--- layout: documentation title: FT132 - ZWave --- {% include base.html %} # FT132 Dual Nano Switch with Energy Metering This describes the Z-Wave device *FT132*, manufactured by *[Fantem](http://www.oomi.com/)* with the thing type UID of ```oomi_ft132_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![FT132 product image](https://www.cd-jackson.com/zwave_device_uploads/852/852_default.png) The FT132 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Fantech Dual Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches.  In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status.  It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch.  The Dual Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. ### Inclusion Information If you want your In-Wall Smart Switch (Dual) as a non-secure device in your Z-Wave network,press the Action Button once on In-Wall Smart Switch (Dual) when you pair it to your gateway. Ifinclusion is successful, the green LED will be on for 2 seconds, and then return to a solidindication. If inclusion is unsuccessful, the red LED will be on for 2 seconds and then return to acolourful gradient. ### Exclusion Information If at some stage, your primary controller is missing or inoperable, you may wish to reset all ofyour In-Wall Smart Switch (Dual)’s settings to their factory defaults. To do this, press and holdthe Action Button for 20 seconds and then release it. Your In-Wall Smart Switch (Dual) will nowbe reset to its original settings, and the green LED will be solid for 2 seconds and then remain thecolourful gradient status as a confirmation. ## Channels The following table summarises the channels available for the FT132 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Scene Number | scene_number | | Number | | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Alarm (power) | alarm_power | Door | Switch | | Alarm (heat) | alarm_heat | | Switch | | Clock Time Offset | time_offset | Temperature | Number | | Switch 1 | switch_binary1 | Switch | Switch | | Electric meter (watts) 1 | meter_watts1 | Energy | Number | | Electric meter (volts) 1 | meter_voltage1 | Energy | Number | | Electric meter (kWh) 1 | meter_kwh1 | Energy | Number | | Electric meter (amps) 1 | meter_current1 | Energy | Number | | Switch 2 | switch_binary2 | Switch | Switch | | Electric meter (watts) 2 | meter_watts2 | Energy | Number | | Electric meter (volts) 2 | meter_voltage2 | Energy | Number | | Electric meter (kWh) 2 | meter_kwh2 | Energy | Number | | Electric meter (amps) 2 | meter_current2 | Energy | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Alarm (power) Indicates if a power alarm is triggered. The ```alarm_power``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Alarm (heat) Indicates if a heat alarm is triggered. The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Clock Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category. ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (watts) 1 Indicates the instantaneous power consumption. The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 1 Indicates the instantaneous voltage. The ```meter_voltage1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 1 Indicates the energy consumption (kWh). The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 1 Indicates the instantaneous current consumption. The ```meter_current1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (watts) 2 Indicates the instantaneous power consumption. The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 2 Indicates the instantaneous voltage. The ```meter_voltage2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 2 Indicates the energy consumption (kWh). The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 2 Indicates the instantaneous current consumption. The ```meter_current2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 22 configuration parameters available in the FT132. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | Current Overload Protection. | Current Overload Protection. | | 4 | Overheat protection | Overheat protection | | 20 | Configure the output status after re-power on it. | Configure the output status after re-power on it. | | 80 | Group 1 notifications | To set which notification would be sent to the associated devices (Group 1) | | 81 | Group 3 notifications | To set which notification would be sent to association group 3 | | 82 | Group 4 notifications | To set which notification would be sent to association group 4 | | 90 | Enables/disables parameter 91 and 92 below: | Enables/disables parameter 91 and 92 below: | | 91 | Set the threshold value of wattage. | Set the threshold value of wattage. | | 92 | Set the threshold value of wattage. | Set the threshold value of wattage. | | 100 | Set parameter 101-103 to default value | Reset the parameter 101-103 | | 101 | Set group 1 reports | To set which reports need to be sent in Report group 1 | | 102 | To set which reports need to be sent in Report group 2. | To set which reports need to be sent in Report group 2. | | 103 | To set which reports need to be sent in Report group 3 | To set which reports need to be sent in Report group 3. | | 110 | Set parameter 111-113 to default value. | Set parameter 111-113 to default value. | | 111 | Set the interval of automatic report for Report group 1. | Set the interval of automatic report for Report group 1. | | 112 | Set the interval of automatic report for Report group 2 | Set the interval of automatic report for Report group 2. | | 113 | Set the interval of automatic report for Report group 2. | Set the interval of automatic report for Report group 2. | | 120 | Configure the external switch mode for S1 | Configure the external switch mode for S1 | | 121 | Configure the external switch mode for S2. | Configure the external switch mode for S2. | | 122 | Set the control destination for external switch | Set the control destination for external switch | | 252 | Lock/unlock configuration parameters | Lock/unlock configuration parameters | | 255 | Reset the Dual Nano Switch | Reset the Dual Nano Switch | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 3: Current Overload Protection. Current Overload Protection. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```1``` (Enable). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Overheat protection Overheat protection The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 20: Configure the output status after re-power on it. Configure the output status after re-power on it. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Last status | | 1 | Always on | | 2 | Always off | The manufacturer defined default value is ```0``` (Last status). This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 80: Group 1 notifications To set which notification would be sent to the associated devices (Group 1) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Send Nothing | | 1 | Send Hail CC | | 2 | Send Basic CC report | | 3 | Send Hail CC when using the manual switch | The manufacturer defined default value is ```0``` (Send Nothing). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 81: Group 3 notifications To set which notification would be sent to association group 3 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Send Nothing | | 1 | Send Basic Set CC | The manufacturer defined default value is ```1``` (Send Basic Set CC). This parameter has the configuration ID ```config_81_1``` and is of type ```INTEGER```. ### Parameter 82: Group 4 notifications To set which notification would be sent to association group 4 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Send Nothing | | 1 | Send Basic Set CC | The manufacturer defined default value is ```1``` (Send Basic Set CC). This parameter has the configuration ID ```config_82_1``` and is of type ```INTEGER```. ### Parameter 90: Enables/disables parameter 91 and 92 below: Enables/disables parameter 91 and 92 below: The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Set the threshold value of wattage. Set the threshold value of wattage. Values in the range 0 to 60000 may be set. The manufacturer defined default value is ```25```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Set the threshold value of wattage. Set the threshold value of wattage. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 100: Set parameter 101-103 to default value Reset the parameter 101-103 Values in the range 0 to 0 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_100_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 101: Set group 1 reports To set which reports need to be sent in Report group 1 The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Send Meter Report of energy (kWh) | | 2 | Send Meter Report of wattage (W) | | 4 | Send Meter Report of voltage (V) | | 8 | Send Meter Report of current (A) | | 256 | Send Multi Channel Meter Report of wattage (W) on Channel 1 | | 512 | Send Multi Channel Meter Report of wattage (W) on Channel 2 | | 2048 | Send Multi Channel Meter Report of energy (kWh) on Channel 1 | | 4096 | Send Multi Channel Meter Report of energy (kWh) on Channel 2 | | 65536 | Send Multi Channel Meter Report of voltage (V) on Channel 1 | | 131072 | Send Multi Channel Meter Report of voltage (V) on Channel 2 | | 524288 | Send Multi Channel Meter Report of current (A) on Channel 1 | | 1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 | The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: To set which reports need to be sent in Report group 2. To set which reports need to be sent in Report group 2. The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Send Meter Report of energy (kWh) | | 2 | Send Meter Report of wattage (W) | | 4 | Send Meter Report of voltage (V) | | 8 | Send Meter Report of current (A) | | 256 | Send Multi Channel Meter Report of wattage (W) on Channel 1 | | 512 | Send Multi Channel Meter Report of wattage (W) on Channel 2 | | 2048 | Send Multi Channel Meter Report of energy (kWh) on Channel 1 | | 4096 | Send Multi Channel Meter Report of energy (kWh) on Channel 2 | | 65536 | Send Multi Channel Meter Report of voltage (V) on Channel 1 | | 131072 | Send Multi Channel Meter Report of voltage (V) on Channel 2 | | 524288 | Send Multi Channel Meter Report of current (A) on Channel 1 | | 1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 | The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_102_1``` and is of type ```INTEGER```. ### Parameter 103: To set which reports need to be sent in Report group 3 To set which reports need to be sent in Report group 3. The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Send Meter Report of voltage (V) | | 2 | Send Meter Report of current (A) | | 4 | Send Meter Report of wattage (W) | | 8 | Send Meter Report of energy (kWh) | | 256 | Send Multi Channel Meter Report of wattage (W) on Channel 1 | | 512 | Send Multi Channel Meter Report of wattage (W) on Channel 2 | | 2048 | Send Multi Channel Meter Report of energy (kWh) on Channel 1 | | 4096 | Send Multi Channel Meter Report of energy (kWh) on Channel 2 | | 65536 | Send Multi Channel Meter Report of voltage (V) on Channel 1 | | 131072 | Send Multi Channel Meter Report of voltage (V) on Channel 2 | | 524288 | Send Multi Channel Meter Report of current (A) on Channel 1 | | 1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 | The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_103_1``` and is of type ```INTEGER```. ### Parameter 110: Set parameter 111-113 to default value. Set parameter 111-113 to default value. Values in the range 0 to 0 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_110_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 111: Set the interval of automatic report for Report group 1. Set the interval of automatic report for Report group 1. Values in the range 1 to 2147483647 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Set the interval of automatic report for Report group 2 Set the interval of automatic report for Report group 2. Values in the range 1 to 2147483647 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Set the interval of automatic report for Report group 2. Set the interval of automatic report for Report group 2. Values in the range 1 to 2147483647 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Parameter 120: Configure the external switch mode for S1 Configure the external switch mode for S1 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Enter automatic identification mode | | 1 | 2-state switch mode | | 2 | 3 way switch mode | | 3 | Momentary push button mode | The manufacturer defined default value is ```0``` (Enter automatic identification mode). This parameter has the configuration ID ```config_120_1``` and is of type ```INTEGER```. ### Parameter 121: Configure the external switch mode for S2. Configure the external switch mode for S2. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Enter automatic identification mode | | 1 | 2-state switch mode | | 2 | 3 way switch mode | | 3 | Momentary push button mode | The manufacturer defined default value is ```0``` (Enter automatic identification mode). This parameter has the configuration ID ```config_121_1``` and is of type ```INTEGER```. ### Parameter 122: Set the control destination for external switch Set the control destination for external switch The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | control the output loads of itself. | | 2 | control the other nodes | | 3 | control the output loads of itself and other nodes. | The manufacturer defined default value is ```3``` (control the output loads of itself and other nodes.). This parameter has the configuration ID ```config_122_1``` and is of type ```INTEGER```. ### Parameter 252: Lock/unlock configuration parameters Lock/unlock configuration parameters The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Unlock | | 1 | Lock | The manufacturer defined default value is ```0``` (Unlock). This parameter has the configuration ID ```config_252_1``` and is of type ```INTEGER```. ### Parameter 255: Reset the Dual Nano Switch Reset the Dual Nano Switch The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | (Default) Reset all configuration parameters | The manufacturer defined default value is ```0``` ((Default) Reset all configuration parameters). This parameter has the configuration ID ```config_255_4``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The FT132 supports 4 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. When the load state of Dual Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group. Association group 1 supports 5 nodes. ### Group 2: Forward the Basic Set Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group Association group 2 supports 5 nodes. ### Group 3: Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated. Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be Association group 3 supports 5 nodes. ### Group 4: Send Basic Set Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated. Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter Association group 4 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V4| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | ### Documentation Links * [FT140 Manual](https://www.cd-jackson.com/zwave_device_uploads/852/FT140-Dual-Smart-Switch-Manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/852).