--- layout: documentation title: MS11Z - ZWave --- {% include base.html %} # MS11Z Minoston Smart Dimmer Switch This describes the Z-Wave device *MS11Z*, manufactured by *NIE Technology* with the thing type UID of ```nietech_ms11z_04_000```. This version of the device is limited to firmware version 4.0 The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![MS11Z product image](https://opensmarthouse.org/zwavedatabase/1231/image/) The MS11Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview In-Wall Switch (Dimmer) ### Inclusion Information Add  the MS13Z from the existing Z-Wave home control network with your primary controller. *  Refer to your primary controller instructions to process the inclusion / exclusion setup procedure. *  When prompted by your primary controller, click the Up or Down button three times in one second. Include MS13Z to/from a Z-Wave Gateway with supporting Security.The MS13Z can support the Primary Controller that implemented the security S2. ### Exclusion Information Remove the MS13Z from the existing Z-Wave home control network with your primary controller. *  Refer to your primary controller instructions to process the inclusion / exclusion setup procedure. *  When prompted by your primary controller, click the Up or Down button three times in one second. ## Channels The following table summarises the channels available for the MS11Z -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | scene_number | | Number | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ## Device Configuration The following table provides a summary of the 5 configuration parameters available in the MS11Z. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Locally button function | Locally button function | | 2 | LED indicator | LED indicator | | 3 | Enable Auto Turn-Off Timer | Enable Auto Turn-Off Timer | | 4 | Auto turn off timer | Auto turn off timer | | 6 | Restore state after power failure | Restore state after power failure | ### Parameter 1: Locally button function Locally button function Parameter=1 Size=1 Value=0 Up Button:On Down Button: Off Value=1 Up Button:Off Down Button: On Value=2 Up Button:On/Off Down Button: On/Off Default = 0 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Up Button:On Down Button: Off | | 1 | Up Button:Off Down Button: On | | 2 | Up Button:On/Off Down Button: On/Off | The manufacturer defined default value is ```0``` (Up Button:On Down Button: Off). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: LED indicator LED indicator Parameter=2 Size=1 Value=0 On when Off and Off when On Value=1 On when On and Off when Off Value=2 Always Off Value=3 Always On Default =0  The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | On when Off and Off when On | | 1 | On when On and Off when Off | | 2 | Always Off | | 3 | Always On | The manufacturer defined default value is ```0``` (On when Off and Off when On ). This parameter has the configuration ID ```config_2_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 3: Enable Auto Turn-Off Timer Enable Auto Turn-Off Timer Value=0 Timer disabled (default) Value=1 Timer enabled  The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Auto turn off timer Auto turn off timer  0 – 65535 (M); default 0M Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_4_4``` and is of type ```INTEGER```. ### Parameter 6: Restore state after power failure Restore state after power failure Values in the range 0 to 2 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The MS11Z supports 2 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ### Group 2: Send Basic Set ON/OFF Association group 2 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1231/ZW-31manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1231).