--- layout: documentation title: DSC25 - ZWave --- {% include base.html %} # DSC25 Smart Energy Illuminator G2 This describes the Z-Wave device *DSC25*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc25_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![DSC25 product image](https://opensmarthouse.org/zwavedatabase/276/image/) The DSC25 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview Plugin dimmer for a lamp ### Inclusion Information 1. Press the Action Button 2. If successfully linked, the LED will no longer blink ### Exclusion Information 1. Press the Action Button 2. If successfully removed, the LED will blink ### Wakeup Information The DSC25 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. ## Channels The following table summarises the channels available for the DSC25 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ## Device Configuration The following table provides a summary of the 1 configuration parameters available in the DSC25. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Configure Blinking LED | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 2: Configure Blinking LED Values in the range 1 to 33000 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSC25 supports 2 association groups. ### Group 1: Hail Command / Basic Report Association group 1 supports 5 nodes. ### Group 2: Commands Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_HAIL_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/276/reference/AeonLabs-DSC25-ZWUS-manual.pdf) * [Engineering Spec](https://opensmarthouse.org/zwavedatabase/276/reference/Smart-Dimmer-G2.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/276).