--- layout: documentation title: TZ66D - ZWave --- {% include base.html %} # TZ66D Dual Paddle Wall Switch This describes the Z-Wave device *TZ66D*, manufactured by *TKB Home* with the thing type UID of ```tkb_tz66d_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. The TZ66D supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/157) to improve the documentation. ## Channels The following table summarises the channels available for the TZ66D -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 9 configuration parameters available in the TZ66D. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Ignore start level | Ignore start level when transmitting a dim command to the switch | | 2 | Suspend Group 4 | Disable transmitting commands to devices in association group 4 | | 3 | Blue LED light Behavior | Blue LED light Behavior. Default is Night Light (led on when switch off) | | 4 | Invert Switch | To change the top of the switch to off and the botton to on | | 14 | Enable Shade Control Group 2 | Enable the control of shade devices in association group 2 when this option is activated | | 15 | Enable Shade Control Group 3 | Enable the control of shade devices in association group 3 when this option is activated | | 19 | Blue LED light behavior on transmission | Defines the behavior of the blue LED when transmission of data | | 20 | Poll Group 2 Interval (minutes) | Polling Interval in minutes (default 2) | | 22 | Poll Group 2 | Defines if the device will poll association Group 2 at the interval defined in parameter 20 | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Ignore start level Ignore start level when transmitting a dim command to the switch The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Ignore | | 1 | Don't ignore | The manufacturer defined default value is ```1``` (Don't ignore). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Suspend Group 4 Disable transmitting commands to devices in association group 4 Setting this parameter will disable transmitting commands to devices in association group 4 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Transmit to group 4 | | 1 | Disable transmitting to group 4 | The manufacturer defined default value is ```0``` (Transmit to group 4). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Blue LED light Behavior Blue LED light Behavior. Default is Night Light (led on when switch off) Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Led on when switch on | | 1 | Night light | The manufacturer defined default value is ```0``` (Led on when switch on). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Invert Switch To change the top of the switch to off and the botton to on The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | ON on top | | 1 | OFF on top | The manufacturer defined default value is ```0``` (ON on top). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 14: Enable Shade Control Group 2 Enable the control of shade devices in association group 2 when this option is activated The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Inactive | | 1 | Shade Control | The manufacturer defined default value is ```0``` (Inactive). This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: Enable Shade Control Group 3 Enable the control of shade devices in association group 3 when this option is activated The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Inactive | | 1 | Shade Control | The manufacturer defined default value is ```0``` (Inactive). This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 19: Blue LED light behavior on transmission Defines the behavior of the blue LED when transmission of data The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | LED does not blinks on activity | | 1 | LED blinks on activity all the time | | 2 | LED blinks on activity 1 second | The manufacturer defined default value is ```2``` (LED blinks on activity 1 second). This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ### Parameter 20: Poll Group 2 Interval (minutes) Polling Interval in minutes (default 2) Values in the range 1 to 255 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 22: Poll Group 2 Defines if the device will poll association Group 2 at the interval defined in parameter 20 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```1``` (Enabled). This parameter has the configuration ID ```config_22_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The TZ66D supports 4 association groups. ### Group 1: Group 1 Association group 1 supports 5 nodes. ### Group 2: Group 2 Association group 2 supports 5 nodes. ### Group 3: Group 3 Association group 3 supports 5 nodes. ### Group 4: Group 4 Association group 4 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/157/manualtkbtz66d-141017030346-conversion-gate02.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/157).