--- layout: documentation title: PAN06 - ZWave --- {% include base.html %} # PAN06 In Wall Dual Relay (1 Way) Switch Module 2 x 1.5kW This describes the Z-Wave device *PAN06*, manufactured by *[Philio Technology Corp](http://www.philio-tech.com/)* with the thing type UID of ```philio_pan06_01_008```. This version of the device is limited to firmware versions above 1.8 The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![PAN06 product image](https://opensmarthouse.org/zwavedatabase/858/image/) The PAN06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The PAN06 allows controlling two independent loads both wirelessly via Z-Wave and locally utilizing a traditional wall switch. Thanks to its calibration technology the device cannot only be used to switch resistive devices but also works perfectly with many kind of reactive or resistive loads such as fluorescent lights or LEDs. The device is placed in a wall box right behind the normal switch. The switch is not longer directly connected to the load but acts as input device for the insert that is controlling the load. This device is designed for a 3 wire system and needs a neutral wire in the wall box. ### Inclusion Information 1. Have Z-Wave Controller entered inclusion mode. 2. Pressing Include button of PAN06 three times within 2 seconds will enter inclusion mode ### Exclusion Information 1. Have Z-Wave Controller entered exclusion mode. 2. Pressing Include button of PAN06 three times within 2 seconds will enter exclusion mode ## Channels The following table summarises the channels available for the PAN06 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Scene Number | scene_number | scene_number | | Number | | Alarm | alarm_general | alarm_general | Alarm | Switch | | Switch 1 | switch_binary1 | switch_binary | Switch | Switch | | Switch 2 | switch_binary2 | switch_binary | Switch | Switch | | Switch 3 | switch_binary3 | switch_binary | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 3 Switch the power on and off. The ```switch_binary3``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 6 configuration parameters available in the PAN06. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Selected endpoint | Send Basic Command Class | | 2 | Switch mode | Change the external switch mode | | 3 | Restore Switch State Mode | Switch state after repowering | | 4 | Auto OFF Timer | | | 5 | RF OFF command | RF OFF command mode | | 6 | Existence of endpoint 3 | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Selected endpoint Send Basic Command Class If Controller not using Multi_Channel command class to access the endpoint of PAN06, you may configure the endpoint value to react the Basic Command Class The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Relay 1 | | 2 | Relay 2 | | 3 | Relay 1+2 | The manufacturer defined default value is ```3``` (Relay 1+2). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Switch mode Change the external switch mode The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Edge mode | | 2 | Pulse mode | | 3 | Edge-Toggle mode | The manufacturer defined default value is ```1``` (Edge mode). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Restore Switch State Mode Switch state after repowering 0 : Switch off 1 : Last switch state 2 : Switch on Whenever the AC power return from lost, PAN06 will restore the switch state which could be SWITCH OFF、 LAST SWITCH STATE、 SWITCH ON. The default setting is LAST SWITCH STATE The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch OFF | | 1 | Last Switch state | | 2 | Switch ON | The manufacturer defined default value is ```1``` (Last Switch state). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Auto OFF Timer Values in the range 0 to 32767 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 5: RF OFF command RF OFF command mode Whenever a switch off command, BASIC\_SET 、BINARY\_SWITCH_SET 、 SWITCH\_ALL\_OFF, is received, it could be interpreted as 4 variety of commands. 3-5-1 Switch Off:It switches to OFF state. The default setting is Switch Off. 3-5-2 Ignore:The switch off command will be ignored. 3-5-3 Switch Toggle:It switches to the inverse of current state. 3-5-4 Switch On:It switches to ON state. 0 : Switch off 1 : Ignore 2 : Switch toggle 3 : Switch on The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch OFF | | 1 | Ignore | | 2 | Switch toggle | | 3 | Switch on | The manufacturer defined default value is ```0``` (Switch OFF). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Existence of endpoint 3 The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Endpoint 3 exists | | 2 | No endpoint 3 | The manufacturer defined default value is ```1``` (Endpoint 3 exists). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The PAN06 supports 3 association groups. ### Group 1: Relay 1 + 2 Association group 1 supports 1 node. ### Group 2: Relay 1 Association group 2 supports 1 node. ### Group 3: Relay 2 Association group 3 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_PROTECTION_V2| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| #### Endpoint 3 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| ### Documentation Links * [PAN06-1B Manual](https://opensmarthouse.org/zwavedatabase/858/reference/C50101008V01-PAN06-1-2-3B-manual-20150831.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/858).