--- layout: documentation title: WS15Z-1 - ZWave --- {% include base.html %} # WS15Z-1 Wall Mounted Switch This describes the Z-Wave device *WS15Z-1*, manufactured by *Linear Corp* with the thing type UID of ```linear_ws15z_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![WS15Z-1 product image](https://www.cd-jackson.com/zwave_device_uploads/4/4_default.jpg) The WS15Z-1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Scene and NWI capable wall mounted switch ### Inclusion Information 1. With your Controller in Discovery or Add Mode, tap the switch once for Network Wide Inclusion. Tap twice for Standard Inclusion. 2. You should see an indication on your Controller that the “device was added” to the network and the LED will stop blinking. ### Exclusion Information 1. Set the Controller into Removal Mode and follow its instruction to delete the WS15Z-1 from the Controller. 2. Remove the switch by tapping the paddle 2 times. 3. You should see an indication on your Controller that the “device was removed” from the network. ## Channels The following table summarises the channels available for the WS15Z-1 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | | Number | | Battery Level | battery-level | Battery | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ## Device Configuration The following table provides a summary of the 2 configuration parameters available in the WS15Z-1. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | Night Light | By default, the LED will turn OFF when the lead attached is turned ON. | | 4 | Invert Switch | To change the top of the switch to OFF and the bottom of the switch ON. | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 3: Night Light By default, the LED will turn OFF when the lead attached is turned ON. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | On when load is on | | 1 | Off when load is on | The manufacturer defined default value is ```1``` (Off when load is on). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Invert Switch To change the top of the switch to OFF and the bottom of the switch ON. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Top-ON, Bottom-OFF | | 1 | Bottom-ON, Top-OFF | The manufacturer defined default value is ```0``` (Top-ON, Bottom-OFF ). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_APPLICATION_STATUS_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/4/WS15Z1-manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/4).