclusion mode, triple click the button within 1 second on the valve. ### Exclusion Information With controller in exclusion mode, triple click the button within 1 second on the valve. ## Channels The following table summarises the channels available for the JWZH-O-2015-14 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The JWZH-O-2015-14 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Short Manual](https://opensmarthouse.org/zwavedatabase/1207/reference/JWZH-O-2015-14.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1207).