--- layout: documentation title: 506219 - ZWave --- {% include base.html %} # 506219 Battery Powered Wall Controller This describes the Z-Wave device *506219*, manufactured by *Merten* with the thing type UID of ```merten_506219_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. The 506219 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview **Single-surface push-button:** Top button: Association Group = 1 Parameter no. = 0 Bottom button: Association Group = 2 Parameter no. = 1 **Dual-surface push-button:** Left top button: Association Group = 1 Parameter no. = 0 Left bottom button: Association Group = 2 Parameter no. = 1 Right top button: Association Group = 3 Parameter no. = 2 Right bottom button: Association Group = 4 Parameter no. = 3 **Transmit "Node info frame"** Triple click on operating surface Wait until the red LED D goes out. Used to identify, associate and configure the device ### Inclusion Information Triple click on operating surface LED flashes approx. 6 seconds. Used for include/exclude the device by the primary ### Wakeup Information The 506219 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. ## Channels The following table summarises the channels available for the 506219 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 7 configuration parameters available in the 506219. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 0 | Switching/dimming/shutters dual-surface: | | | 4 | Switching single-surface | | | 44 | Doorbell function | | | 52 | LOWER shutter as long as button is pressed | | | 54 | Move shutter single-surface | direction of movement changes after each switching process | | 55 | RAISE shutter as long as button is pressed | | | 60 | Retrieve/save scene | | ### Parameter 0: Switching/dimming/shutters dual-surface: Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_0_1``` and is of type ```INTEGER```. ### Parameter 4: Switching single-surface Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 44: Doorbell function Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_44_1``` and is of type ```INTEGER```. ### Parameter 52: LOWER shutter as long as button is pressed Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_52_1``` and is of type ```INTEGER```. ### Parameter 54: Move shutter single-surface direction of movement changes after each switching process Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_54_1``` and is of type ```INTEGER```. ### Parameter 55: RAISE shutter as long as button is pressed Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_55_1``` and is of type ```INTEGER```. ### Parameter 60: Retrieve/save scene Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_60_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 506219 supports 4 association groups. ### Group 1: Left top button Association group 1 supports 1 node. ### Group 2: Left bottom button Association group 2 supports 1 node. ### Group 3: Right top button Association group 3 supports 1 node. ### Group 4: Right bottom button Association group 4 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Merten Connect 506219 Manual](https://www.cd-jackson.com/zwave_device_uploads/323/Merten-Connect-Manual-506219.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/323).