--- layout: documentation title: 78008 - ZWave --- {% include base.html %} # 78008 Door/Window Sensor with Magnet This describes the Z-Wave device *78008*, manufactured by *Good Way Technology Co., Ltd* with the thing type UID of ```goodway_78008_00_000```. The device is in the category of *Door*, defining Door sensors. ![78008 product image](https://opensmarthouse.org/zwavedatabase/827/image/) The 78008 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Z-Wave Door/Window sensor with magnet can include 2 extern sensors ### Inclusion Information 1. Install the battery and close the lid 2. Set your gateway/controller to the inclusion mode 3. Push the TMP button on the bottom side 3 times in 2 seconds 4. if the inclusion was succesfully the software will show it ### Exclusion Information 1. Set your gateway/controller to the exclusion mode 2. Push the TMP button on the bottom side 3 times in 2 seconds 3. The device is logged off ## Channels The following table summarises the channels available for the 78008 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Binary Sensor | sensor_binary | sensor_binary | | Switch | | Alarm | alarm_general | alarm_general | Alarm | Switch | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Binary Sensor Indicates if a sensor has triggered. The ```sensor_binary``` channel is of type ```sensor_binary``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Triggered | | OFF | Untriggered | ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The following table provides a summary of the 10 configuration parameters available in the 78008. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Basic set level for nodes of group2 | 255: Binary switch ON, 1-99: Dimmer level | | 2 | Basic set OFF delay time for nodes of group2 | 0: Disable, 0-127 Second | | 3 | Delay time to enter standby mode | After force to wake up, delay time to enter standby mode again | | 4 | Delay time to enter standby after wake up | Delay time to enter standby after wake up | | 5 | Set waiting exclusion time | Set waiting exclusion time | | 6 | Activate/Deactivate WUT standby mode | 0: Always wake up, 1: Enter standby mode | | 7 | Activate/Deactivate Tamper alarm mode | 0: Disable, 1: Enable | | 8 | Tamper alarm continuously send | In tamper alarm mode, delay time for continuously send Sensor\_Binary\_report | | 9 | Interval time for sending battery report | The interval time of sending battery report | | 10 | set the configuration of 2 external sensors | BIT0: sensor1 (S1), BIT1: sensor2 (S2) | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | ### Parameter 1: Basic set level for nodes of group2 255: Binary switch ON, 1-99: Dimmer level 255: Binary switch ON 1-99: Dimmer level  Values in the range 0 to 255 may be set. The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Basic set OFF delay time for nodes of group2 0: Disable, 0-127 Second 0: Disable 0-127 Seconds Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Delay time to enter standby mode After force to wake up, delay time to enter standby mode again After force to wake up, delay time to enter standby mode again Values in the range 1 to 255 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Delay time to enter standby after wake up Delay time to enter standby after wake up In standby mode, after wake up, delay time for standby again Values in the range 1 to 255 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Set waiting exclusion time Set waiting exclusion time Values in the range 1 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Activate/Deactivate WUT standby mode 0: Always wake up, 1: Enter standby mode 0: Always wake up 1: Enter standby mode (Auto-reboot after setting completed) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Alwas wake up | | 1 | Enter standby mode | The manufacturer defined default value is ```1``` (Enter standby mode). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: Activate/Deactivate Tamper alarm mode 0: Disable, 1: Enable 0: Disable tamper alarm mode 1: Enable tamper alarm mode (Auto reboot after setting completed) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Tamper alarm continuously send In tamper alarm mode, delay time for continuously send Sensor\_Binary\_report In tamper alarm mode, delay time for continuously send Sensor\_Binary\_report Values in the range 3 to 30 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Interval time for sending battery report The interval time of sending battery report The interval time of sending battery report when the battery runs out of electricity The following option values may be configured -: | Value | Description | |--------|-------------| | 3 | Report every 3 minutes | | 5 | Report every 5 minutes | | 10 | Report every 10 minutes | The manufacturer defined default value is ```3``` (Report every 3 minutes). This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: set the configuration of 2 external sensors BIT0: sensor1 (S1), BIT1: sensor2 (S2) BIT0: sensor1 (S1) BIT1: sensor2 (S2) 0 (00b): S2 NO, S1 NO 1 (01b): S2 NO, S1 NC 2 (10b): S2 NC, S1 NO 3 (11b): S2 NC, S1 NC Values in the range 0 to 3 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 78008 supports 2 association groups. ### Group 1: Reports All autoreports send to Group 1 Association group 1 supports 1 node. ### Group 2: Sensor ON/OFF status (Basic_set command) Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_BINARY_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Device Manual](https://opensmarthouse.org/zwavedatabase/827/reference/Manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/827).