--- layout: documentation title: XL624 - ZWave --- {% include base.html %} # XL624 Touchscreen Comfort Control Thermostat This describes the Z-Wave device *XL624*, manufactured by *Trane Corporation* with the thing type UID of ```trane_xl624_00_000```. The device is in the category of *HVAC*, defining Air condition devices, Fans. ![XL624 product image](https://opensmarthouse.org/zwavedatabase/282/image/) The XL624 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Trane 624 Touchscreen Comfort Control is compatible with single and multistage forced air systems, including: * Gas furnace systems * Oil furnace systems * Electric furnace systems * Heat pump systems * Air conditioning systems ### Inclusion Information 1. Press MENU on the 624 Control. 2. Press NEXT to advance to the Z-WAVE menu. 3. Press SELECT ### Exclusion Information 1. Press MENU on the 624 Control. 2. Press NEXT to scroll to Z-WAVE screen then press SELECT. 3. Press YES to exclude the control ## Channels The following table summarises the channels available for the XL624 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number | | Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature | | Sensor (general) | sensor_general | sensor_general | | Number | | Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number | | Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature | | Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | | | | Thermostat fan state | thermostat_fanstate | thermostat_fanstate | | | ### Sensor (relative humidity) Indicates the current relative humidity. The ```sensor_relhumidity``` channel is of type ```sensor_relhumidity``` and supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device. ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Sensor (general) The ```sensor_general``` channel is of type ```sensor_general``` and supports the ```Number``` item. This is a read only channel so will only be updated following state changes from the device. ### Thermostat mode Sets the thermostat. The ```thermostat_mode``` channel is of type ```thermostat_mode``` and supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Setpoint (cooling) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Setpoint (heating) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category. ### Thermostat fan mode Channel type information on this channel is not found. ### Thermostat fan state Channel type information on this channel is not found. ## Device Configuration The following table provides a summary of the 4 configuration parameters available in the XL624. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 10 | Minimum Off Time | Minimum Off Time | | 11 | Minimum Run Time | Minimum Run Time | | 12 | Heating Delta Stage 1 ON | Heating Delta Stage 1 ON | | 13 | Heating Delta Stage 1 OFF | Heating Delta Stage 1 OFF | ### Parameter 10: Minimum Off Time Minimum Off Time Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 9 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Minimum Run Time Minimum Run Time Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 9 may be set. The manufacturer defined default value is ```6```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Heating Delta Stage 1 ON Heating Delta Stage 1 ON Sets the delta from setpoint that stage 1 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Heating Delta Stage 1 OFF Heating Delta Stage 1 OFF Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_MULTI_CMD_V1| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/282/reference/72-1286-04-RO.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/282).