--- layout: documentation title: PST02A - ZWave --- {% include base.html %} # PST02A Slim Multi-Sensor (PIR/Door/Temperature/Illumination) This describes the Z-Wave device *PST02A*, manufactured by *[Philio Technology Corp](http://www.philio-tech.com/)* with the thing type UID of ```philio_pst02a_00_000```. The PST02A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The PST02A does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview ### Wakeup Information The PST02A does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. ## Channels The following table summarises the channels available for the PST02A -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Door/Window Sensor | sensor_door | Door | Contact | | Motion Sensor | alarm_motion | Door | Switch | | Tamper Alarm | alarm_tamper | | Switch | | Sensor (luminance) | sensor_luminance | | Number | | Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature | | Alarm (Access Control) | alarm_access | Door | Switch | | Alarm (Burglar) | alarm_burglar | Door | Switch | | Battery Level | battery-level | Battery | Number | ### Door/Window Sensor Indicates if the door/window is open or closed. The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Contact``` item type -: | Value | Label | |-------|-----------| | OPEN | Open | | CLOSED | Closed | ### Motion Sensor Indicates if a motion alarm is triggered. The ```alarm_motion``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Tamper Alarm Indicates if the tamper alarm is triggered. The ```alarm_tamper``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Sensor (luminance) Indicates the current light reading. The ```sensor_luminance``` channel supports the ```Number``` item. This is a read only channel so will only be updated following state changes from the device. ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Alarm (Access Control) Indicates if the access control alarm is triggered. The ```alarm_access``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Alarm (Burglar) Indicates if the burglar alarm is triggered. The ```alarm_burglar``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ## Device Configuration The following table provides a summary of the 15 configuration parameters available in the PST02A. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Basic Set Level | Setting the BASIC command value to turn on the light. | | 3 | PIR Sensitivity | Parameter to set the sensitivity for the PIR (Passiv Infrared Sensor). 0 = Disable the PIR motion detection. 1 - 99 = 1 means the lowest sensitivity, 99 means the highest sensitivity High sensitivity means de | | 4 | Light Threshold | Setting the illumination threshold to turn on the light. When the event triggers and the environment illumination is lower than the threshold, the device will turn on the light. 0 = Turn off illumination detected function and never turn | | 5 | Operation Mode | Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 means normal mode. Notice: Ignored if DIP Switch is not set to Customer Mode. Bit 2: Disable the door/window function. 1 | | 6 | Multi-Sensor Function Switch | Parameter to set the sensor functions. * Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable * Bit 1: Disable PIR integrate Illumination to turn on the | | 7 | Customer Function | Parameter to set the Customer Function. Bit 0: Reserved. Bit 1: Enable sending motion OFF report. 0: Disable, 1: Enable. Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, | | 8 | PIR Re-Detect Interval Time | In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds). * 1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds). | | 9 | Turn Off Light Time | After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected. * 0 = Never send turn off light command. * 1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds | | 10 | Auto Report Battery Time | The interval time for auto reporting the battery level. * 0 = Turn off auto report battery. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 11 | Auto Report Door/Window State Time | The interval time for auto reporting the door/window state. * 0 = Turn off auto report door/window state. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 12 | Auto Report Illumination Time | The Interval time for auto reporting the illumination state. 0 = Turn off auto report illumination. 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 13 | Auto Report Temperature Time | The interval time for auto reporting the temperature state. * 0 = Turn off auto report temperature. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 20 | Auto Report Tick Interval | The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. * 0 = Turn off all auto report functions. * 1-255 = Interval time for each tick. Default is 30. | | 21 | Temperature Differential Report | The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Enabling this functionality will cause s | | 22 | Illumination Differential Report | The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual. | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | ### Parameter 2: Basic Set Level Setting the BASIC command value to turn on the light. * 0 = Turn off the light. * 1 - 100 = For dimmers 1 to 100 means the light strength. * 255 = turns on the light. (Default) The following option values may be configured, in addition to values in the range 1 to 100 -: | Value | Description | |--------|-------------| | 0 | Turn light OFF | | 255 | Turn light ON | The manufacturer defined default value is ```255``` (Turn light ON). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: PIR Sensitivity Parameter to set the sensitivity for the PIR (Passiv Infrared Sensor). 0 = Disable the PIR motion detection. 1 - 99 = 1 means the lowest sensitivity, 99 means the highest sensitivity High sensitivity means de The following option values may be configured, in addition to values in the range 0 to 99 -: | Value | Description | |--------|-------------| | 0 | Disable Motion Detection | The manufacturer defined default value is ```70```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Light Threshold Setting the illumination threshold to turn on the light. When the event triggers and the environment illumination is lower than the threshold, the device will turn on the light. 0 = Turn off illumination detected function and never turn The following option values may be configured, in addition to values in the range 0 to 100 -: | Value | Description | |--------|-------------| | 0 | Disable Illumination Detection | The manufacturer defined default value is ```100```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Operation Mode Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 means normal mode. Notice: Ignored if DIP Switch is not set to Customer Mode. Bit 2: Disable the door/window function. 1 The following option values may be configured, in addition to values in the range 0 to 127 -: | Value | Description | |--------|-------------| | 10 | Preset: Celsius and LED on = Bits: 00001010 = 10 | The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Multi-Sensor Function Switch Parameter to set the sensor functions. * Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable * Bit 1: Disable PIR integrate Illumination to turn on the Values in the range 0 to 127 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: Customer Function Parameter to set the Customer Function. Bit 0: Reserved. Bit 1: Enable sending motion OFF report. 0: Disable, 1: Enable. Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, The default value has to be 20. With 20 the contact sensor throws a correct value. The following option values may be configured, in addition to values in the range 0 to 127 -: | Value | Description | |--------|-------------| | 22 | Preset: PIR Super Sensitivity and Binary Report and Motion Off Report | The manufacturer defined default value is ```20```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: PIR Re-Detect Interval Time In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds). * 1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds). Values in the range 1 to 127 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Turn Off Light Time After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected. * 0 = Never send turn off light command. * 1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds Values in the range 0 to 127 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Auto Report Battery Time The interval time for auto reporting the battery level. * 0 = Turn off auto report battery. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 0 to 127 may be set. The manufacturer defined default value is ```12```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Auto Report Door/Window State Time The interval time for auto reporting the door/window state. * 0 = Turn off auto report door/window state. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 0 to 127 may be set. The manufacturer defined default value is ```12```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Auto Report Illumination Time The Interval time for auto reporting the illumination state. 0 = Turn off auto report illumination. 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set. The manufacturer defined default value is ```12```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Auto Report Temperature Time The interval time for auto reporting the temperature state. * 0 = Turn off auto report temperature. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set. The manufacturer defined default value is ```12```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 20: Auto Report Tick Interval The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. * 0 = Turn off all auto report functions. * 1-255 = Interval time for each tick. Default is 30. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 21: Temperature Differential Report The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Enabling this functionality will cause s Values in the range 0 to 127 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_21_1``` and is of type ```INTEGER```. ### Parameter 22: Illumination Differential Report The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual. Values in the range 0 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_22_1``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The PST02A supports 2 association groups. ### Group 1: Reports Association group 1 supports 8 nodes. ### Group 2: Light Control Association group 2 supports 8 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_BINARY_V2| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_MULTI_CMD_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/168/PST02-Manual-2014-09-17.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/168).