--- layout: documentation title: 123580 - ZWave --- {% include base.html %} # 123580 Wall Plug Dimmer This describes the Z-Wave device *123580*, manufactured by *Popp & Co* with the thing type UID of ```popp_123580_00_000```. The 123580 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/232) to improve the documentation. ## Channels The following table summarises the channels available for the 123580 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Dimmer | switch_dimmer | DimmableLight | Dimmer | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ## Device Configuration The following table provides a summary of the 17 configuration parameters available in the 123580. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Set LED indication mode | | | 2 | Automatic switch off time | If not zero, automatically switch off after a user defined time (in seconds) | | 3 | RF Off command | Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the | | 4 | Ignore start level | | | 5 | Speed for fast dimming | Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. Set in 10ms steps. | | 6 | Speed for slow dimming | Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. Set in 10ms steps. | | 7 | Behavior when ON received | Defines the dim level on command 'ON'. On default he dimmer restores last dim level. This parameter allows configuring the maximum level on second On command (if already On) or to always switch on to maximum level. | | 8 | Baby dimming time | Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action. If enabled, the device will wait for a click timeout to see if the second click would be pressed. This w | | 9 | Baby target level | Target percentage level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light. | | 10 | Baby target level | Typical time used to differentiate click, hold, double and triple clicks. Set in 10ms steps. | | 17 | Limit minimum light level | Minimum level should be greater than maximum. | | 18 | Limit maximum light level | Maximum level should be greater than minimum. Set to 0 to act as a switch. | | 19 | Dim Level on 'Switch On' | defines how the dimmer hall react on a simple ON Command. Set to 0 to restore last level, otherwise sets dim level. | | 51 | Pause before pulse | NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 1. For other bulbs use default value. | | 52 | Pause after pulse | NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value. | | 53 | Pulse width | NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value. | | 54 | Pulse type | NB: Do not touch these settings if you are not sure what they mean! | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Set LED indication mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | On when switch on | | 2 | On when switch off | | 3 | Operated by command | The manufacturer defined default value is ```1``` (On when switch on). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Automatic switch off time If not zero, automatically switch off after a user defined time (in seconds) Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: RF Off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch OFF | | 1 | Ignore | | 2 | Switch ON | | 3 | Switch on if load is off else switch off | The manufacturer defined default value is ```0``` (Switch OFF). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Ignore start level The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | Yes | The manufacturer defined default value is ```1``` (Yes). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Speed for fast dimming Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. Set in 10ms steps. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Speed for slow dimming Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. Set in 10ms steps. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: Behavior when ON received Defines the dim level on command 'ON'. On default he dimmer restores last dim level. This parameter allows configuring the maximum level on second On command (if already On) or to always switch on to maximum level. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Set to last dim level | | 1 | If on already, set to maximum | | 2 | Always maximum dim level | The manufacturer defined default value is ```0``` (Set to last dim level). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Baby dimming time Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action. If enabled, the device will wait for a click timeout to see if the second click would be pressed. This w Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Baby target level Target percentage level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Baby target level Typical time used to differentiate click, hold, double and triple clicks. Set in 10ms steps. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 17: Limit minimum light level Minimum level should be greater than maximum. Values in the range 1 to 95 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_17_1``` and is of type ```INTEGER```. ### Parameter 18: Limit maximum light level Maximum level should be greater than minimum. Set to 0 to act as a switch. Values in the range 0 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_18_1``` and is of type ```INTEGER```. ### Parameter 19: Dim Level on 'Switch On' defines how the dimmer hall react on a simple ON Command. Set to 0 to restore last level, otherwise sets dim level. Values in the range 0 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ### Parameter 51: Pause before pulse NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 1. For other bulbs use default value. Values in the range 5 to 60 may be set. The manufacturer defined default value is ```28```. This parameter has the configuration ID ```config_51_1``` and is of type ```INTEGER```. ### Parameter 52: Pause after pulse NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value. Values in the range 5 to 60 may be set. The manufacturer defined default value is ```28```. This parameter has the configuration ID ```config_52_1``` and is of type ```INTEGER```. ### Parameter 53: Pulse width NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value. Values in the range 3 to 20 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_53_1``` and is of type ```INTEGER```. ### Parameter 54: Pulse type NB: Do not touch these settings if you are not sure what they mean! The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Long | | 1 | Short | The manufacturer defined default value is ```0``` (Long). This parameter has the configuration ID ```config_54_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 123580 supports 1 association group. ### Group 1: Switch State Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V2| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_PROTECTION_V1| | | COMMAND_CLASS_NODE_NAMING_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| | --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/232).