--- layout: documentation title: FGS211 - ZWave --- {% include base.html %} # FGS211 Relay Switch 1x3kW This describes the Z-Wave device *FGS211*, manufactured by *[Fibargroup](http://www.fibaro.com/)* with the thing type UID of ```fibaro_fgs211_00_000```. This version of the device is limited to firmware versions below 2.0 The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![FGS211 product image](https://opensmarthouse.org/zwavedatabase/120/image/) The FGS211 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Remotely Controlled Relay Switch of Fibaro System is designed to operate in a wall switch box or in locations where the control of an electric device (up to 3kW) is needed. It is also possible to send a signal to any system that is to be integrated with Fibaro system. ### Inclusion Information Add Fibaro Switch to the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes. ### Exclusion Information Remove Fibaro Switch from the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes. ## Channels The following table summarises the channels available for the FGS211 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch 1 | switch_binary1 | switch_binary | Switch | Switch | | Switch 2 | switch_binary2 | switch_binary | Switch | Switch | ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 13 configuration parameters available in the FGS211. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Enable/Disable ALL ON/OFF | Activate/Deactive ALL ON/OFF | | 3 | Enable/Disable OFF-delay | Activate/Deactivate Automatic turning off relay after set time | | 4 | Relay 1: OFF-delay time (10ms steps) | Automatic turning off relay 1 after set time | | 6 | Separation of association sending (key 1) | Activate/Deactivate association sending for group 1 - Also see param #16 | | 13 | Inputs behaviour | In case of bi-stable switches, define their behaviour (toggle or follow) | | 14 | Inputs Button/Switch configuration | Binary inputs type configuration | | 15 | Dimmer/Roller shutter control | Enable/Disable operation associated to group 1. | | 16 | Saving state before power failure | Saving state before power failure | | 30 | Relay 1: Response to General Alarm | | | 31 | Relay 1: Response to Water Flood Alarm | | | 32 | Relay 1: Response to Smoke, CO, CO2 Alarm | | | 33 | Relay 1: Response to Temperature Alarm | | | 39 | ALARM FLASHING alarm time | Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame | ### Parameter 1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF The following option values may be configured -: | Value | Description | |--------|-------------| | -1 | ALL ON active / ALL OFF active | | 0 | ALL ON disabled / ALL OFF disabled | | 1 | ALL ON disabled / ALL OFF active | | 2 | ALL ON active / ALL OFF disabled | The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 3: Enable/Disable OFF-delay Activate/Deactivate Automatic turning off relay after set time The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Auto OFF disabled for both relays | | 1 | Auto OFF active only for relay 1 | The manufacturer defined default value is ```0``` (Auto OFF disabled for both relays). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Relay 1: OFF-delay time (10ms steps) Automatic turning off relay 1 after set time Automatic turning off relay 1 after set time, in 10ms increments (default: 200ms) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```20```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 6: Separation of association sending (key 1) Activate/Deactivate association sending for group 1 - Also see param #16 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Map status to all devices in group 1 | | 1 | Map OFF status to devices in group 1-last state | | 2 | Map OFF status to devices in group 1 - 100% | The manufacturer defined default value is ```0``` (Map status to all devices in group 1). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 13: Inputs behaviour In case of bi-stable switches, define their behaviour (toggle or follow) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Toggle | | 1 | Follow switch contact (closed=ON, open=OFF) | The manufacturer defined default value is ```0``` (Toggle). This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Inputs Button/Switch configuration Binary inputs type configuration The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Mono-stable input (button) | | 1 | Bi-stable input (switch) | The manufacturer defined default value is ```1``` (Bi-stable input (switch)). This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: Dimmer/Roller shutter control Enable/Disable operation associated to group 1. Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable Dimmer/Roller shutter control | | 1 | Enable Dimmer/Roller shutter control | The manufacturer defined default value is ```0``` (Disable Dimmer/Roller shutter control). This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 16: Saving state before power failure Saving state before power failure The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | State NOT saved at power failure | | 1 | State saved at power failure | The manufacturer defined default value is ```1``` (State saved at power failure). This parameter has the configuration ID ```config_16_1``` and is of type ```INTEGER```. ### Parameter 30: Relay 1: Response to General Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING | The manufacturer defined default value is ```3``` (ALARM FLASHING). This parameter has the configuration ID ```config_30_1``` and is of type ```INTEGER```. ### Parameter 31: Relay 1: Response to Water Flood Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING | The manufacturer defined default value is ```2``` (Alarm relay OFF). This parameter has the configuration ID ```config_31_1``` and is of type ```INTEGER```. ### Parameter 32: Relay 1: Response to Smoke, CO, CO2 Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING | The manufacturer defined default value is ```3``` (ALARM FLASHING). This parameter has the configuration ID ```config_32_1``` and is of type ```INTEGER```. ### Parameter 33: Relay 1: Response to Temperature Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING | The manufacturer defined default value is ```1``` (Alarm relay ON). This parameter has the configuration ID ```config_33_1``` and is of type ```INTEGER```. ### Parameter 39: ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_39_2``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The FGS211 supports 3 association groups. ### Group 1: Switch 1 Association group 1 supports 16 nodes. ### Group 2: Switch 2 Association group 2 supports 16 nodes. ### Group 3: Controller Updates Association group 3 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| ### Documentation Links * [User Manual v1.03](https://opensmarthouse.org/zwavedatabase/120/reference/FGS-211-EN-A-v1-03.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/120).