--- layout: documentation title: TZDW-100 - ZWave --- {% include base.html %} # TZDW-100 Door/window sensor This describes the Z-Wave device *TZDW-100*, manufactured by *[Telldus Technologies AB](http://www.telldus.com/)* with the thing type UID of ```telldus_tzdw100_00_000```. The device is in the category of *Sensor*, defining Device used to measure something. ![TZDW-100 product image](https://opensmarthouse.org/zwavedatabase/312/image/) The TZDW-100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The TZDW-100 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview This magnet sensor contains the latest Z-Wave technology with the ability to remotely control other Z-Wave units available in your network. The fact that it is battery operated and so small you can virtually place it anywhere you want – on doors, windows or drawers, without the need of wiring. Screw or tape up the holder and then click the sensor in place. Done! The sensor is designed to be seen as little as possible and we have made it significantly smaller than other sensors. It consists of two parts that will merge into a stylish unit when the sensor is closed ### Inclusion Information Press the button on the device three times fast. ### Exclusion Information Press the button on the device three times fast. ### Wakeup Information The TZDW-100 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. Press the button on the sensor one time short to wake up the device.  ## Channels The following table summarises the channels available for the TZDW-100 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Door Sensor | sensor_door | sensor_door | Door | Contact | | Alarm | alarm_general | alarm_general | Alarm | Switch | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Door Sensor Indicates if the door/window is open or closed. The ```sensor_door``` channel is of type ```sensor_door``` and supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Contact``` item type -: | Value | Label | |-------|-----------| | OPEN | Open | | CLOSED | Closed | ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The following table provides a summary of the 8 configuration parameters available in the TZDW-100. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Group 2 Command Type | Select what type of command to be sent to nodes in association group 2 | | 2 | Group 2 Value | Select what value that should be sent to association group 2 | | 3 | Group 2 Signal Type | Type of commands to association group 2 | | 4 | Group 3 Command Type | Select what type of command to be sent to nodes in association group 3 | | 5 | Group 3 Value | Select what value that should be sent to association group 3 | | 6 | Group 3 Signal Type | Type of commands to association group 3 | | 7 | LED-Indicator | LED-Indicator | | 8 | Lifeline command Type | Select the type of command to be sent in the Lifeline | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | ### Parameter 1: Group 2 Command Type Select what type of command to be sent to nodes in association group 2 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Basic | | 1 | Switch Binary | | 2 | Switch All | | 3 | Switch Multilevel | The manufacturer defined default value is ```0``` (Basic). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Group 2 Value Select what value that should be sent to association group 2 The following option values may be configured, in addition to values in the range 0 to 63 -: | Value | Description | |--------|-------------| | 255 | Last value | The manufacturer defined default value is ```255``` (Last value). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Group 2 Signal Type Type of commands to association group 2 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal | | 1 | Inverted | The manufacturer defined default value is ```0``` (Normal). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Group 3 Command Type Select what type of command to be sent to nodes in association group 3 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Basic | | 1 | Switch Binary | | 2 | Switch All | | 3 | Switch Multilevel | The manufacturer defined default value is ```0``` (Basic). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Group 3 Value Select what value that should be sent to association group 3 The following option values may be configured, in addition to values in the range 0 to 63 -: | Value | Description | |--------|-------------| | 255 | Last value | The manufacturer defined default value is ```255``` (Last value). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Group 3 Signal Type Type of commands to association group 3 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal | | 1 | Inverted | The manufacturer defined default value is ```0``` (Normal). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: LED-Indicator LED-Indicator The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Off | | 1 | On | The manufacturer defined default value is ```1``` (On). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Lifeline command Type Select the type of command to be sent in the Lifeline The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Notification | | 1 | Sensor binary | The manufacturer defined default value is ```0``` (Notification). This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The TZDW-100 supports 3 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline - Sensor status Association group 1 supports 1 node. ### Group 2: Group 2 Sensor open and closed Association group 2 supports 10 nodes. ### Group 3: Group 3 Sensor Open Only Association group 3 supports 10 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_BINARY_V2| Linked to BASIC| | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V4| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2| | ### Documentation Links * [Technical Manual](https://opensmarthouse.org/zwavedatabase/312/reference/TZDW-100-technical-manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/312).