--- layout: documentation title: ZV9001K12-DIM-Z5 - ZWave --- {% include base.html %} # ZV9001K12-DIM-Z5 Dim Remote Control This describes the Z-Wave device * ZV9001K12-DIM-Z5*, manufactured by *[Sunricher](www.sunricher.com)* with the thing type UID of ```sunricher_zv9001k12dimz5_00_000```. The device is in the category of *Remote Control*, defining Any portable or hand-held device that controls the status of something, e.g. remote control, keyfob etc.. ![ ZV9001K12-DIM-Z5 product image](https://opensmarthouse.org/zwavedatabase/1296/image/) The ZV9001K12-DIM-Z5 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The ZV9001K12-DIM-Z5 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. ### Inclusion Information Press and hold down both buttons All On and All Off for over 3 seconds, LED indicator turns on, the remote control will be set to inclusion mode, and waiting to be included, after 10s LED indicator blinks 6 times quickly to indicate successful inclusion. The remote control is a sleepy device, after inclusion it will not enter into sleepy mode immediately, and will continue activation status for 30s and wait data interaction from the gateway, the LED indicator will stay solid on, please be patient to wait LED indicator to turn off. ### Exclusion Information Press and hold down both buttons All On and All Off for over 3 seconds, LED indicator turns on, the remote control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 times quickly to indicate successful exclusion. ### Wakeup Information The ZV9001K12-DIM-Z5 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. Press and hold down both buttons All On and All Off for over 3 seconds ### General Usage Information ## Channels The following table summarises the channels available for the ZV9001K12-DIM-Z5 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Scene Number | scene_number | scene_number | | Number | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ZV9001K12-DIM-Z5 supports 6 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ### Group 2: Launch 1 Association group 2 supports 5 nodes. ### Group 3: Launch 2 Association group 3 supports 5 nodes. ### Group 4: Launch 3 Association group 4 supports 5 nodes. ### Group 5: Launch 4 Association group 5 supports 5 nodes. ### Group 6: Launch 5 Association group 6 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_TRANSPORT_SERVICE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_SUPERVISION_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_SECURITY_V1| | | COMMAND_CLASS_SECURITY_2_V1| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1296/reference/SR-ZV9001K12-DIM-Z5 V2 Instruction.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1296).