--- layout: documentation title: Reitz 05431 - ZWave --- {% include base.html %} # Reitz 05431 Duewi ZW BJ ES 1000 / Reitz 05431 / ZWave.me 05457 Single button wall switch This describes the Z-Wave device *Reitz 05431*, manufactured by *Reitz-Group.de* with the thing type UID of ```reitz_05431_00_000```. The Reitz 05431 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/55) to improve the documentation. ## Channels The following table summarises the channels available for the Reitz 05431 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 12 configuration parameters available in the Reitz 05431. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Set LED indication mode | | | 2 | Automatic switch off | If not zero, automatically switch off after a user defined time | | 3 | Function of RF off command | Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the | | 4 | Switch on dimming by buttons | Defines if the switch should change it state to on/off if it is dimmed by buttons | | 5 | Switch on dimming by buttons | Defines if the switch should restore switch state to the last state prior to device power off (power cycle). | | 10 | Typical click timeout | Typical time used to differentiate click, hold, double and triple clicks Defined in 10ms ticks. | | 11 | Invert buttons | | | 12 | Switch by buttons | If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch w | | 13 | Action on button single press or hold | Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. | | 14 | Action on button double press or hold | Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be | | 15 | Send the following switch all commands | | | 16 | What to do on button Down press | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Set LED indication mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Show switch state | | 2 | Night mode | | 3 | Remote by indicator command class | The manufacturer defined default value is ```3``` (Remote by indicator command class). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Automatic switch off If not zero, automatically switch off after a user defined time Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Function of RF off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch OFF | | 1 | Ignore | | 2 | Switch ON | | 3 | Switch on if load is off else switch off | The manufacturer defined default value is ```0``` (Switch OFF). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Switch on dimming by buttons Defines if the switch should change it state to on/off if it is dimmed by buttons The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | Yes (Default) | The manufacturer defined default value is ```1``` (Yes (Default)). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Switch on dimming by buttons Defines if the switch should restore switch state to the last state prior to device power off (power cycle). The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No, turn off | | 1 | Yes (Default) | The manufacturer defined default value is ```1``` (Yes (Default)). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 10: Typical click timeout Typical time used to differentiate click, hold, double and triple clicks Defined in 10ms ticks. Values in the range 1 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Invert buttons The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | Yes | The manufacturer defined default value is ```0``` (No). This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Switch by buttons If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch w The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | By single press and hold | | 2 | By double press and hold | The manufacturer defined default value is ```1``` (By single press and hold). This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Action on button single press or hold Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Switch On, Off and dim using Basic Set | | 2 | Switch All | | 3 | Send Scenes | | 4 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default) | | 5 | Send Preconfigured Scenes | The manufacturer defined default value is ```4``` (Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)). This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Action on button double press or hold Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled (Default) | | 1 | Switch On, Off and dim using Basic Set | | 2 | Switch All | | 3 | Send Scenes | | 4 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) | | 5 | Send Preconfigured Scenes | The manufacturer defined default value is ```0``` (Disabled (Default)). This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: Send the following switch all commands The following option values may be configured -: | Value | Description | |--------|-------------| | -1 | Switch all on and off | | 0 | Switch off only | | 1 | Switch on only | The manufacturer defined default value is ```1``` (Switch on only). This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 16: What to do on button Down press The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch off (Default) | | 1 | Switch On if load is Off, else switch Off | | 3 | Switch on | The manufacturer defined default value is ```1``` (Switch On if load is Off, else switch Off). This parameter has the configuration ID ```config_16_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The Reitz 05431 supports 3 association groups. ### Group 1: Group 1 Association group 1 supports 8 nodes. ### Group 2: Group 2 Association group 2 supports 8 nodes. ### Group 3: Group 3 Association group 3 supports 8 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_PROTECTION_V1| | | COMMAND_CLASS_HAIL_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/55/Duwiswitch.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/55).