--- layout: documentation title: PAN08 - ZWave --- {% include base.html %} # PAN08 roller shutter This describes the Z-Wave device *PAN08*, manufactured by *[Zipato](http://www.zipato.com/)* with the thing type UID of ```zipato_pan08_00_000```. The device is in the category of *Blinds*, defining Roller shutters, window blinds, etc.. ![PAN08 product image](https://www.cd-jackson.com/zwave_device_uploads/924/924_default.jpg) The PAN08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Roller shutter micromodule ### Inclusion Information Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. Pressing Include button three times within 2 seconds will enter inclusion mode.  ### Exclusion Information Put the Z-Wave Controller in exclusion mode. Pressing Include button three times within 2 seconds will enter exclusion mode. Node ID has been excluded. ## Channels The following table summarises the channels available for the PAN08 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Blinds Control | blinds_control | Blinds | Rollershutter | | Scene Number | scene_number | | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (power factor) | meter_powerfactor | Energy | Number | | Alarm | alarm_general | Door | Switch | ### Blinds Control Provides start / stop control of blinds. The ```blinds_control``` channel supports the ```Rollershutter``` item and is in the ```Blinds``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (power factor) Indicates the instantaneous power factor. The ```meter_powerfactor``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 4 configuration parameters available in the PAN08. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Watt meter report interval (5s) | Interval (x5 seconds) to send out watt meter report | | 2 | KWH Meter Report Interval (10min) | Interval (x10 minutes) to send out KWH Meter Report | | 3 | Threshold for Load Caution (10mA) | Threshold (x0.01A) of current for Load Caution | | 4 | Threshold of KWh for Load Caution | | ### Parameter 1: Watt meter report interval (5s) Interval (x5 seconds) to send out watt meter report Values in the range 1 to 32767 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_1_2``` and is of type ```INTEGER```. ### Parameter 2: KWH Meter Report Interval (10min) Interval (x10 minutes) to send out KWH Meter Report Values in the range 1 to 32767 may be set. The manufacturer defined default value is ```6```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Threshold for Load Caution (10mA) Threshold (x0.01A) of current for Load Caution Values in the range 1 to 1100 may be set. The manufacturer defined default value is ```1100```. This parameter has the configuration ID ```config_3_2``` and is of type ```INTEGER```. ### Parameter 4: Threshold of KWh for Load Caution Values in the range 1 to 10000 may be set. The manufacturer defined default value is ```10000```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The PAN08 supports 1 association group. ### Group 1: Blind Control Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [German Instructions](https://www.cd-jackson.com/zwave_device_uploads/924/Z-Wave-Anleitung-Philio-Relais-Unterputzeinsatz-Jalousie-DE.pdf) * [US Manual](https://www.cd-jackson.com/zwave_device_uploads/924/ZIPATO-PAN08-manuel-US.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/924).