--- layout: documentation title: BTZEUMV1 - ZWave --- {% include base.html %} # BTZEUMV1 Danalock Universal Module V1 This describes the Z-Wave device *BTZEUMV1*, manufactured by *[Poly-control](https://www.danalock.com/)* with the thing type UID of ```polycontrol_danalockuniversalmodulve1_00_000```. The device is in the category of *Lock*, defining Devices whose primary pupose is locking something. ![BTZEUMV1 product image](https://www.cd-jackson.com/zwave_device_uploads/868/868_default.jpg) The BTZEUMV1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. ## Overview The universal module enables the control of existing electrical locking systems via smartphone. It is a circuit board with a relay to switch potential-free contacts. The module is connected near the lock system and actuates engine locks, garage doors, digital cylinders or the door number. ### Inclusion Information To add or include the Danalock into a Z-Wave network 1. Set the controller in inclusion mode 2. Push the switch once until you hear two beeps.  ### Exclusion Information To add or exclude the Danalock into a Z-Wave network 1. Set the controller in inclusion mode 2. Push the switch once until you hear two beeps. ## Channels The following table summarises the channels available for the BTZEUMV1 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Door Lock | lock_door | Door | Switch | | Alarm (access) | alarm_access | Door | Switch | | Battery Level | battery-level | Battery | Number | | Clock Time Offset | time_offset | Temperature | Number | ### Door Lock Lock and unlock the door. The ```lock_door``` channel supports the ```Switch``` item and is in the ```Door``` category. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Locked | | OFF | Unlocked | ### Alarm (access) Indicates if the access control alarm is triggered. The ```alarm_access``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ### Clock Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The BTZEUMV1 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_APPLICATION_STATUS_V1| | | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1| | | COMMAND_CLASS_SCHEDULE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_DOOR_LOCK_V1| | | COMMAND_CLASS_USER_CODE_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V3| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_TIME_V1| | | COMMAND_CLASS_TIME_PARAMETERS_V1| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Manual](https://www.cd-jackson.com/zwave_device_uploads/868/danalock-universalmodul-v1.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/868).