--- layout: documentation title: FGD211 - ZWave --- {% include base.html %} # FGD211 Universal Dimmer 500W This describes the Z-Wave device *FGD211*, manufactured by *[Fibargroup](http://www.fibaro.com/)* with the thing type UID of ```fibaro_fgd211_02_001```. This version of the device is limited to firmware versions above 2.1 The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![FGD211 product image](https://opensmarthouse.org/zwavedatabase/119/image/) The FGD211 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Remotely controlled Dimmer is designed to operate with or without neutral lead. It may be used as a switch in systems without neutral lead. ### Inclusion Information The Dimmer enters the mode of inclusion after quick pressing three times the push-button connected to S1 terminal or push-button B located inside the housing. ### Exclusion Information The Dimmer enters the mode of exclusion after quick pressing three times the push-button connected to S1 terminal or push-button B located inside the housing. ## Channels The following table summarises the channels available for the FGD211 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | scene_number | | Number | | Updating the dimming level without switch | config_decimal | config_decimal | | Number | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. ### Updating the dimming level without switch Generic class for configuration parameter. The ```config_decimal``` channel is of type ```config_decimal``` and supports the ```Number``` item. ## Device Configuration The following table provides a summary of the 20 configuration parameters available in the FGD211. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Enable/Disable ALL ON/OFF | Activate/Deactive ALL ON/OFF | | 6 | Separation of association sending (key 1) | Activate/Deactivate association sending for group 1 - Also see param #16 | | 7 | Control key #2 behaviour | Checking the device status before sending a control frame from the key no. 2. | | 8 | Dimming step at automatic control | | | 9 | Time of MANUALLY moving between dimming values | Options for changing parameter 1-255 (10ms - 2,5s) | | 10 | Time of AUTOMATIC moving between dimming values | Time of Automatic moving the Dimmer between the extreme dimming values | | 11 | Dimming step at manual control | Options for changing parameter 1-99 | | 12 | Maximum dimmer level control | Options for changing parameter 2-99 | | 13 | Minimum dimmer level control | Options for changing parameter 1-98 | | 14 | Inputs Button/Switch configuration | Binary inputs type configuration | | 15 | Parm 15 | Double-click set lighting at 100% | | 16 | Saving state before power failure | Saving state before power failure | | 17 | 3-way switch | 3-way switch function | | 18 | Synchronizing light level for associated devices | The dimmer communicate the level to the associated devices. (default value 0) | | 19 | Change [On-Off] bi-stable keys | Assigns bistable key status to the device status. | | 20 | Minimum level of the Dimmer | Enable decreasing the minimum level of the Dimmer | | 30 | Relay 1: Response to General Alarm | Resonse to alarm of any type | | 39 | ALARM FLASHING alarm time | Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame | | 40 | Updating the dimming level without switch. | Available settings: from 1 to 99. | | 41 | Scene activation functionality | Sending commands with command class scene activation | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | ALL ON disabled / ALL OFF disabled | | 1 | ALL ON disabled / ALL OFF active | | 2 | ALL ON active / ALL OFF disabled | | 255 | ALL ON active / ALL OFF active | The manufacturer defined default value is ```255``` (ALL ON active / ALL OFF active). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 6: Separation of association sending (key 1) Activate/Deactivate association sending for group 1 - Also see param #16 Sending commands to control devices assigned to 1-st association group (key no. 1). NOTE: Parameter 15 value must be set to 1 to work properly. This activates the double-click functionality - dimmer/roller shutter control. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Map status to all devices in group 1 | | 1 | Map OFF status to devices in group 1 - last state | | 2 | Map OFF status to devices in group 1 - 100% state | The manufacturer defined default value is ```0``` (Map status to all devices in group 1). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: Control key #2 behaviour Checking the device status before sending a control frame from the key no. 2. Info: Key no. 2 is not represented by any physical device expect of devices on association list. This functionality prevents of lack of reaction on pressing key no. 2 through polling devices from list one by one and checking thier actual states. It is not possible to check the device status before sending a control frame from the key no. 2 if roller blind switch is chosen in parameter 14 (value 2) If devices state is checked before sending asociation then parameter 19 should be set to value 0. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Device status is not checked | | 1 | Device status is checked | The manufacturer defined default value is ```1``` (Device status is checked). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Dimming step at automatic control Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Time of MANUALLY moving between dimming values Options for changing parameter 1-255 (10ms - 2,5s) Values in the range 1 to 255 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Time of AUTOMATIC moving between dimming values Time of Automatic moving the Dimmer between the extreme dimming values Options for changing parameter 0-255 (0ms – 2.5s) 0 - this value disables the smooth change in light intensity NOTE value 0 is required for inductive and capacitive devices unsuitable for dimming, (e.g. fluorescent lamps , motors etc.) Values in the range 0 to 255 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Dimming step at manual control Options for changing parameter 1-99 Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Maximum dimmer level control Options for changing parameter 2-99 Values in the range 2 to 99 may be set. The manufacturer defined default value is ```99```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Minimum dimmer level control Options for changing parameter 1-98 Values in the range 1 to 98 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Inputs Button/Switch configuration Binary inputs type configuration The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Mono-stable input (button) | | 1 | Bi-stable input (switch) | | 2 | Roller blind switch (UP / DOWN) | The manufacturer defined default value is ```0``` (Mono-stable input (button)). This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: Parm 15 Double-click set lighting at 100% The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable double click | | 1 | Enable double click | The manufacturer defined default value is ```1``` (Enable double click). This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 16: Saving state before power failure Saving state before power failure The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | State NOT saved at power failure | | 1 | State saved at power failure. | The manufacturer defined default value is ```1``` (State saved at power failure.). This parameter has the configuration ID ```config_16_1``` and is of type ```INTEGER```. ### Parameter 17: 3-way switch 3-way switch function The function of 3 - way switch, provides the option to double key no. 1. The Dimmer may control two toggle push-buttons or an infinite number of momentary push-buttons.   The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_17_1``` and is of type ```INTEGER```. ### Parameter 18: Synchronizing light level for associated devices The dimmer communicate the level to the associated devices. (default value 0) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_18_1``` and is of type ```INTEGER```. ### Parameter 19: Change [On-Off] bi-stable keys Assigns bistable key status to the device status. Info: Remote control from Fibaro System Is Still Possible. This function is useful When you want display status of external devices, e.g. Motion Sensor, in Fibaro System.   The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Device changes status on key status change | | 1 | Device status depends on key status. | The manufacturer defined default value is ```0``` (Device changes status on key status change). This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ### Parameter 20: Minimum level of the Dimmer Enable decreasing the minimum level of the Dimmer This function will enable decreasing the minimum level of the Dimmer by extending the control impulse. [100 - 170]       By changing the minimem level, the user may completely dim LED bulbs. Not all LED bulbs available on the market have the dimmm Values in the range 100 to 170 may be set. The manufacturer defined default value is ```110```. This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 30: Relay 1: Response to General Alarm Resonse to alarm of any type Alarm of any type (general alarm, water flooding alarm, smoke alarm: CO, CO2, temperature alarm).   The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deactivation | | 1 | Alarm Dimmer ON | | 2 | Alarm Dimmer OFF | | 3 | Alarm Flashing | The manufacturer defined default value is ```3``` (Alarm Flashing). This parameter has the configuration ID ```config_30_1``` and is of type ```INTEGER```. ### Parameter 39: ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_39_2``` and is of type ```INTEGER```. ### Parameter 40: Updating the dimming level without switch. Available settings: from 1 to 99. Parameter’s value changes depending on the dimming level.   Values in the range 1 to 99 may be set. The manufacturer defined default value is ```99```. This parameter has the configuration ID ```config_40_1``` and is of type ```INTEGER```. ### Parameter 41: Scene activation functionality Sending commands with command class scene activation The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. Controllers such as Home Center 2 are able to interpret such commands and based on these commands they activate scenes, to which specific scene IDs have been assigned. The user may expand the functionality of the button connected to inputs S1 and S2 by distinguishing the actions of keys connected to those inputs. For example: double click would activate the scene "goodnight" and triple click would activate the scene "morning" The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Scene functionality deactivated | | 1 | Scene functionality activated | The manufacturer defined default value is ```0``` (Scene functionality deactivated). This parameter has the configuration ID ```config_41_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The FGD211 supports 3 association groups. ### Group 1: Switch 1 Association group 1 supports 5 nodes. ### Group 2: Switch 2 Association group 2 supports 5 nodes. ### Group 3: Controller Updates Association group 3 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/119/reference/fibaro---fgd-211---manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/119).