--- layout: documentation title: POPE700052 - ZWave --- {% include base.html %} # POPE700052 Water Leakage Sensor This describes the Z-Wave device *POPE700052*, manufactured by *Popp & Co* with the thing type UID of ```popp_pope700052_00_000```. The device is in the category of *Sensor*, defining Device used to measure something. ![POPE700052 product image](https://opensmarthouse.org/zwavedatabase/748/image/) The POPE700052 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The POPE700052 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview The Flood Sensor is a universal Z-Wave compatible flood sensor indicating water leakage in Smart Homes. In case of a detected incident the device will send an alarm message to a central controller and can in parallel directly control a group of devices, e.g. to shut off water supply. On the device it self the water event will be indicated using a red LED and a buzzer. This behavior can be configured. The device can be mounted on a wall for easy maintenance and the water is detected using a cabled detector head. The cable is 90 cm long. The device can also be used without the mounting base and will then flow on the water surface ### Inclusion Information  A single click on the Z-Wave button inside the device includes and excludes the device. ### Exclusion Information  A single click on the Z-Wave button inside the device includes and excludes the device. ### Wakeup Information The POPE700052 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. To wakeup the device please perform the following action: Double click the internal Button. The red LED will light up to confirm the action. ## Channels The following table summarises the channels available for the POPE700052 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Binary Sensor | sensor_binary | sensor_binary | | Switch | | Alarm (flood) | alarm_flood | alarm_flood | Water | Switch | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Binary Sensor Indicates if a sensor has triggered. The ```sensor_binary``` channel is of type ```sensor_binary``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Triggered | | OFF | Untriggered | ### Alarm (flood) Indicates if the flood alarm is triggered. The ```alarm_flood``` channel is of type ```alarm_flood``` and supports the ```Switch``` item and is in the ```Water``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The following table provides a summary of the 3 configuration parameters available in the POPE700052. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Flood Alarm Basic On Value | Flood detected | | 2 | Flood Alarm Basic Off Value | No Flood detected | | 3 | Enable Buzzer Sound on Alarm | Buzzer enabled during flood detection | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | ### Parameter 1: Flood Alarm Basic On Value Flood detected Values in the range 0 to 255 may be set. The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. This is a read only parameter. ### Parameter 2: Flood Alarm Basic Off Value No Flood detected Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. This is a read only parameter. ### Parameter 3: Enable Buzzer Sound on Alarm Buzzer enabled during flood detection Values in the range 0 to 1 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The POPE700052 supports 2 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ### Group 2: Water is detected Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_BINARY_V2| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V5| Linked to BASIC| | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [Popp Water Leakage Sensor POPE700052](https://opensmarthouse.org/zwavedatabase/748/reference/POPE700052.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/748).