--- layout: documentation title: ADC-T 2000 - ZWave --- {% include base.html %} # ADC-T 2000 Alarm.com Smart Thermostat This describes the Z-Wave device *ADC-T 2000*, manufactured by *Building 36 Technologies* with the thing type UID of ```building36_adct2000_00_000```. The device is in the category of *HVAC*, defining Air condition devices, Fans. ![ADC-T 2000 product image](https://opensmarthouse.org/zwavedatabase/926/image/) The ADC-T 2000 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview * Intelligently Connected with Alarm.com (Alarm.com account required) * Remote Access and Control * Custom Schedules * Critical Temperature Alerts and Geo-Services Automation * Can be paired with Alarm.com Temperature Sensor ADC-S2000-T-RA for enhanced climate control and improved energy savings (sold separately) ### Inclusion Information Put thermostat in OFF mode (no mode icons are lit) Press and hold the DOWN button to begin inclusion mode. Release when the RADIO icon lights up. When the RADIO icon becomes solid, the thermostat has been included. ### Exclusion Information Put thermostat in OFF mode (no mode icons are lit) Press and hold the DOWN button to begin exclusion mode. Release when the RADIO icon lights up. When the RADIO icon flashes red, the thermostat has been excluded. ### Wakeup Information The ADC-T 2000 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. ## Channels The following table summarises the channels available for the ADC-T 2000 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature | | Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number | | Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number | | Operating State | thermostat_state | thermostat_state | Temperature | Number | | Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | | | | Thermostat fan state | thermostat_fanstate | thermostat_fanstate | | | | Battery Level | battery-level | system.battery_level | Battery | Number | | Clock Time Offset | time_offset | time_offset | Time | Number | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Sensor (relative humidity) Indicates the current relative humidity. The ```sensor_relhumidity``` channel is of type ```sensor_relhumidity``` and supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device. ### Thermostat mode Sets the thermostat. The ```thermostat_mode``` channel is of type ```thermostat_mode``` and supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Operating State Sets the thermostat operating state. The ```thermostat_state``` channel is of type ```thermostat_state``` and supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Idle | | 1 | Heating | | 2 | Cooling | | 3 | Fan Only | | 4 | Pending Heat | | 5 | Pending Cool | | 6 | Vent / Economiser | ### Setpoint (heating) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (cooling) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Thermostat fan mode Channel type information on this channel is not found. ### Thermostat fan state Channel type information on this channel is not found. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ### Clock Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel is of type ```time_offset``` and supports the ```Number``` item and is in the ```Time``` category. ## Device Configuration The following table provides a summary of the 34 configuration parameters available in the ADC-T 2000. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | HVAC System Type | Configures the type of heating system used. | | 2 | Number of Heat Stages | Heat Stages 0-3 Default is 2. | | 3 | Number of Cool Stages | Cool Stages 0-2 Default is 2. | | 4 | Heat Fuel Type | Choose type of fuel. Reality - whether unit is boiler vs forced air. | | 5 | Calibration Temperature | Calibration Temperature Range (in deg. F) Precision is tenths of a degree. | | 6 | Overshoot | Overshoot Range (in deg. F) Precision is tenths of a degree. Default is 5. | | 7 | Swing | Swing Range (in deg. F) Precision is tenths of a degree. | | 8 | Heat Staging Delay | Heat Staging Delay (in min) | | 9 | Cool Staging Delay | Cool Staging Delay (in min) | | 10 | Balance Setpoint | Balance Setpont Range (in deg. F) Precision is tenths of a degree. | | 11 | Recovery Settings | Whether thermostat uses intelligence to try and make the best of energy usage. | | 12 | Fan Circulation Period | Fan Circulation Period (in min) | | 13 | Fan Circulation Duty Cycle | Duty Cycle (percentage) | | 14 | Fan Purge Time | Purge Time (in s) | | 15 | Maximum Heat Setpoint | Max Heat Setpoint Range (in deg. F) Precision is tenths of a degree. | | 16 | Minimum Heat Setpoint | Min Heat Setpoint Range (in deg. F) Precision is tenths of a degree. | | 17 | Maximum Cool Setpoint | Max Cool Setpoint Range(in deg. F) Precision is tenths of a degree. | | 18 | Minimum Cool Setpoint | Min Cool Setpoint (in deg. F) Precision is tenths of a degree. | | 19 | Thermostat Lock | Lock out physical thermostat controls. | | 20 | Compressor Delay | Compressor Delay (in min) | | 21 | Demand Response Period | Demand Response Period (in min) | | 22 | Demand Response Duty Cycle | Demand Response Duty Cycle (percentage) | | 23 | Temperature Display Units | Celsius or Farenheit for temperature display. | | 24 | HVAC Modes Enabled | Which heating/cooling modes are available. | | 25 | Configurable Terminal Setting | Changes control of configurable terminal | | 26 | Power Source | Which source of power is utilized. | | 27 | Battery Alert Threshold Low | Battery Alert Range (percentage) | | 28 | Battery Alert Threshold Very Low | Very Low Battery Alert Range (percentage) | | 30 | Remote Temperature Enable | Enables remote temperature sensor instead of built-in. | | 31 | Heat Differential | Heat Differential (in deg. F) Precision is tenths of a degree. | | 32 | Cool Differential | Cool Differential (in deg. F) Precision is tenths of a degree. | | 33 | Temperature Reporting Threshold | Temperature Reporting Range (in deg. F) Precision is tenths of a degree. | | 34 | O/B Select | Configuration of O/B terminal. | | 35 | Z-Wave Echo Association Reports | Enable/Disabled Echo Assoc. Reports. | ### Parameter 1: HVAC System Type Configures the type of heating system used. 0 - Normal (Default) 1 - Heat Pump The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal | | 1 | Heat Pump | The manufacturer defined default value is ```0``` (Normal). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Number of Heat Stages Heat Stages 0-3 Default is 2. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 3 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Number of Cool Stages Cool Stages 0-2 Default is 2. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Heat Fuel Type Choose type of fuel. Reality - whether unit is boiler vs forced air. 0 - Fossil Fuel 1 - Electric (Default) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Fossil Fuel | | 1 | Electric | The manufacturer defined default value is ```1``` (Electric). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Calibration Temperature Calibration Temperature Range (in deg. F) Precision is tenths of a degree. Values in the range -100 to 100 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_5_4``` and is of type ```INTEGER```. ### Parameter 6: Overshoot Overshoot Range (in deg. F) Precision is tenths of a degree. Default is 5. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 30 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_6_4``` and is of type ```INTEGER```. ### Parameter 7: Swing Swing Range (in deg. F) Precision is tenths of a degree. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 30 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_7_4``` and is of type ```INTEGER```. ### Parameter 8: Heat Staging Delay Heat Staging Delay (in min) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 60 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Cool Staging Delay Cool Staging Delay (in min) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 60 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Balance Setpoint Balance Setpont Range (in deg. F) Precision is tenths of a degree. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 950 may be set. The manufacturer defined default value is ```350```. This parameter has the configuration ID ```config_10_4``` and is of type ```INTEGER```. ### Parameter 11: Recovery Settings Whether thermostat uses intelligence to try and make the best of energy usage. 0 - Comfort 1 - Efficient (Default) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Comfort | | 1 | Efficient | The manufacturer defined default value is ```1``` (Efficient). This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Fan Circulation Period Fan Circulation Period (in min) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 10 to 240 may be set. The manufacturer defined default value is ```20```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Fan Circulation Duty Cycle Duty Cycle (percentage) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```25```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Fan Purge Time Purge Time (in s) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 3600 may be set. The manufacturer defined default value is ```60```. This parameter has the configuration ID ```config_14_2``` and is of type ```INTEGER```. ### Parameter 15: Maximum Heat Setpoint Max Heat Setpoint Range (in deg. F) Precision is tenths of a degree. Values in the range 350 to 950 may be set. The manufacturer defined default value is ```950```. This parameter has the configuration ID ```config_15_4``` and is of type ```INTEGER```. ### Parameter 16: Minimum Heat Setpoint Min Heat Setpoint Range (in deg. F) Precision is tenths of a degree. Values in the range 350 to 950 may be set. The manufacturer defined default value is ```350```. This parameter has the configuration ID ```config_16_4``` and is of type ```INTEGER```. ### Parameter 17: Maximum Cool Setpoint Max Cool Setpoint Range(in deg. F) Precision is tenths of a degree. Values in the range 500 to 950 may be set. The manufacturer defined default value is ```950```. This parameter has the configuration ID ```config_17_4``` and is of type ```INTEGER```. ### Parameter 18: Minimum Cool Setpoint Min Cool Setpoint (in deg. F) Precision is tenths of a degree. Values in the range 500 to 950 may be set. The manufacturer defined default value is ```500```. This parameter has the configuration ID ```config_18_4``` and is of type ```INTEGER```. ### Parameter 19: Thermostat Lock Lock out physical thermostat controls. 0 - Disabled (Default) 1 - Enabled The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ### Parameter 20: Compressor Delay Compressor Delay (in min) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 60 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 21: Demand Response Period Demand Response Period (in min) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 10 to 240 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_21_1``` and is of type ```INTEGER```. ### Parameter 22: Demand Response Duty Cycle Demand Response Duty Cycle (percentage) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```25```. This parameter has the configuration ID ```config_22_1``` and is of type ```INTEGER```. ### Parameter 23: Temperature Display Units Celsius or Farenheit for temperature display. 0 - Celsius 1 - Farenheit (Default) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Celsius | | 1 | Farenheit | The manufacturer defined default value is ```1``` (Farenheit). This parameter has the configuration ID ```config_23_1``` and is of type ```INTEGER```. ### Parameter 24: HVAC Modes Enabled Which heating/cooling modes are available. 3 - Off, Heat 5 - Off, Cool 7 - Off, Heat, Cool 15 - Off, Heat, Cool, Auto (Default) 19 - Off, Heat, Emergency Heat 23 - Off, Heat, Cool, Emergency Heat 31 - Off, Heat, Cool, Auto, Emergency Heat The following option values may be configured -: | Value | Description | |--------|-------------| | 3 | Off, Heat | | 5 | Off, Cool | | 7 | Off, Heat, Cool | | 15 | Off, Heat, Cool, Auto (Default) | | 19 | Off, Heat, Emergency Heat | | 23 | Off, Heat, Cool, Emergency Heat | | 31 | Off, Heat, Cool, Auto, Emergency Heat | The manufacturer defined default value is ```15``` (Off, Heat, Cool, Auto (Default)). This parameter has the configuration ID ```config_24_1``` and is of type ```INTEGER```. ### Parameter 25: Configurable Terminal Setting Changes control of configurable terminal 0 - Disabled (Default) 1 - W3 - Third Stage HEAT or 2nd Stage of 2-Stage Auxiliary / Backup heat 2 - H - External Dehumidifier Control 3 - DH - External Dehumidifier Operation The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | W3 | | 2 | H | | 3 | DH | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_25_1``` and is of type ```INTEGER```. ### Parameter 26: Power Source Which source of power is utilized. 0 - Battery (Default) 1 - C-Wire The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Battery | | 1 | C-Wire | The manufacturer defined default value is ```0``` (Battery). This parameter has the configuration ID ```config_26_1``` and is of type ```INTEGER```. ### Parameter 27: Battery Alert Threshold Low Battery Alert Range (percentage) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_27_1``` and is of type ```INTEGER```. ### Parameter 28: Battery Alert Threshold Very Low Very Low Battery Alert Range (percentage) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```15```. This parameter has the configuration ID ```config_28_1``` and is of type ```INTEGER```. ### Parameter 30: Remote Temperature Enable Enables remote temperature sensor instead of built-in. 0 - Disabled (Default) 1 - EnabledThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_30_1``` and is of type ```INTEGER```. ### Parameter 31: Heat Differential Heat Differential (in deg. F) Precision is tenths of a degree. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 10 to 100 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_31_4``` and is of type ```INTEGER```. ### Parameter 32: Cool Differential Cool Differential (in deg. F) Precision is tenths of a degree. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 10 to 100 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_32_4``` and is of type ```INTEGER```. ### Parameter 33: Temperature Reporting Threshold Temperature Reporting Range (in deg. F) Precision is tenths of a degree. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 20 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_33_4``` and is of type ```INTEGER```. ### Parameter 34: O/B Select Configuration of O/B terminal. 0 - O/B Terminal acts as B terminal, closed when cooling 1 - O/B Terminal acts as O terminal, closed when heating (Default)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | O/B as B | | 1 | O/B as O | The manufacturer defined default value is ```1``` (O/B as O). This parameter has the configuration ID ```config_34_1``` and is of type ```INTEGER```. ### Parameter 35: Z-Wave Echo Association Reports Enable/Disabled Echo Assoc. Reports. 0 - Disabled (Default) 1 - EnabledThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_35_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ADC-T 2000 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Association group 1 supports 4 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V6| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [Product Manual](https://opensmarthouse.org/zwavedatabase/926/reference/Smart-Thermostat-Product-Manual1.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/926).