--- layout: documentation title: Da Vinci Switch Default - ZWave --- {% include base.html %} # Da Vinci Switch Default This describes the Z-Wave device *Da Vinci Switch Default*, manufactured by *Avadesign Technology Co.* with the thing type UID of ```avadesign_davincivsw9_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![Da Vinci Switch Default product image](https://opensmarthouse.org/zwavedatabase/911/image/) The Da Vinci Switch Default supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Da Vinci wall controller is a Multi Chanel Z-Wave device that contains up to 6 relays and up to 9 touch buttons that can be set to control either the relays (On/Off switches and shutters) or any other on/off (SWITCH\_BINARY)  , shutter (MULTILEVEL\_SWITCH) Z-Wave device. ### Inclusion Information Press the #1 button 3 times. ### Exclusion Information Press the #1 button 3 times. ## Channels The following table summarises the channels available for the Da Vinci Switch Default -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Blinds control | blinds_control | blinds_control | Blinds | Rollershutter | | Scene Number | scene_number | scene_number | | Number | | Switch 1 | switch_binary1 | switch_binary | Switch | Switch | | Scene Number 1 | scene_number1 | scene_number | | Number | | Switch 2 | switch_binary2 | switch_binary | Switch | Switch | | Scene Number 2 | scene_number2 | scene_number | | Number | | Switch 3 | switch_binary3 | switch_binary | Switch | Switch | | Scene Number 3 | scene_number3 | scene_number | | Number | | Switch 4 | switch_binary4 | switch_binary | Switch | Switch | | Scene Number 4 | scene_number4 | scene_number | | Number | | Switch 5 | switch_binary5 | switch_binary | Switch | Switch | | Scene Number 5 | scene_number5 | scene_number | | Number | | Switch 6 | switch_binary6 | switch_binary | Switch | Switch | | Scene Number 6 | scene_number6 | scene_number | | Number | | Switch 7 | switch_binary7 | switch_binary | Switch | Switch | | Scene Number 7 | scene_number7 | scene_number | | Number | | Switch 8 | switch_binary8 | switch_binary | Switch | Switch | | Scene Number 8 | scene_number8 | scene_number | | Number | | Switch 9 | switch_binary9 | switch_binary | Switch | Switch | | Scene Number 9 | scene_number9 | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Blinds control Provides start / stop control of blinds. The ```blinds_control``` channel is of type ```blinds_control``` and supports the ```Rollershutter``` item and is in the ```Blinds``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 1 Triggers when a scene button is pressed. The ```scene_number1``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 2 Triggers when a scene button is pressed. The ```scene_number2``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 3 Switch the power on and off. The ```switch_binary3``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 3 Triggers when a scene button is pressed. The ```scene_number3``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 4 Switch the power on and off. The ```switch_binary4``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 4 Triggers when a scene button is pressed. The ```scene_number4``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 5 Switch the power on and off. The ```switch_binary5``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 5 Triggers when a scene button is pressed. The ```scene_number5``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 6 Switch the power on and off. The ```switch_binary6``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 6 Triggers when a scene button is pressed. The ```scene_number6``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 7 Switch the power on and off. The ```switch_binary7``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 7 Triggers when a scene button is pressed. The ```scene_number7``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 8 Switch the power on and off. The ```switch_binary8``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 8 Triggers when a scene button is pressed. The ```scene_number8``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 9 Switch the power on and off. The ```switch_binary9``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number 9 Triggers when a scene button is pressed. The ```scene_number9``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ## Device Configuration The following table provides a summary of the 29 configuration parameters available in the Da Vinci Switch Default. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | EP 1 Type | EP 1 Type | | 2 | EP 1 Partner Id | EP 1 Partner Id | | 3 | EP 1 Blind Duration | EP 1 Blind Duration | | 4 | EP 1 Output | EP 1 Output | | 5 | EP 1 Button attribute | EP 1 Button attribute | | 6 | EP 2 Type | EP 2 Type | | 7 | EP 2 Partner Id | EP 2 Partner Id | | 8 | EP 2 Blind Duration | EP 2 Blind Duration | | 11 | EP 3 Type | EP 3 Type | | 12 | EP 3 Partner-Id | EP 3 Partner-Id | | 13 | EP 3 Blind Duration | EP 3 Blind Duration | | 16 | EP 4 Type | EP 4 Type | | 17 | EP 4 Partner-Id | EP 4 Partner-Id | | 18 | EP 4 Blind Duration | EP 4 Blind Duration | | 21 | EP 5 Type | EP 5 Type | | 22 | EP 5 Partner-Id | EP 5 Partner-Id | | 23 | EP 5 Blind Duration | EP 5 Blind Duration | | 26 | EP 6 Type | EP 6 Type | | 27 | EP 6 Partner-Id | EP 6 Partner-Id | | 28 | EP 6 Blind Duration | EP 6 Blind Duration | | 31 | EP 7 Type | EP 7 Type | | 32 | EP 7 Partner-Id | EP 7 Partner-Id | | 33 | EP 7 Blind Duration | EP 7 Blind Duration | | 36 | EP 8 Type | EP 8 Type | | 37 | EP 8 Partner-Id | EP 8 Partner-Id | | 38 | EP 8 Blind Duration | EP 8 Blind Duration | | 41 | EP 9 Type | EP 9 Type | | 42 | EP 9 Partner-Id | EP 9 Partner-Id | | 43 | EP 9 Blind Duration | EP 9 Blind Duration | ### Parameter 1: EP 1 Type EP 1 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 1 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: EP 1 Partner Id EP 1 Partner Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: EP 1 Blind Duration EP 1 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: EP 1 Output EP 1 Output 0 = not used 1 – 6 = Num. of output Values in the range 1 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: EP 1 Button attribute EP 1 Button attribute Bit [0] = LED enable Bit [1] = Sound enable Bit [2] = Dry contact enable Bit [3] = Motor enable Values in the range 0 to 7 may be set. The manufacturer defined default value is ```7```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: EP 2 Type EP 2 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: EP 2 Partner Id EP 2 Partner Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: EP 2 Blind Duration EP 2 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 11: EP 3 Type EP 3 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: EP 3 Partner-Id EP 3 Partner-Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: EP 3 Blind Duration EP 3 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 16: EP 4 Type EP 4 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_16_1``` and is of type ```INTEGER```. ### Parameter 17: EP 4 Partner-Id EP 4 Partner-Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_17_1``` and is of type ```INTEGER```. ### Parameter 18: EP 4 Blind Duration EP 4 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_18_1``` and is of type ```INTEGER```. ### Parameter 21: EP 5 Type EP 5 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_21_1``` and is of type ```INTEGER```. ### Parameter 22: EP 5 Partner-Id EP 5 Partner-Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_22_1``` and is of type ```INTEGER```. ### Parameter 23: EP 5 Blind Duration EP 5 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_23_1``` and is of type ```INTEGER```. ### Parameter 26: EP 6 Type EP 6 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_26_1``` and is of type ```INTEGER```. ### Parameter 27: EP 6 Partner-Id EP 6 Partner-Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_27_1``` and is of type ```INTEGER```. ### Parameter 28: EP 6 Blind Duration EP 6 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_28_1``` and is of type ```INTEGER```. ### Parameter 31: EP 7 Type EP 7 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_31_1``` and is of type ```INTEGER```. ### Parameter 32: EP 7 Partner-Id EP 7 Partner-Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_32_1``` and is of type ```INTEGER```. ### Parameter 33: EP 7 Blind Duration EP 7 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_33_1``` and is of type ```INTEGER```. ### Parameter 36: EP 8 Type EP 8 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_36_1``` and is of type ```INTEGER```. ### Parameter 37: EP 8 Partner-Id EP 8 Partner-Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_37_1``` and is of type ```INTEGER```. ### Parameter 38: EP 8 Blind Duration EP 8 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_38_1``` and is of type ```INTEGER```. ### Parameter 41: EP 9 Type EP 9 Type 1 = switch on/off 2 = blind up 3 = blind down 4 = switch multiway 5 = blind-up multiway 6 = blind-down multiway Values in the range 0 to 6 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_41_1``` and is of type ```INTEGER```. ### Parameter 42: EP 9 Partner-Id EP 9 Partner-Id Values in the range 0 to 9 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_42_1``` and is of type ```INTEGER```. ### Parameter 43: EP 9 Blind Duration EP 9 Blind Duration Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_43_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The Da Vinci Switch Default supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 3 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 4 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 5 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 6 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 7 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 8 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 9 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/911/reference/DA-VINCI-ver-9.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/911).