--- layout: documentation title: TP-807ZG - ZWave --- {% include base.html %} # TP-807ZG Smoke + Carbon Monoxide + Natural Liquefied Gas Leak Detector This describes the Z-Wave device *TP-807ZG*, manufactured by *UFairy G.R. Tech* with the thing type UID of ```ufairy_tp807zg_00_000```. The device is in the category of *Sensor*, defining Device used to measure something. ![TP-807ZG product image](https://www.cd-jackson.com/zwave_device_uploads/837/837_default.jpg) The TP-807ZG does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview Smoke / Carbon Monoxide / Natural Liquefied Gas Leak Detector ### Inclusion Information press the button 3 times quickly ### Exclusion Information press the button 3 times quickly ### Wakeup Information The TP-807ZG does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. ## Channels The following table summarises the channels available for the TP-807ZG -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Binary Sensor | sensor_binary | Door | Switch | | Alarm (CO) | alarm_co | Door | Switch | ### Binary Sensor Indicates if a sensor has triggered. The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Triggered | | OFF | Untriggered | ### Alarm (CO) Indicates if the carbon monoxide alarm is triggered. The ```alarm_co``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_SENSOR_BINARY_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ALARM_V4| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [Manual 1](https://www.cd-jackson.com/zwave_device_uploads/837/TP-807ZG-1.pdf) * [Manual 2](https://www.cd-jackson.com/zwave_device_uploads/837/TP-807ZG-2.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/837).