--- layout: documentation title: ZEN24 - ZWave --- {% include base.html %} # ZEN24 Toggle Dimmer v3 This describes the Z-Wave device *ZEN24*, manufactured by *[Zooz](http://www.getzooz.com/)* with the thing type UID of ```zooz_zen24_03_000```. This version of the device is limited to firmware versions 3.0 to 3.255 The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![ZEN24 product image](https://opensmarthouse.org/zwavedatabase/1160/image/) The ZEN24 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview * Manual or Z-Wave on/off and brightness control * **Direct 3-way:** worke with regular on/off switches in a 3-way (neutral wire required) * Fully adjustable ramp rate for just the right on/off speed * Double tap to full brightness feature * **NEW:** optional scene control * Remembers and restores on/off status after power failure * Built-in Z-Wave Plus signal repeater to extend network range * Works with LED and incandescent bulbs (don't use with fans or tubes) ### Inclusion Information Toggle the switch up 5 or 6 times very quickly when adding it. ### Exclusion Information Toggle the switch down 3 times quickly ## Channels The following table summarises the channels available for the ZEN24 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | scene_number | | Number | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ## Device Configuration The following table provides a summary of the 13 configuration parameters available in the ZEN24. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Toggle Control | Controls behavior of the toggle switch | | 3 | Auto Turn-Off Timer Enable | Auto Turn-Off Timer Enable | | 4 | Auto Turn-Off Timer Time | Auto Turn-Off Timer Time | | 5 | Auto Turn-On Timer Enable | Auto Turn-On Timer Enable | | 6 | Auto Turn-On Timer Time | Auto Turn-On Timer Time | | 8 | Status after Power Failure | Status after Power Failure | | 9 | Ramp Rate Control | Ramp Rate Control | | 10 | Minimum Brightness | Minimum Brightness | | 11 | Maximum Brightness | Maximum Brightness | | 12 | Double Tap Function | Double Tap Function | | 13 | Scene Control Enable | Scene Control Enable | | 14 | Double & Single Tap Enable | Double & Single Tap Enable | | 15 | Local Toggle Control | Local Toggle Control | ### Parameter 1: Toggle Control Controls behavior of the toggle switch Choose if you want the to turn the light on by clicking the toggle up or down. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | UP turns light ON | | 1 | DOWN turns light ON | The manufacturer defined default value is ```0``` (UP turns light ON). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 3: Auto Turn-Off Timer Enable Auto Turn-Off Timer Enable Enable or disable the auto turn-off timer function. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Timer Disabled | | 1 | Timer Enabled | The manufacturer defined default value is ```0``` (Timer Disabled). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Auto Turn-Off Timer Time Auto Turn-Off Timer Time The number is in minutes. Default: 60 minutes Values in the range 1 to 65535 may be set. The manufacturer defined default value is ```60```. This parameter has the configuration ID ```config_4_4``` and is of type ```INTEGER```. ### Parameter 5: Auto Turn-On Timer Enable Auto Turn-On Timer Enable enable or disable the auto turn-on timer function. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Timer Disabled | | 1 | Timer Enabled | The manufacturer defined default value is ```0``` (Timer Disabled). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Auto Turn-On Timer Time Auto Turn-On Timer Time number is in minutes Default: 60 minutes Values in the range 1 to 65535 may be set. The manufacturer defined default value is ```60```. This parameter has the configuration ID ```config_6_4``` and is of type ```INTEGER```. ### Parameter 8: Status after Power Failure Status after Power Failure The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Off | | 1 | On | | 2 | Restore Previous Status | The manufacturer defined default value is ```2``` (Restore Previous Status). This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Ramp Rate Control Ramp Rate Control Number of seconds for the dimmer to reach full brightness or turn off when operated manually. Default: 1 second Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Minimum Brightness Minimum Brightness Minimum brightness level (in %) for your dimmer. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Maximum Brightness Maximum Brightness Maximum brightness level (in %) for your dimmer. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```99```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Double Tap Function Double Tap Function The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Full Brightness | | 1 | Maximum Brightness Level (Parameter 11) | The manufacturer defined default value is ```0``` (Full Brightness). This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Scene Control Enable Scene Control Enable Enable or disable scene control for quick double tap triggers. Find out how to make scene control work at www.support.getzooz.comThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Scene Control Disabled | | 1 | Scene Control Enabled | The manufacturer defined default value is ```0``` (Scene Control Disabled). This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Double & Single Tap Enable Double & Single Tap Enable Enable or disable the double-tap function and assign brightness level to single tap.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Double Tap Enabled | | 1 | DT Disabled, Single Tap last brightness | | 2 | DT Disabled, Single Tap to Full / Max Bruightness | The manufacturer defined default value is ```0``` (Double Tap Enabled). This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: Local Toggle Control Local Toggle Control The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Local control DISABLED | | 1 | Local control ENABLED | The manufacturer defined default value is ```1``` (Local control ENABLED). This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ZEN24 supports 2 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 1 node. ### Group 2: Group 2 sends BASIC SET Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1160/reference/zooz-z-wave-plus-toggle-dimmer-zen24-ver3-manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1160).