--- layout: documentation title: SM-PZ701U - ZWave --- {% include base.html %} # SM-PZ701U Z-Wave power plug This describes the Z-Wave device *SM-PZ701U*, manufactured by *Sigma Designs (Former Zensys)* with the thing type UID of ```sigma_smpz701u_00_000```. ![SM-PZ701U product image](https://opensmarthouse.org/zwavedatabase/602/image/) The SM-PZ701U supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](https://opensmarthouse.org/zwavedatabase/602) to improve the documentation. ## Channels The following table summarises the channels available for the SM-PZ701U -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Switch 1 | switch_binary1 | switch_binary | Switch | Switch | | Switch 2 | switch_binary2 | switch_binary | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The SM-PZ701U supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/602).