--- layout: documentation title: ZMNHCA - ZWave --- {% include base.html %} # ZMNHCA Flush Shutter This describes the Z-Wave device *ZMNHCA*, manufactured by *[Goap](http://www.qubino.com/)* with the thing type UID of ```qubino_zmnhca_00_000```. The device is in the category of *Blinds*, defining Roller shutters, window blinds, etc.. The ZMNHCA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/635) to improve the documentation. ## Channels The following table summarises the channels available for the ZMNHCA -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Blinds Control | blinds_control | Blinds | Rollershutter | | Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature | | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | switch | switch_binary1 | Switch | Switch | | Blinds Control | blinds_control1 | Blinds | Rollershutter | | Temperatur Sensor | sensor_temperature1 | Temperature | Number:Temperature | | Electric meter (watts) | meter_watts1 | Energy | Number | | Electric meter (kWh) | meter_kwh1 | Energy | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Blinds Control Provides start / stop control of blinds. The ```blinds_control``` channel supports the ```Rollershutter``` item and is in the ```Blinds``` category. ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### switch Switch the power on and off. The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Blinds Control Provides start / stop control of blinds. The ```blinds_control1``` channel supports the ```Rollershutter``` item and is in the ```Blinds``` category. ### Temperatur Sensor Indicates the current temperature. The ```sensor_temperature1``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 12 configuration parameters available in the ZMNHCA. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 10 | ALL ON / ALL OFF | Responds to commands ALL ON / ALL OFF from Main Controller | | 40 | - Power reporting in Watts on power change for Q1 or Q2 | Power consumption change threshold for sending updates | | 42 | Power reporting in Watts by time interval for Q1 or Q2 | Power reporting in Watts by time interval for Q1 or Q2 | | 71 | Operating modes | Operation Mode (Shutter or Venetian) | | 72 | Slats tilting full turn time | Slat full turn time in tenths of a second. | | 73 | Slats position | Slats position | | 74 | Motor moving up/down time | Shutter motor moving time of complete opening or complete closing | | 76 | Motor operation detection | Power threshold | | 78 | Forced Shutter calibration | 0 to 1 a Shutter enters the calibration mode | | 80 | Reporting to controller | reports regarding to main controller | | 85 | Power consumption max delay time | max time before motor power consumption is read | | 90 | Relay delay time | This parameter defines the time delay between output relay switching | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 10: ALL ON / ALL OFF Responds to commands ALL ON / ALL OFF from Main Controller Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Available config. parameters (data type is 2 Byte DEC): *  default value 255 *  255 - ALL ON active, ALL OFF active. *  0 - ALL ON is not active, ALL OFF is not active *  1 - ALL ON is not active ALL OFF active *  2 - ALL ON active ALL OFF is not active The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | 0 - ALL ON is not active ALL OFF is not active | | 1 | 1 - ALL ON is not active ALL OFF active | | 2 | 2 - ALL ON is not active ALL OFF is not active | | 255 | 255 - ALL ON active, ALL OFF active | The manufacturer defined default value is ```255``` (255 - ALL ON active, ALL OFF active). This parameter has the configuration ID ```config_10_2``` and is of type ```INTEGER```. ### Parameter 40: - Power reporting in Watts on power change for Q1 or Q2 Power consumption change threshold for sending updates Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. Set value means percentage, set value from 0 – 100 = 0% - 100%. Available configuration parameters (data type is 1 Byte DEC): *  default value 1 *  0 - reporting disabled *  1 - 100 = 1% - 100% Reporting enabled. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. Values in the range 1 to 100 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_40_1``` and is of type ```INTEGER```. ### Parameter 42: Power reporting in Watts by time interval for Q1 or Q2 Power reporting in Watts by time interval for Q1 or Q2 Set value means time interval (0 – 32767) in seconds, when power report is send. Available configuration parameters (data type is 2 Byte DEC): *  default value 300 = 300s *  0 - Reporting Disabled *  1 - 32767 = 1 second - 32767 seconds. Reporting enabled, power report is send with time interval set by entered value. Values in the range 0 to 32767 may be set. The manufacturer defined default value is ```300```. This parameter has the configuration ID ```config_42_2``` and is of type ```INTEGER```. ### Parameter 71: Operating modes Operation Mode (Shutter or Venetian) This parameter defines selection between two available operating modes. Available configuration parameters (data type is 1 Byte DEC): *  default value 0 *  0 - Shutter mode *  1 - venetian mode (up/down and slate rotation) NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module! The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | 0 – Shutter mode | | 1 | 1 – Venetian mode (up/down and slate rotation) | The manufacturer defined default value is ```0``` (0 – Shutter mode). This parameter has the configuration ID ```config_71_1``` and is of type ```INTEGER```. ### Parameter 72: Slats tilting full turn time Slat full turn time in tenths of a second. This parameter defines the time necessary for slats to make full turn (180 degrees). Available configuration parameters (data type is 2 Byte DEC): * default value 150 = 1,5 seconds * 0 - tilting time disabled * 1 - 32767 = 0,01seconds - 327,67 seconds NOTE: If time set is too high, this will result that after full turn, Shutter will start move up/down, for time remaining. Values in the range 0 to 32767 may be set. The manufacturer defined default value is ```150```. This parameter has the configuration ID ```config_72_2``` and is of type ```INTEGER```. ### Parameter 73: Slats position Slats position This parameter defines slats position after up/down movement through Z-wave or push-buttons. Available configuration parameters (data type is 1 Byte DEC): *  default value 1 *  0 - Slats return to previously set position only in case of UI control. *  1 - Slats return to previously set position in case of UI control, push button operation or when the limit switch is reached. * 2 - Slats return to previously set position in case of UI control, push button, when the limit switch is reached or after receiving a “STOP” control frame (Switch Multilevel Stop Level Change) from UI The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | previously set position only in case of UI control | | 1 | position in case of UI control, push | | 2 | position in case of UI control, push button | The manufacturer defined default value is ```2``` (position in case of UI control, push button). This parameter has the configuration ID ```config_73_1``` and is of type ```INTEGER```. ### Parameter 74: Motor moving up/down time Shutter motor moving time of complete opening or complete closing This parameter defines Shutter motor moving time of complete opening or complete closing. Available configuration parameters (data type is 2 Byte DEC): *  default value 0 *  0 - moving time disabled (working with limit switches) *  1 - 32767 = 0,1seconds - 3276,7seconds. After that time motor is stopped (relay goes to off state) NOTE: Important is that the reference position to manually set moving time is always Shutter lower position! Set parameter 74 to 0 and move the Shutter (using up/down push buttons or main controller UI) to the lowest desired position. On this Shutter position, set parameter 74 to time for complete opening or complete closing. At this point Shutter can be moved up (open) for set time, but can't be moved down because this position is already set as lower Shutter position. To change Shutter lower position below already set (manual recalibration), parameter 74 must be set to 0 and repeat the procedure described above. In case Shutter has limit switches, but anyhow you would like to limit opening/closing position by time, you can still do it. In case you put time that is longer that opening/closing real time limited by limit switches, Shutter will stop at limit switch, but the module relay will switch off after define time, not by Shutter limit switch. Take in consideration that in this condition, the positioning with slider through UI will not show correct Shutter position. NOTE that is not recommended using this for slates operation since its positioning can be compromised during time. Values in the range 0 to 32767 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_74_2``` and is of type ```INTEGER```. ### Parameter 76: Motor operation detection Power threshold Power threshold to be interpreted when motor reach the limit switch. Available configuration parameters (data type is 1 Byte DEC): *  default value 10 = 10W *  0 - 127 = 1-127 W. The value 0 means reaching a limit switch will not be detected NOTE: Motors with power consumption less than 0,5W could not be auto calibrated. In that case set time manually (par. 74). Values in the range 0 to 127 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_76_1``` and is of type ```INTEGER```. ### Parameter 78: Forced Shutter calibration 0 to 1 a Shutter enters the calibration mode By modifying the parameters setting from 0 to 1 a Shutter DC module enters the calibration mode. Available configuration parameters (data type is 1 Byte DEC): *  default value 0 *  1 - Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0. Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_78_1``` and is of type ```INTEGER```. ### Parameter 80: Reporting to controller reports regarding to main controller This parameter defines if reporting regarding power level, multilevel, etc,…is reported to controller or not. Available configuration parameters: default value 1 * 0 reporting to controller is disabled * 1 reporting to controller The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | reporting to controller is disabled | | 1 | reporting to controller is enabled | The manufacturer defined default value is ```1``` (reporting to controller is enabled). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 85: Power consumption max delay time max time before motor power consumption is read This parameter defines the max time before motor power consumption is read after one of the relays is switched ON. If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position,...) the relay will switch OFF. Time is defined by entering it manually. Available configuration parameters (data type is 1 Byte DEC): *  default value 8 = 800ms *  3 - 50 = 0,3seconds - 5seconds (100ms resolution) *  0 = time is set automatically Values in the range 0 to 50 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_85_1``` and is of type ```INTEGER```. ### Parameter 90: Relay delay time This parameter defines the time delay between output relay switching This parameter defines the minimum time delay between next motor movement (minimum time between switching motor off and on again). Available configuration parameters (data type is 1 Byte DEC): *  default value 5 = 500ms *  1 - 30 = 0,1seconds - 3seconds (100ms resolution) Values in the range 1 to 30 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ZMNHCA supports 5 association groups. ### Group 1: basic on/off triggered at change of the input I1 state and reflecting its state Association group 1 supports 16 nodes. ### Group 2: basic on/of triggered at change of the input I2 state and reflecting its state Association group 2 supports 16 nodes. ### Group 3: multileve triggered at changes of value of the Flush shutter position Association group 3 supports 16 nodes. ### Group 4: multilevel triggered at changes of value of slats tilting position Association group 4 supports 16 nodes. ### Group 5: default reporting group Association group 5 supports 16 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V3| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V3| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Manual](https://www.cd-jackson.com/zwave_device_uploads/635/flush-shutter-ZMNHCA2.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/635).