--- layout: documentation title: Plug-In Smart Meter Dimmer Switch - ZWave --- {% include base.html %} # Plug-In Smart Meter Dimmer Switch ZWN323M This describes the Z-Wave device *Plug-In Smart Meter Dimmer Switch*, manufactured by *Wenzhou MTLC Electric Appliances Co.,Ltd.* with the thing type UID of ```enerwave_zwn323m_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![Plug-In Smart Meter Dimmer Switch product image](https://opensmarthouse.org/zwavedatabase/756/image/) The Plug-In Smart Meter Dimmer Switch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview This ZWN-323 Dimming Module is a Z-Wave enabled device and is fully interoperable with other Z-Wave certified device. In a Z-Wave network, ZWN-323M enable you to remotely ON/OFF&Dim control a Z-Wave ZWN-323M also acts as a repeater, retransmitting the RF signal from one device to another until the intended device is reached. With a horizontal design, the ZWN-323M plug-in dimmer module will not block other nearby AC outlets. ### Inclusion Information  While the gateway/remote is in the adding mode and the blue LED blinks on the ZWN-323M, press the program button on the module.  ### Exclusion Information While the gateway or remote in the deleting mode, press the program button on the ZWN-323M. The gateway or remote will verify the deleting, remove the module from the current Z-Wave network, and the LED will blink on the module.  ## Channels The following table summarises the channels available for the Plug-In Smart Meter Dimmer Switch -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Sensor (power) | sensor_power | sensor_power | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Sensor (power) Indicates the energy consumption (kWh). The ```sensor_power``` channel is of type ```sensor_power``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 6 configuration parameters available in the Plug-In Smart Meter Dimmer Switch. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Synchronization of load power and LED indicator | Synchronization of load power and LED indicator | | 8 | Autosend Interval (METER_REPORT) | Autosend Interval (METER_REPORT) | | 9 | Autosend interval (SENSOR_MULTILEVEL_REPORT) | Autosend interval (SENSOR\_MULTILEVEL\_REPORT) | | 10 | Accumulated Autosend Interval ( METER_REPORT) | Accumulated Autosend Interval ( METER_REPORT) | | 11 | Enable automatic notifications | Enable automatic notifications | | 12 | Minimum change in wattage report | Minimum change in wattage report | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Synchronization of load power and LED indicator Synchronization of load power and LED indicator The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Power on, LED off | | 1 | Power on, LED on | The manufacturer defined default value is ```0``` (Power on, LED off). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 8: Autosend Interval (METER_REPORT) Autosend Interval (METER_REPORT) Instant Energy Autosend Interval (send METER_REPORT) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Autosend interval (SENSOR_MULTILEVEL_REPORT) Autosend interval (SENSOR\_MULTILEVEL\_REPORT) Instant Energy Autosend interval (send SENSOR\_MULTILEVEL\_REPORT) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Accumulated Autosend Interval ( METER_REPORT) Accumulated Autosend Interval ( METER_REPORT) Accumulated Energy Autosend Interval report (send METER_REPORT) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Enable automatic notifications Enable automatic notifications Device will send a notification whenever the is a wattage change The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Not report (METER_REPORT) | | 1 | Send (METER_REPORT) only | | 2 | Send (SENSOR\_MULTI\_LEVEL_REPORT) only | | 3 | Send both | The manufacturer defined default value is ```1``` (Send (METER_REPORT) only). This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Minimum change in wattage report Minimum change in wattage report 0-255: 0.0-25.5W Values in the range 0 to 255 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The Plug-In Smart Meter Dimmer Switch supports 3 association groups. ### Group 1: Notifications Lifeline Association group 1 supports 1 node. ### Group 2: StatusReport Send basic report Association group 2 supports 5 nodes. ### Group 3: PowerReport PowerReport: Send meter power report Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| | | COMMAND_CLASS_METER_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Installation Instructions](https://opensmarthouse.org/zwavedatabase/756/reference/ZWN-323M-0430.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/756).