--- layout: documentation title: powerSwitch - ZWave --- {% include base.html %} # powerSwitch Power Switch EU This describes the Z-Wave device *powerSwitch*, manufactured by *[BeNext](http://www.benext.eu/)* with the thing type UID of ```benext_powerswitch_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![powerSwitch product image](https://opensmarthouse.org/zwavedatabase/224/image/) The powerSwitch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Basic operations * The Power Switch can be remotely controlled. * The Power Switch can be controlled by the push button on the front of the device. * The Power Switch’s indicator light can indicate the status of the switch (ON or OFF). How it operates Control and monitor your lightning or any other appliance. Easy plug and play.  ### Inclusion Information Press and hold the push button until the indicator light is blinking than release the button to start the inclusion or exclusion process. ### Exclusion Information Press and hold the push button until the indicator light is blinking than release the button to start the inclusion or exclusion process. ## Channels The following table summarises the channels available for the powerSwitch -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 4 configuration parameters available in the powerSwitch. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Set to Default | Set all configuration values to default values (factory settings) | | 4 | Start up with last known socket status | state in what the switch is when power is supplied | | 9 | Relay delay time | Relay delay time | | 10 | Led indicator | Show the led compared to the relay state | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Set to Default Set all configuration values to default values (factory settings) All values (0x00 – 0xFF) except for 0x55 can be used to default all the configuration params . Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 4: Start up with last known socket status state in what the switch is when power is supplied If 0x01–0xFF: When power applied socket is the state before power was disconnected Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 9: Relay delay time Relay delay time When the relay is switched it can't be switched again until the configured time has passed Value * 10 milliseconds Values in the range 0 to 255 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Led indicator Show the led compared to the relay state If value is 0: the indicator led is never switched on If value is 1: the indicator led is switched on when relay is switched on If value is 2: the indicator led is switched on when relay is switched off Values in the range 0 to 2 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The powerSwitch supports 1 association group. ### Group 1: Group 1 Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_PROTECTION_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/224/reference/powerswitch.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/224).