--- layout: documentation title: GE 46202 - ZWave --- {% include base.html %} # GE 46202 GE Enbrighten Z-Wave Plus Smart Switch This describes the Z-Wave device *GE 46202*, manufactured by *Jasco Products* with the thing type UID of ```ge_46202_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![GE 46202 product image](https://opensmarthouse.org/zwavedatabase/1109/image/) The GE 46202 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Home automation is even smarter with the GE Enbrighten Z-Wave Plus In-Wall Smart Switch with QuickFit™ and SimpleWire™. When paired with a compatible hub, the hardwired smart switch operates wall, ceiling and accent lighting through individual commands and programmed settings. Wirelessly control and schedule indoor or outdoor fixtures for effortless management of your home. Your automation possibilities are seemingly infinite when connected to hubs from Ring, Wink, SmartThings, HomeSeer, Vera, Nexia and more. ### Inclusion Information 1. Once the controller is ready to include your device, press up and release on the toggle to include it in the network.  2. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance.  ### Exclusion Information Once the controller is ready to exclude your device, press up and release on the toggle to exclude it from the network.  ## Channels The following table summarises the channels available for the GE 46202 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Scene Number | scene_number | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ## Device Configuration The following table provides a summary of the 3 configuration parameters available in the GE 46202. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | LED Mode | LED Indication Configuration | | 4 | Invert Switch | Invert Switch | | 19 | Alternate Exclusion | Set Alternate Exclusion Mode | ### Parameter 3: LED Mode LED Indication Configuration Sets mode for LED inside toggle switch The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | LED ON when switch is OFF | | 1 | LED ON when switch is ON | | 2 | LED always OFF | | 3 | LED Always ON | The manufacturer defined default value is ```2``` (LED always OFF). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Invert Switch Invert Switch If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal Switch Install | | 1 | Inverted Switch Install | The manufacturer defined default value is ```0``` (Normal Switch Install). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 19: Alternate Exclusion Set Alternate Exclusion Mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Press any button on the switch | | 1 | Alternate Exclusion | The manufacturer defined default value is ```0``` (Press any button on the switch). This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The GE 46202 supports 3 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline Association group 1 supports 5 nodes. ### Group 2: Group 2 Basic Set single click Association group 2 supports 5 nodes. ### Group 3: Basic Set double click Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_APPLICATION_STATUS_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [GE 46202 Manual](https://opensmarthouse.org/zwavedatabase/1109/reference/46202-QSG-v1.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1109).