--- layout: documentation title: DSC13 - ZWave --- {% include base.html %} # DSC13 Micro Smart Energy Illuminator This describes the Z-Wave device *DSC13*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc13_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![DSC13 product image](https://opensmarthouse.org/zwavedatabase/287/image/) The DSC13 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Aeon Labs Micro SEI is a scene multilevel switch device based on Zwave enhanced slave library V4.54. ### Inclusion Information Click the button once. ### Exclusion Information Click the button once. ## Channels The following table summarises the channels available for the DSC13 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Sensor (power) | sensor_power | sensor_power | Energy | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Sensor (power) Indicates the energy consumption (kWh). The ```sensor_power``` channel is of type ```sensor_power``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 12 configuration parameters available in the DSC13. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Type of Sensor Report | Defines the value type to be sent as Sensor Report. | | 2 | Blinking Behavior | See overview | | 80 | Notification on Status Change | Type of report to send when the device status changes | | 90 | Disable Minimum Change report | | | 91 | Minimum Change to send Report (Watt) | The minimum change in Wattage for a Report to be sent | | 92 | Minimum Change to send Report (%) | The minimum change in Wattage Percent for a report to be sent | | 101 | Reports to send to Group 1 | See overview | | 102 | Reports to send to Group 2 | See overview | | 103 | Reports to send to Group 3 | See overview | | 111 | Interval to send out reports of group 1 | Time interval to send report to Group 1 | | 112 | Interval to send out reports of group 2 | Time interval to send report to Group 2 | | 113 | Interval to send out reports of group 3 | Time interval to send report to Group 3 | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Type of Sensor Report Defines the value type to be sent as Sensor Report. The following option values may be configured, in addition to values in the range 0 to 1 -: | Value | Description | |--------|-------------| | 0 | Power | | 1 | Voltage | The manufacturer defined default value is ```0``` (Power). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Blinking Behavior See overview The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 80: Notification on Status Change Type of report to send when the device status changes The following option values may be configured, in addition to values in the range 0 to 2 -: | Value | Description | |--------|-------------| | 0 | Nothing | | 1 | Hail | | 2 | Basic CC Report | The manufacturer defined default value is ```0``` (Nothing). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 90: Disable Minimum Change report The following option values may be configured, in addition to values in the range 0 to 1 -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Minimum Change to send Report (Watt) The minimum change in Wattage for a Report to be sent Values in the range 0 to 32000 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Minimum Change to send Report (%) The minimum change in Wattage Percent for a report to be sent Values in the range 0 to 100 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 101: Reports to send to Group 1 See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Reports to send to Group 2 See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Reports to send to Group 3 See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 111: Interval to send out reports of group 1 Time interval to send report to Group 1 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Interval to send out reports of group 2 Time interval to send report to Group 2 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Interval to send out reports of group 3 Time interval to send report to Group 3 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSC13 supports 3 association groups. ### Group 1: Group 1 Status Reports Association group 1 supports 5 nodes. ### Group 2: Group 2 Association group 2 supports 5 nodes. ### Group 3: Group 3 Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V3| | | COMMAND_CLASS_METER_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Spec Sheet](https://opensmarthouse.org/zwavedatabase/287/reference/Micro-Smart-Energy-Illuminator.pdf) * [Spec Sheet](https://opensmarthouse.org/zwavedatabase/287/reference/Micro-Smart-Energy-Illuminator.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/287).