--- layout: documentation title: 009402 - ZWave --- {% include base.html %} # 009402 10 Year Smoke Detector with Siren Function This describes the Z-Wave device *009402*, manufactured by *Popp & Co* with the thing type UID of ```popp_009402_00_000```. This version of the device is limited to firmware versions below 1.1 The device is in the category of *Smoke Detector*, defining Smoke detectors. ![009402 product image](https://www.cd-jackson.com/zwave_device_uploads/424/424_default.jpg) The 009402 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/424) to improve the documentation. ## Channels The following table summarises the channels available for the 009402 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Binary Sensor | sensor_binary | Door | Switch | | Smoke Alarm | alarm_smoke | Smoke | Switch | | Battery Level | battery-level | Battery | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Binary Sensor Indicates if a sensor has triggered. The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Triggered | | OFF | Untriggered | ### Smoke Alarm Indicates if a smoke is triggered. The ```alarm_smoke``` channel supports the ```Switch``` item and is in the ```Smoke``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ## Device Configuration The following table provides a summary of the 4 configuration parameters available in the 009402. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Siren alarm sequence interval | The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. | | 2 | Siren alarm tone length | The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. | | 3 | Value of On-Command | | | 4 | Value of Off-Command | | ### Parameter 1: Siren alarm sequence interval The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. Values in the range 3 to 129 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Siren alarm tone length The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```8```. This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Value of On-Command Values in the range 0 to 99 may be set. The manufacturer defined default value is ```99```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Value of Off-Command Values in the range 0 to 99 may be set. The manufacturer defined default value is ```99```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 009402 supports 3 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 4 nodes. ### Group 2: Alarm Reports Association group 2 supports 4 nodes. ### Group 3: Switching Command when Alarm Association group 3 supports 4 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SENSOR_BINARY_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| Linked to BASIC| | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/424/popp-009402.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/424).