--- layout: documentation title: PAN11 - ZWave --- {% include base.html %} # PAN11 Smart Energy Plug In Switch This describes the Z-Wave device *PAN11*, manufactured by *[Philio Technology Corp](http://www.philio-tech.com/)* with the thing type UID of ```philio_pan11_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![PAN11 product image](https://www.cd-jackson.com/zwave_device_uploads/177/177_default.png) The PAN11 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/177) to improve the documentation. ## Channels The following table summarises the channels available for the PAN11 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Electric meter (power factor) | meter_powerfactor | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Electric meter (watts) | meter_watts | Energy | Number | | Reset the total power consumption | meter_reset | Energy | Switch | | Alarm | alarm_general | Door | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (power factor) Indicates the instantaneous power factor. The ```meter_powerfactor``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Reset the total power consumption Reset the meter. The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category. ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 9 configuration parameters available in the PAN11. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | W meter report period | Set automatic W meter reporting interval | | 2 | kWh meter report period | Set automatic kWh meter reporting interval. | | 3 | Threshold of Watt for load caution | Set threshold of wattage meter value for load caution . | | 4 | Threshold of kWh for Load Caution | If threshold of kWh is reached, a Meter Report will be generated | | 5 | Restore switch state mode | | | 6 | Mode of switch Off function | | | 7 | LED indication mode | | | 8 | Auto Off Timer | Auto off timer. 0 will disable the auto off function. | | 9 | RF Off command mode | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: W meter report period Set automatic W meter reporting interval If the setting is configured for 1hour (set value =720), the PAN11 will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Values in the range 0 to 32767 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_1_2``` and is of type ```INTEGER```. ### Parameter 2: kWh meter report period Set automatic kWh meter reporting interval. If the setting is configured for 1hour (set value =6), the PAN11 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Values in the range 0 to 32767 may be set. The manufacturer defined default value is ```6```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Threshold of Watt for load caution Set threshold of wattage meter value for load caution . This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN11 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.  Values in the range 10 to 1300 may be set. The manufacturer defined default value is ```1300```. This parameter has the configuration ID ```config_3_2``` and is of type ```INTEGER```. ### Parameter 4: Threshold of kWh for Load Caution If threshold of kWh is reached, a Meter Report will be generated Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting. Values in the range 1 to 10000 may be set. The manufacturer defined default value is ```10000```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 5: Restore switch state mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch Off | | 1 | Last State | | 2 | Switch On | The manufacturer defined default value is ```1``` (Last State). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Mode of switch Off function The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | SWITCH OFF commands received are ignored. | | 1 | SWITCH OFF commands received are honored. | The manufacturer defined default value is ```1``` (SWITCH OFF commands received are honored.). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: LED indication mode The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | The LED follows the state of the switch. | | 2 | LED off with load ON | | 3 | One flash mode | The manufacturer defined default value is ```1``` (The LED follows the state of the switch.). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Auto Off Timer Auto off timer. 0 will disable the auto off function. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_8_2``` and is of type ```INTEGER```. ### Parameter 9: RF Off command mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch Off | | 1 | Ignore | | 2 | Switch Toggle | | 3 | Switch On | The manufacturer defined default value is ```0``` (Switch Off). This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The PAN11 supports 1 association group. ### Group 1: Reports Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_PROTECTION_V2| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/177/phi-pan11-energyswitch.pdf) * [Philio pan11 1b Manual](https://www.cd-jackson.com/zwave_device_uploads/177/philio---pan11-1b---manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/177).