--- layout: documentation title: NZW36 - ZWave --- {% include base.html %} # NZW36 On/Off Smart Plug + Signal Repeater (Z-Wave Plus) This describes the Z-Wave device *NZW36*, manufactured by *NIE Technology* with the thing type UID of ```nietech_nzw36_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![NZW36 product image](https://opensmarthouse.org/zwavedatabase/831/image/) The NZW36 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview **Plug the Smart Outlet in. Sync. Control Lights & Appliances from Anywhere.** **Control your lights and appliances** with the Inovelli® **Z-Wave Plus** plug-in on/off smart outlet. In addition to being able to remotely control your devices, this smart plug also acts as a Z-Wave signal booster (repeater), giving you best of both worlds. ### Inclusion Information Alright, let’s include your device! **Including Steps:** * Go ahead and put your HUB/Gateway in inclusion/pairing mode * While your HUB/Gateway is in inclusion mode, press the Middle Button on the front of your NZW36 five (5) times rapidly within 1-2 seconds Check to make sure your device turns on and off and if so, congratulations, you now have remote control over your lights! **STILL CAN’T GET IT TO PAIR?** You may need to exclude the device first. While this is rare, sometimes it happens. Please click see the, “Exclusion / Device Removal” section below. Once that’s completed, please return here. **\*\*If you are having issues pairing your device, please make sure you are within range above. If you are confident you are, please click on the, “Exclusion / Device Removal” tab below to exclude your device first\*\*** ### Exclusion Information Please follow the below directions to exclude/remove your smart plug from your HUB/Gateway. **Exclusion/Removal Steps:** * Put your HUB/Gateway in exclusion/removal mode * Press the Middle Button on the front of your NZW36 five (5) times rapidly (within 1-2 seconds) Your smart plug should now be removed from your HUB/Gateway. **\*\*If you are having issues removing your device, try removing the device directly next to the HUB. This will solve 95% of all problems you may have when removing\*\*** ## Channels The following table summarises the channels available for the NZW36 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Scene Number | scene_number | scene_number | | Number | | Alarm | alarm_general | alarm_general | Alarm | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 2 configuration parameters available in the NZW36. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | LED Indicator | | | 2 | Countdown | Plug Auto Shut Off | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: LED Indicator The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Plug On / LED On | | 1 | Plug On / LED Off | | 2 | LED Disabled | The manufacturer defined default value is ```0``` (Plug On / LED On). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Countdown Plug Auto Shut Off Plug auto shutoff 0 - 36000 seconds Values in the range 0 to 36000 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The NZW36 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_TRANSPORT_SERVICE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_SUPERVISION_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_SECURITY_V1| | | COMMAND_CLASS_SECURITY_2_V1| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/831/reference/NZW36-Manual-1.pdf) * [Another Manual](https://opensmarthouse.org/zwavedatabase/831/reference/NZW36-Manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/831).