--- layout: documentation title: MH-C221 - ZWave --- {% include base.html %} # MH-C221 MCO HOME Micro Shutter This describes the Z-Wave device *MH-C221*, manufactured by *[McoHome Technology Co., Ltd](http://www.mcohome.com/)* with the thing type UID of ```mcohome_c221_00_000```. The device is in the category of *Blinds*, defining Roller shutters, window blinds, etc.. ![MH-C221 product image](https://opensmarthouse.org/zwavedatabase/1038/image/) The MH-C221 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview MCO HOME Micro Shutter for windows roller shutter The device allows for controlling motors of roller blinds, awnings, venetian blinds, gates and others, which are single phase AC powered. This Roller Shutter allows for precise positioning of a roller blind or  venetian blind lamellas. Precise positioning is available for the motors equipped with mechanic and electronic end switches. The module may be controlled wirelessly, through the Z-Wave network main controller, or through the switch keys connected to it. It’s also possible to combine few devices into groups of devices, which then can be controlled simultaneously. In addition, this Roller Shutter is equipped with Power Metering. ### Inclusion Information 1. Connect the power supply. 2. Set the main controller into the learn mode (see main controllers operating manual). 3. Triple click the B-button or a push button connected to the S1 terminal. 4. MCO Home Roller Shutter will be detected and included into the Z-Wave network ### Exclusion Information 1. Make sure the module is connected to the power supply. 2. Set the main controller into the learn mode (see main controllers operating manual). 3. Triple click the B-button or a push button connected to the S1 terminal. ### General Usage Information Control roller shutters, garage door... ## Channels The following table summarises the channels available for the MH-C221 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | switch_binary | switch_binary | switch_binary | Switch | Switch | | blinds control | blinds_control | blinds_control | Blinds | Rollershutter | | Electric Meter (Watts) 1 | meter_watts | meter_watts | Energy | Number | | Electric Meter (Volts) | meter_voltage | meter_voltage | Energy | Number | | Electric Meter (amp) | meter_current | meter_current | Energy | Number | | Electric Meter (Kwh) | meter_kwh | meter_kwh | Energy | Number | | Alarm | alarm_general | alarm_general | Alarm | Switch | ### switch_binary Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### blinds control Provides start / stop control of blinds. The ```blinds_control``` channel is of type ```blinds_control``` and supports the ```Rollershutter``` item and is in the ```Blinds``` category. ### Electric Meter (Watts) 1 Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric Meter (Volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric Meter (amp) Indicates the instantaneous current consumption. The ```meter_current``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric Meter (Kwh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 13 configuration parameters available in the MH-C221. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Watt meter report period | Watt meter report period | | 2 | KHW meter report period | KHW meter report period:Unit 10min,6*10min=1h | | 3 | Threshold of current load - Caution | Unit 0.01A 500*0.01A=5A | | 4 | Watt meter report period | Watt meter report period | | 5 | Level Report mode | 1: Report destination in 5s interval: 2: report every 10% level charge | | 7 | Demo trip | 1:activate demo trip and calibration when first touch of the button | | 9 | Demo trip and calibration | 1:activate demo trip and calibration | | 10 | A: Auto Calibratio | 1:activate calibration only | | 11 | B: Min level of the shutter close | 0-98 | | 12 | C: Max Level of shutter open | 1-99 | | 13 | D: External switch type | 0: Button (momentary buttons) 1: toggle (2-state switches) on position-shutter open off position -shutter close 2: toggle (2-state switches) on position-shutter close off postion - shutter open | | 14 | E: External switch input | 0: no external switch 1: wire 1 ex, momentary or toggle key to S1 only 2: wire 1 ex, momentary or toggle key to S2 only 3: wire 2 ex, momentary or toggle keys to S1 and S2, each key can control both directions 4: wire 2 | | 255 | FF: Factory Setting | 85 restore factory setting | ### Parameter 1: Watt meter report period Watt meter report period Values in the range 1 to 32767 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_1_2``` and is of type ```INTEGER```. ### Parameter 2: KHW meter report period KHW meter report period:Unit 10min,6*10min=1h Values in the range 1 to 32767 may be set. The manufacturer defined default value is ```6```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Threshold of current load - Caution Unit 0.01A 500*0.01A=5A Values in the range 10 to 500 may be set. The manufacturer defined default value is ```500```. This parameter has the configuration ID ```config_3_2``` and is of type ```INTEGER```. ### Parameter 4: Watt meter report period Watt meter report period Values in the range 1 to 10000 may be set. The manufacturer defined default value is ```10000```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 5: Level Report mode 1: Report destination in 5s interval: 2: report every 10% level charge Values in the range 1 to 2 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: Demo trip 1:activate demo trip and calibration when first touch of the button Values in the range 0 to 1 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 9: Demo trip and calibration 1:activate demo trip and calibration Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: A: Auto Calibratio 1:activate calibration only Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: B: Min level of the shutter close 0-98 Values in the range 0 to 98 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: C: Max Level of shutter open 1-99 Values in the range 1 to 99 may be set. The manufacturer defined default value is ```99```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: D: External switch type 0: Button (momentary buttons) 1: toggle (2-state switches) on position-shutter open off position -shutter close 2: toggle (2-state switches) on position-shutter close off postion - shutter open Values in the range 0 to 2 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: E: External switch input 0: no external switch 1: wire 1 ex, momentary or toggle key to S1 only 2: wire 1 ex, momentary or toggle key to S2 only 3: wire 2 ex, momentary or toggle keys to S1 and S2, each key can control both directions 4: wire 2 Values in the range 1 to 4 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 255: FF: Factory Setting 85 restore factory setting Values in the range 0 to 85 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_255_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The MH-C221 supports 3 association groups. ### Group 1: Group 1 Association group 1 supports 1 node. ### Group 2: Group 2 Association group 2 supports 1 node. ### Group 3: Group 3 Association group 3 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/1038/reference/User-Manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1038).