--- layout: documentation title: NZW97 - ZWave --- {% include base.html %} # NZW97 Inovelli Outdoor Smart Plug (2 Channel) This describes the Z-Wave device *NZW97*, manufactured by *Willis Electric Co., Ltd.* with the thing type UID of ```willis_nzw97_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![NZW97 product image](https://www.cd-jackson.com/zwave_device_uploads/791/791_default.png) The NZW97 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview 2 Controllable Outlets Outdoor IP65 20 cm Cord High Temp Protection (OFF at 105°C) Last Power State (Possible DEFAULT) 120 VAC, 60 Hz 908.42 MHz Max Load Outlet #1 1800W (15A) Resistive Max Load Outlet #2 1800W (15A) Resistive Max Simultaneous Load 15A Max Range LoS 100 m Operating Temperature Range -20°C to 50°C UL E464831 FCC ID OXGZW97 ### Inclusion Information Auto-Inclusion 30 sec from power on Backup-Inclusion Press button 5 times within 1 sec (Tested to work with Network Wide Inclusion) ## Channels The following table summarises the channels available for the NZW97 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Alarm (heat) | alarm_heat | | Switch | | Switch 1 | switch_binary1 | Switch | Switch | | Switch 2 | switch_binary2 | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Alarm (heat) Indicates if a heat alarm is triggered. The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 1 configuration parameters available in the NZW97. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | LED Indicator | LED Indicator ON/OFF/Disabled | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: LED Indicator LED Indicator ON/OFF/Disabled LED Indicator ON/OFF/Disabled 00==Plug On / LED On 01==Plug On / LED Off 02==LED Disabled Values in the range 0 to 2 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_1_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V8| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/791).