--- layout: documentation title: DSC12 - ZWave --- {% include base.html %} # DSC12 Micro Smart Energy Switch This describes the Z-Wave device *DSC12*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc12_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![DSC12 product image](https://opensmarthouse.org/zwavedatabase/277/image/) The DSC12 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Aeon Labs Micro SES is a binary power switch device based on Zwave enhanced slave library V5.02P3. ### Inclusion Information Click the button once. ### Exclusion Information Click the button once. ## Channels The following table summarises the channels available for the DSC12 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Sensor (power) | sensor_power | sensor_power | Energy | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Sensor (power) Indicates the energy consumption (kWh). The ```sensor_power``` channel is of type ```sensor_power``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 13 configuration parameters available in the DSC12. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Make Micro Smart Switch Blink | | | 3 | Current Overload Protection | | | 80 | Notification on Status Change | | | 90 | Enable Automated sending of a Report | Automated sending of a Report triggered by minimal change of value. | | 91 | Minimum Change to send Report (Watt) | | | 92 | Minimum Change to send Report (%) | | | 101 | Automatic reports for group 1 | Which reports need to send automatically in timing intervals for group 1 | | 102 | Automatic reports for group 2 | Which reports need to send automatically in timing intervals for group 2 | | 103 | Automatic reports for group 3 | Which reports need to send automatically in timing intervals for group 3 | | 111 | Interval to send out reports of group 1 | | | 112 | Interval to send out reports of group 2 | | | 113 | Interval to send out reports of group 3 | | | 120 | Turn External Button Mode | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 2: Make Micro Smart Switch Blink Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Current Overload Protection The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deactivate | | 1 | Activate | The manufacturer defined default value is ```0``` (Deactivate). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 80: Notification on Status Change The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deactivate | | 1 | Hail CC Sent | | 2 | Basic CC Report Sent | The manufacturer defined default value is ```0``` (Deactivate). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 90: Enable Automated sending of a Report Automated sending of a Report triggered by minimal change of value. Automated sending of a Report triggered by minimal change of value. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deactivate | | 1 | Activate | The manufacturer defined default value is ```0``` (Deactivate). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Minimum Change to send Report (Watt) Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```25```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Minimum Change to send Report (%) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 101: Automatic reports for group 1 Which reports need to send automatically in timing intervals for group 1 Which reports need to send automatically in timing intervals for group 1 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Automatic reports for group 2 Which reports need to send automatically in timing intervals for group 2 Which reports need to send automatically in timing intervals for group 2 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```8```. This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Automatic reports for group 3 Which reports need to send automatically in timing intervals for group 3 Which reports need to send automatically in timing intervals for group 3 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 111: Interval to send out reports of group 1 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Interval to send out reports of group 2 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Interval to send out reports of group 3 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Parameter 120: Turn External Button Mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Momentary Button Mode | | 1 | 2 State Switch Mode | | 2 | 3 Way Switch Mode | The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_120_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSC12 supports 2 association groups. ### Group 1: Target for automatic meter reports Association group 1 supports 5 nodes. ### Group 2: Target for automatic reports Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V3| | | COMMAND_CLASS_METER_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Spec Sheet](https://opensmarthouse.org/zwavedatabase/277/reference/Micro-Smart-Energy-Switch.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/277).