--- layout: documentation title: DSC06 - ZWave --- {% include base.html %} # DSC06 Smart Energy Switch This describes the Z-Wave device *DSC06*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc06_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![DSC06 product image](https://opensmarthouse.org/zwavedatabase/75/image/) The DSC06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Aeon Labs Smart Energy Switch is a Z-Wave appliance switch which can report wattage energy usage or kWh energy usage to a Z-Wave gateway. It can also be controlled by other Z-Wave devices to turn on/off to save electricity when appropriate. ### Inclusion Information 1. Plug the Smart Energy Switch into an outlet 2. Put the controller in inclusion mode 3. Press the button located between the LED If the Aeon Labs Smart Energy Switch was not successfully included into any Z-Wave network, the LED will be blinking. If the Aeon Labs Smart Energy Switch was successfully included to a Z-Wave network, the LED will either be on or off (depending on if the switch is on or off).  ### Exclusion Information 1. Put the controller in exclusion mode 2. Press the button located between the LED If the Aeon Labs Smart Energy Switch was removed from the Z-Wave network, the LED will be blinking. If the Aeon Labs Smart Energy Switch was not successfully removed from the Z-Wave network, the LED will either be on or off (depending on if the switch is on or off).  ## Channels The following table summarises the channels available for the DSC06 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Sensor (power) | sensor_power | sensor_power | Energy | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Sensor (power) Indicates the energy consumption (kWh). The ```sensor_power``` channel is of type ```sensor_power``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 15 configuration parameters available in the DSC06. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Multilevel Sensor Report Content | | | 80 | Automatic Notifications | Enable or disable automatic notifications | | 90 | Enable/disable Parameter 91 and 92 | Enables/disables parameter 91 and 92 below | | 91 | Minimum change in wattage | Minimum change in wattage to trigger event | | 92 | Minimum change in wattage % | Minimum change in wattage % to trigger event | | 100 | Set 101 to 103 to default values | | | 101 | Group 1 report | | | 102 | Group 2 report | | | 103 | Group 3 report | | | 110 | Set 111 to 113 to default values | | | 111 | Interval Group 1 | The time interval (in seconds) for sending report to Group 1 | | 112 | Interval Group 2 | The time interval (in seconds) for sending report to Group 2 | | 113 | Interval Group 3 | The time interval (in seconds) for sending report to Group 3 | | 254 | Device Tag | | | 255 | Device Reset | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Multilevel Sensor Report Content The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Power | | 1 | Voltage | The manufacturer defined default value is ```0``` (Power). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 80: Automatic Notifications Enable or disable automatic notifications Enables automatic notifications to associated devices whenever there is a state change (0=nothing, 1=hail CC, 2=basic CC report) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Nothing | | 1 | Hail | | 2 | Basic CC Report | The manufacturer defined default value is ```0``` (Nothing). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 90: Enable/disable Parameter 91 and 92 Enables/disables parameter 91 and 92 below The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Minimum change in wattage Minimum change in wattage to trigger event The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Minimum change in wattage % Minimum change in wattage % to trigger event The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 100: Set 101 to 103 to default values The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No change | | 1 | Reset | The manufacturer defined default value is ```0``` (No change). This parameter has the configuration ID ```config_100_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 101: Group 1 report The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | None | | 2 | Multisensor Report | | 4 | Meter Report (Watts) | | 8 | Meter Report (kWh) | | 12 | Meter Report Watts and kWh | The manufacturer defined default value is ```8``` (Meter Report (kWh)). This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Group 2 report The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | None | | 2 | Multisensor Report | | 4 | Meter Report (Watts) | | 8 | Meter Report (kWh) | | 12 | Meter Report Watts and kWh | The manufacturer defined default value is ```0``` (None). This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Group 3 report The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | None | | 2 | Multisensor Report | | 4 | Meter Report (Watts) | | 8 | Meter Report (kWh) | | 12 | Meter Report Watts and kWh | The manufacturer defined default value is ```0``` (None). This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 110: Set 111 to 113 to default values The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No change | | 1 | Reset | The manufacturer defined default value is ```0``` (No change). This parameter has the configuration ID ```config_110_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 111: Interval Group 1 The time interval (in seconds) for sending report to Group 1 Values in the range 1 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Interval Group 2 The time interval (in seconds) for sending report to Group 2 Values in the range 1 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Interval Group 3 The time interval (in seconds) for sending report to Group 3 Values in the range 1 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Parameter 254: Device Tag Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_254_2``` and is of type ```INTEGER```. ### Parameter 255: Device Reset The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No change | | 1 | Reset | The manufacturer defined default value is ```0``` (No change). This parameter has the configuration ID ```config_255_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSC06 supports 1 association group. ### Group 1: Status Reports Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V3| | | COMMAND_CLASS_METER_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/75/reference/Engineering-Spec---Aeon-Labs-Smart-Energy-Switch-v1.pdf) * [Manual](https://opensmarthouse.org/zwavedatabase/75/reference/AEDSC06106ZWUS-Manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/75).