--- layout: documentation title: LZW60 - ZWave --- {% include base.html %} # LZW60 4-in-1 motion sensor This describes the Z-Wave device *LZW60*, manufactured by *Inovelli* with the thing type UID of ```inovelli_lzw60_00_000```. The device is in the category of *Motion Detector*, defining Motion sensors/detectors. ![LZW60 product image](https://opensmarthouse.org/zwavedatabase/1204/image/) The LZW60 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The LZW60 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview * Light: Save energy by making sure lights don’t turn on if it’s bright enough. * Motion: Be notified when you’re away and automate your lighting. * Humidity: To avoid excess moisture, trigger fans and dehumidifiers. * Temperature: Smarter climate control by monitoring every room in your home. ### Inclusion Information Put your hub into inclusion mode and press the button on the back of the 4-in-1 sensor one time. ### Exclusion Information Put your hub into exclusion mode and press the button on the back of the 4-in-1 sensor one time. ### Wakeup Information The LZW60 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. To wake up the sensor so that your hub can send it configuration parameters quickly press on the button on the back 3 times. ## Channels The following table summarises the channels available for the LZW60 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature | | Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number | | Sensor (luminance) | sensor_luminance | sensor_luminance | | Number | | Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch | | Motion Alarm | alarm_motion | alarm_motion | Motion | Switch | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Sensor (relative humidity) Indicates the current relative humidity. The ```sensor_relhumidity``` channel is of type ```sensor_relhumidity``` and supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device. ### Sensor (luminance) Indicates the current light reading. The ```sensor_luminance``` channel is of type ```sensor_luminance``` and supports the ```Number``` item. This is a read only channel so will only be updated following state changes from the device. ### Alarm (burglar) Indicates if the burglar alarm is triggered. The ```alarm_burglar``` channel is of type ```alarm_burglar``` and supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Motion Alarm Indicates if a motion alarm is triggered. The ```alarm_motion``` channel is of type ```alarm_motion``` and supports the ```Switch``` item and is in the ```Motion``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The following table provides a summary of the 15 configuration parameters available in the LZW60. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 10 | Low Battery Power Level Alarm | Value at which sensor reports low battery to the gateway | | 12 | PIR Sensitivity | | | 13 | PIR Trigger Time | PIR Trigger Time (Time Between PIR Readings) | | 14 | Basic Set Command Send after PIR Trigger | Basic Set Command Send after PIR Trigger | | 15 | PIR Trigger Correspondence Action | PIR Trigger Correspondence Action | | 100 | Change Parameters 101-104 Back to Default Settings | Change Parameters 101-104 Back to Default Settings | | 101 | Temperature Reporting Interval | Temperature Reporting Interval | | 102 | Humidity Reporting Interval | Humidity Reporting Interval | | 103 | Luminance Reporting Interval | Luminance Reporting Interval | | 104 | Battery Reporting Interval | Battery Reporting Interval | | 110 | Send Reports According to Threshold | Only send sensor reports if the below thresholds are met | | 111 | Temperature Threshold | Temperature Threshold | | 112 | Humidity Threshold | Humidity Threshold | | 113 | Luminance Threshold | Luminance Threshold | | 114 | Battery Threshold | Battery Threshold | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | ### Parameter 10: Low Battery Power Level Alarm Value at which sensor reports low battery to the gateway Values in the range 10 to 50 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 12: PIR Sensitivity Values in the range 0 to 10 may be set. The manufacturer defined default value is ```8```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: PIR Trigger Time PIR Trigger Time (Time Between PIR Readings) The amount of seconds between motion detection (ie. interval) 5 = 5 seconds Values in the range 5 to 15300 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_13_2``` and is of type ```INTEGER```. ### Parameter 14: Basic Set Command Send after PIR Trigger Basic Set Command Send after PIR Trigger Should Basic Set Command be sent after PIR is triggered: 0=No, 1 = Yes Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: PIR Trigger Correspondence Action PIR Trigger Correspondence Action Ability to reverse the Basic Set behavior for devices associated in group 2. 0 = Turn the associated device ON when motion is tripped, and OFF when motion stops. 1 = Turn the associated device OFF when motion is tripped, and ON when motion stops. Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 100: Change Parameters 101-104 Back to Default Settings Change Parameters 101-104 Back to Default Settings If changes are made to parameters 101-104, you can set parameter 100 to 1 to reset 101-104 back to default. Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_100_1``` and is of type ```INTEGER```. ### Parameter 101: Temperature Reporting Interval Temperature Reporting Interval The interval between when temperature is reported to the gateway 0=Off, 1 = 1 second (Note: the sensor reporting time will round to the nearest minute) Values in the range 0 to 2678400 may be set. The manufacturer defined default value is ```7200```. This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Humidity Reporting Interval Humidity Reporting Interval The interval between when humidity is reported to the gateway 0 = Off, 1 = 1 second (Note: the sensor reporting time will round to the nearest minute) Values in the range 0 to 2678400 may be set. The manufacturer defined default value is ```7200```. This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Luminance Reporting Interval Luminance Reporting Interval The interval between when luminance is reported to the gateway 0 = Off, 1 = 1 second (Note: the sensor reporting time will round to the nearest minute) Values in the range 0 to 2678400 may be set. The manufacturer defined default value is ```7200```. This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 104: Battery Reporting Interval Battery Reporting Interval The interval between when battery is reported to the gateway 0 = Off, 1 = 1 second (Note: the sensor reporting time will round to the nearest minute) Values in the range 0 to 2678400 may be set. The manufacturer defined default value is ```86400```. This parameter has the configuration ID ```config_104_4``` and is of type ```INTEGER```. ### Parameter 110: Send Reports According to Threshold Only send sensor reports if the below thresholds are met Only send sensor reports if the below thresholds are met. 1:Yes, 0:No Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_110_1``` and is of type ```INTEGER```. ### Parameter 111: Temperature Threshold Temperature Threshold Set the threshold of the temperature for your sensor 1 = .1 degree Celsius (I know... wish it was Fahrenheit), 500 = 50 degrees Celsius Values in the range 1 to 500 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_111_2``` and is of type ```INTEGER```. ### Parameter 112: Humidity Threshold Humidity Threshold Set the threshold of the humidity for your sensor 1 = 1%, 2 = 2% Values in the range 1 to 32 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_112_1``` and is of type ```INTEGER```. ### Parameter 113: Luminance Threshold Luminance Threshold Set the threshold of the luminance for your sensor 1 = 1 unit lux, 2 = 2 unit lux Values in the range 1 to 65528 may be set. The manufacturer defined default value is ```150```. This parameter has the configuration ID ```config_113_2``` and is of type ```INTEGER```. ### Parameter 114: Battery Threshold Battery Threshold Set the threshold of the battery for your sensor 1 = 1%, 2 = 2% Values in the range 0 to 100 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_114_1``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The LZW60 supports 2 association groups. ### Group 1: Group 1 Sensor will send updates 1. Notification Report Sensor will send notification report when motion detection unknown location and (event inactive) 2. Multilevel Sensor Report Sensor will send multilevel sensor report (temperature, humidity, luminance) interval of 2 hours 3. Battery Report Sensor will send battery report when the battery level is low and the battery report's value is 0xFF 4. Device Reset Locally Association group 1 supports 5 nodes. ### Group 2: Group 2 Send Basic Set when PIR is triggered Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V8| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Manual (edited)](https://opensmarthouse.org/zwavedatabase/1204/reference/LZW60-Manual-edited.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1204).