--- layout: documentation title: 123665 - ZWave --- {% include base.html %} # 123665 Wall Plug Meter Switch This describes the Z-Wave device *123665*, manufactured by *Popp & Co* with the thing type UID of ```popp_123665_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![123665 product image](https://www.cd-jackson.com/zwave_device_uploads/228/228_default.png) The 123665 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Controlable plug for wall outlets including energy and power meter. ### Inclusion Information Turn the controller into inclusion mode.  Press the button on the wall plug 3 times within a period of around 2 seconds. ### Exclusion Information Turn the controller into exclusion mode.  Press the button on the wall plug 3 times within a period of around 2 seconds. ## Channels The following table summarises the channels available for the 123665 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (power factor) | meter_powerfactor | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (power factor) Indicates the instantaneous power factor. The ```meter_powerfactor``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 5 configuration parameters available in the 123665. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Watt Meter Report Period | See the overview field for parameter 1 | | 2 | KWH Meter Report Period | See the overview field for parameter 2 | | 4 | Threshold of KWh for Load caution | See overview parameter 4 | | 5 | Ignore start level | | | 11 | Ignore start level | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Watt Meter Report Period See the overview field for parameter 1 If the setting is configured for 1hour (set value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. (in seconds) The following option values may be configured, in addition to values in the range 0 to 65535 -: | Value | Description | |--------|-------------| | 99999 | TEST | The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_1_2``` and is of type ```INTEGER```. ### Parameter 2: KWH Meter Report Period See the overview field for parameter 2 if the setting is configured for 1hour (set value =6), the device will report its Accumulated Power Consumption (KW/h) every hour (in seconds) Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```6```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 4: Threshold of KWh for Load caution See overview parameter 4 This is a warning when the KWh of load over the preset threshold value, if the Accumulated Power Consumption exceeds the setting value the device will send a warning alarm command to the controller. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```10000```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 5: Ignore start level The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch Off | | 1 | Last Switch State (Default) | | 2 | Switch On | The manufacturer defined default value is ```1``` (Last Switch State (Default)). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 11: Ignore start level The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled (Default) | The manufacturer defined default value is ```1``` (Enabled (Default)). This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 123665 supports 1 association group. ### Group 1: Switch State Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [English Manual](https://www.cd-jackson.com/zwave_device_uploads/228/POP-123665.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/228).