--- layout: documentation title: CT101 - ZWave --- {% include base.html %} # CT101 Z-Wave Thermostat This describes the Z-Wave device *CT101*, manufactured by *Radio Thermostat Company of America (RTC)* with the thing type UID of ```rtc_ct101_00_000```. The device is in the category of *HVAC*, defining Air condition devices, Fans. ![CT101 product image](https://www.cd-jackson.com/zwave_device_uploads/98/98_default.jpg) The CT101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/98) to improve the documentation. ## Channels The following table summarises the channels available for the CT101 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature | | Thermostat mode | thermostat_mode | Temperature | Number | | Operating State | thermostat_state | Temperature | Number | | Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature | | Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature | | Thermostat fan mode | thermostat_fanmode | | | | Thermostat fan state | thermostat_fanstate | | | | Battery Level | battery-level | Battery | Number | | Clock Time Offset | time_offset | Temperature | Number | | Sensor (temperature) 1 | sensor_temperature1 | Temperature | Number:Temperature | | Thermostat mode 1 | thermostat_mode1 | Temperature | Number | | Operating State 1 | thermostat_state1 | Temperature | Number | | Setpoint (cooling) 1 | thermostat_setpoint1 | Temperature | Number:Temperature | | Setpoint (heating) 1 | thermostat_setpoint1 | Temperature | Number:Temperature | | Thermostat fan mode 1 | thermostat_fanmode1 | | | | Thermostat fan state 1 | thermostat_fanstate1 | | | | Battery Level | battery-level | Battery | Number | | Clock Time Offset 1 | time_offset1 | Temperature | Number | | Sensor (relative humidity) 2 | sensor_relhumidity2 | Humidity | Number | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat mode Sets the thermostat. The ```thermostat_mode``` channel supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Operating State Sets the thermostat operating state. The ```thermostat_state``` channel supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Idle | | 1 | Heating | | 2 | Cooling | | 3 | Fan Only | | 4 | Pending Heat | | 5 | Pending Cool | | 6 | Vent / Economiser | ### Setpoint (cooling) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Setpoint (heating) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat fan mode Channel type information on this channel is not found. ### Thermostat fan state Channel type information on this channel is not found. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ### Clock Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category. ### Sensor (temperature) 1 Indicates the current temperature. The ```sensor_temperature1``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat mode 1 Sets the thermostat. The ```thermostat_mode1``` channel supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Operating State 1 Sets the thermostat operating state. The ```thermostat_state1``` channel supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Idle | | 1 | Heating | | 2 | Cooling | | 3 | Fan Only | | 4 | Pending Heat | | 5 | Pending Cool | | 6 | Vent / Economiser | ### Setpoint (cooling) 1 Sets the thermostat setpoint. The ```thermostat_setpoint1``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Setpoint (heating) 1 Sets the thermostat setpoint. The ```thermostat_setpoint1``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat fan mode 1 Channel type information on this channel is not found. ### Thermostat fan state 1 Channel type information on this channel is not found. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level1``` channel supports the ```Number``` item and is in the ```Battery``` category. ### Clock Time Offset 1 Provides the current time difference for the devices time. The ```time_offset1``` channel supports the ```Number``` item and is in the ```Temperature``` category. ### Sensor (relative humidity) 2 Indicates the current relative humidity. The ```sensor_relhumidity2``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 4 configuration parameters available in the CT101. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Temperature Reporting Threshold | Reporting threshold for changes in the ambient temperature. | | 3 | Utility Lock Enable/Disable | Prevents setpoint changes at thermostat. | | 7 | Thermostat Swing Temperature | Variance allowed from setpoint | | 9 | Thermostat Recovery Mode | Fast or Economy recovery mode. | ### Parameter 1: Temperature Reporting Threshold Reporting threshold for changes in the ambient temperature. This value determines the reporting threshold when association reporting is enabled. Unsupported values will be ignored. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | 0.5° | | 2 | 1.0° | | 3 | 1.5° | | 4 | 2.0° | The manufacturer defined default value is ```2``` (1.0°). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 3: Utility Lock Enable/Disable Prevents setpoint changes at thermostat. If set to 0, the utility lock is disabled, all other values, 1-255, will enable the utility lock.  This will prevent changes to the setpoint at the thermostat screen. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Utility lock disabled | | 1 | Utility lock enabled | The manufacturer defined default value is ```0``` (Utility lock disabled). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 7: Thermostat Swing Temperature Variance allowed from setpoint The thermostat swing temperature is in units of 0.5 degrees Fahrenheit. A value of 0x01 is 0.05F and 0x02 is 1.0F. The supported values may vary from thermostat to thermostat but typically the allowed values are 0.5F (0x01) to 4.0F (0x08). The Thermostat Swing Temperature configuration command sets swing temperature on the thermostat setpoint. The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | 0.5° | | 2 | 1.0° | | 3 | 1.5° | | 4 | 2.0° | | 5 | 2.5° | | 6 | 3.0° | | 7 | 3.5° | | 8 | 4.0° | The manufacturer defined default value is ```2``` (1.0°). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 9: Thermostat Recovery Mode Fast or Economy recovery mode. The Thermostat Recovery Mode can be either fast (0x01) or economy (0x02). The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Fast recovery Mode | | 2 | Economy recovery Mode | The manufacturer defined default value is ```2``` (Economy recovery Mode). This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The CT101 supports 1 association group. ### Group 1: Group 1 Association group 1 supports 2 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/98/CT101-IBIE-18jun12-revised.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/98).